Real-Time Demand Response Through Aggregate Electric Water Heaters for Load Shifting and Balancing Wind Generation

Demand response (DR) has shown to be a promising tool for balancing generation and demand in the future power grid, specifically with high penetration of variable renewable generation, such as wind. This paper evaluates thermostat setpoint control of aggregate electric water heaters (EWHs) for load shifting, and providing desired balancing reserve for the utility. It also assesses the economic benefits of DR for the customers through time-of-use pricing. Simulation results reveal the achievement of the economic benefits to the customers while maintaining their comfort level and providing a large percentage of desired balancing reserve at the presence of wind generation.

[1]  Brock J. LaMeres,et al.  A customer-interactive electric water heater demand-side management strategy using fuzzy logic , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[2]  Thompson Residential Energy Consumption Survey: housing characteristics, 1982 , 1984 .

[3]  D.G. Infield,et al.  Stabilization of Grid Frequency Through Dynamic Demand Control , 2007, IEEE Transactions on Power Systems.

[4]  Alec Brooks,et al.  Demand Dispatch - Using Real-Time Control of Demand to help Balance Generation and Load , 2010 .

[5]  Ning Lu,et al.  Grid FriendlyTM Appliances - Load-side Solution for Congestion Management , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[6]  N. Lu,et al.  Control strategies of thermostatically controlled appliances in a competitive electricity market , 2005, IEEE Power Engineering Society General Meeting, 2005.

[7]  Lennart Söder,et al.  Design and operation of power systems with large amounts of wind power , 2009 .

[8]  Donald J. Hammerstrom,et al.  Grid FriendlyTM Device Model Development and Simulation , 2009 .

[9]  M. O'Malley,et al.  A new approach to quantify reserve demand in systems with significant installed wind capacity , 2005, IEEE Transactions on Power Systems.

[10]  Duncan S. Callaway Tapping the energy storage potential in electric loads to deliver load following and regulation, with application to wind energy , 2009 .

[11]  Yu Zhang,et al.  Design Considerations of a Centralized Load Controller Using Thermostatically Controlled Appliances for Continuous Regulation Reserves , 2013, IEEE Transactions on Smart Grid.

[12]  G. A. Dhomane,et al.  Smart Grid , 2021, Virtual Power Plant System Integration Technology.

[13]  Paul Denholm,et al.  Role of Energy Storage with Renewable Electricity Generation , 2010 .

[14]  Stasha Noelle. Patrick Control of aggregate electric water heaters for load shifting and balancing intermittent renewable energy generation in a smart grid environment , 2011 .

[15]  Weiwei Miao,et al.  Online voltage security assessment considering comfort-constrained demand response control of distributed heat pump systems , 2012 .

[16]  David L. Collins Scald burns from hot tap water , 1982 .

[17]  D. Shively,et al.  Energy Storage Methods for Renewable Energy Integration and Grid Support , 2008, 2008 IEEE Energy 2030 Conference.

[18]  M.H. Nehrir,et al.  Power Management of Aggregate Electric Water Heater Loads by Voltage Control , 2007, 2007 IEEE Power Engineering Society General Meeting.

[19]  Dan Wang,et al.  Comfort-Constrained Distributed Heat Pump Management , 2011 .

[20]  Ning Lu,et al.  An Evaluation of the HVAC Load Potential for Providing Load Balancing Service , 2012, IEEE Transactions on Smart Grid.