Optimization with system damping restoration for droop controlled DC-DC converters

The parallel operation of dc-dc converters is widely used in distribution systems and uninterruptable power supply systems. Droop control along with virtual resistance (VR) is considered a simple and reliable method for achieving wireless power sharing among converters. In order to enhance the efficiency of the conversion system, this paper implements tertiary level optimization control on the basis of hierarchical control. As the efficiency of each converter changes with output power, VRs are set as decision variables for adjusting power sharing proportion among converters. Genetic algorithm is used in searching for global efficiency optimum. However system dynamic is affected when shifting VRs. Therefore, the stability of a parallel buck converter system is analyzed to examine the influence of VR changing on system dynamics. Based on the stability analysis, a system damping secondary restoration (SDSR) is implemented to readjust the optimization results so as to ensure system stability. Simulation results are shown to demonstrate the improvement of system efficiency and effectiveness of the method.

[1]  Juan C. Vasquez,et al.  Hierarchical Control of Droop-Controlled AC and DC Microgrids—A General Approach Toward Standardization , 2009, IEEE Transactions on Industrial Electronics.

[2]  Ali Davoudi,et al.  Hierarchical Structure of Microgrids Control System , 2012, IEEE Transactions on Smart Grid.

[3]  A. Sannino,et al.  Low-Voltage DC Distribution System for Commercial Power Systems With Sensitive Electronic Loads , 2007, IEEE Transactions on Power Delivery.

[4]  B. G. Fernandes,et al.  Modified droop controller for paralleling of dc-dc converters in standalone dc system , 2012 .

[5]  S. Munk-Nielsen,et al.  Comparative study on paralleled vs. scaled dc-dc converters in high voltage gain applications , 2008, 2008 13th International Power Electronics and Motion Control Conference.

[6]  Tianhao Tang,et al.  Efficiency analysis for three phase grid-tied PV inverter , 2008, 2008 IEEE International Conference on Industrial Technology.

[7]  Salman Yussof,et al.  The effect of GA parameters on the performance of GA-based QoS routing algorithm , 2008, 2008 International Symposium on Information Technology.

[8]  Xiaoxiao Yu,et al.  Control of Parallel-Connected Power Converters for Low-Voltage Microgrid—Part I: A Hybrid Control Architecture , 2010, IEEE Transactions on Power Electronics.

[9]  Xinbo Ruan,et al.  DC/DC Conversion Systems Consisting of Multiple Converter Modules: Stability, Control, and Experimental Verifications , 2009, IEEE Transactions on Power Electronics.

[10]  F. Liu,et al.  DC Bus Voltage Control for a Distributed Power System , 2003 .

[11]  John J. Grefenstette,et al.  Optimization of Control Parameters for Genetic Algorithms , 1986, IEEE Transactions on Systems, Man, and Cybernetics.

[12]  Timothy C. Green,et al.  Energy Management System with Stability Constraints for Stand-alone Autonomous Microgrid , 2007, 2007 IEEE International Conference on System of Systems Engineering.