X-ray mirrors for the European Synchrotron Radiation Facility

The present paper outlines the requirements for the performance of x-ray mirrors at the European Synchrotron Radiation Facility (ESRF), to be built in Grenoble, France. It is shown that present-day surface preparation techniques are about adequate to achieve conservation of the source emittance, although some improvements are needed in special cases. It is much harder to conserve brilliance, where thermal deformation is the major obstacle. Here substantial research and development efforts are absolutely indispensable. Two possible ways are indicated to solve the heat problem: cryogenic cooling of silicon-based mirrors and adaptive optical systems. In the first case thermal deformations are drastically reduced, and in the second they can be compensated by mechanical forces. Our results are based on theoretical considerations of scattering by nonideal surfaces and on a thermomechanical analysis, which are also given. For layered synthetic microstructures the technological problems appear to be still more difficult. Because the critical photon energy of the ESRF 6 GeV storage ring and of most of its insertion devices is between 10 and 20 keV or even higher, the discussion is limited to hard x-ray optics.

[1]  P. J. Viccaro,et al.  Performance of multilayers in intense synchrotron x‐ray beams , 1989 .

[2]  Donald H. Bilderback,et al.  The potential of cryogenic silicon and germanium X-ray monochromators for use with large synchrotron heat loads , 1986 .

[3]  H W Schnopper,et al.  Surface correlation function analysis of high resolution scattering data from mirrored surfaces obtained using a triple-axis x-ray diffractometer. , 1988, Applied optics.

[4]  Spectral Analysis Of The Finish Of Diamond-Turned Mirror Surfaces , 1982 .

[5]  Alexei A. Maradudin,et al.  Scattering and absorption of electromagnetic radiation by a semi-infinite medium in the presence of surface roughness , 1975 .

[6]  N. M. Ceglio,et al.  Revolution in x-ray optics. , 1989, Journal of X-ray science and technology.

[7]  C. Boyer,et al.  Adaptive optics for optimization of image resolution. , 1987, Applied optics.

[8]  N. G. Webb,et al.  A focusing monochromator for small-angle diffraction studies with synchrotron radiation , 1977 .

[9]  William Prager,et al.  Theory of Thermal Stresses , 1960 .

[10]  Kwang‐Je Kim,et al.  Characteristics of synchrotron radiation , 1989 .

[11]  P. Dhez,et al.  Tests Of Short Period X-Ray Multilayer Mirrors Using A Position Sensitive Proportional Counter , 1988, Optics & Photonics.

[12]  Werner Jark,et al.  Surface temperature and distortion of optical elements exposed to high power synchrotron radiation beams (invited) , 1989 .

[13]  Stephen D. Fantone,et al.  Highly Polished, Grazing Incidence Mirrors Developed For Synchrotron Radiation Beam Lines At Stanford Synchrotron Radiation Laboratory , 1988 .

[14]  B. Lai,et al.  SHADOW: New developments , 1988 .

[15]  Richard DiGennaro,et al.  Predicting Thermal Distortion of Synchrotron Radiation Mirrors with Finite Element Analysis , 1986, Other Conferences.

[16]  H Hogrefe,et al.  Soft x-ray scattering from rough surfaces: experimental and theoretical analysis. , 1987, Applied optics.

[17]  W. Jark,et al.  Surface temperature and slope errors on plane mirrors exposed to high power synchrotron radiation , 1990 .

[18]  Tetsuya Ishikawa,et al.  Measurement of angle-resolved X-ray scattering from synthetic multilayers , 1986 .

[19]  L. Névot,et al.  Caractérisation des surfaces par réflexion rasante de rayons X. Application à l'étude du polissage de quelques verres silicates , 1980 .

[20]  F. Christensen,et al.  Extreme UV and x-ray scattering measurements from a rough LiF crystal surface characterized by electron micrography. , 1989, Applied optics.

[21]  Finn Erland Christensen,et al.  Measurements Of X-Ray Surface Scattering And Diffraction Properties Of Selected Multilayers , 1988, Optics & Photonics.

[22]  James H. Underwood,et al.  X-ray microprobe using multilayer mirrors , 1988 .

[23]  T. Koetzle,et al.  Optical design for the NSLS crystallography beam line , 1983 .

[24]  A. Freund X-Ray Optics for Synchrotron Radiation , 1989 .

[25]  Lord Rayleigh,et al.  On the Dynamical Theory of Gratings , 1907 .

[26]  E. L. Church,et al.  The Interpretation Of Glancing Incidence Scattering Measurements , 1986, Other Conferences.

[27]  D. Bilderback,et al.  Transmission x-ray mirror — A new optical element , 1982 .

[28]  J. Bordas,et al.  A double focusing X-ray camera for use with synchrotron radiation , 1979 .

[29]  K. Holmes,et al.  Small−angle diffraction of X−rays and the study of biological structures , 1980 .

[30]  F. Merkle Aktive und adaptive Optik in der Astronomie: Neue Technologien für zukünftige Großteleskope , 1988 .

[31]  B. Aschenbach,et al.  X-ray telescopes , 1985 .

[32]  Sirota,et al.  X-ray and neutron scattering from rough surfaces. , 1988, Physical review. B, Condensed matter.

[33]  Hideki Maezawa,et al.  Experimental evaluation of thermal deformation effects of SiC mirror surfaces irradiated by undulator radiation , 1989 .

[34]  Klaus Beckstette Fabrication And Test Of X-Ray Optics , 1989, Other Conferences.