Local Muon Reconstruction in the Drift Tube Detectors

This note describes the local reconstruction in the Drift Tube subdetector of the CMS muon subsystem. The local reconstruction is the sequence of steps leading from the TDC measurements to reconstructed three-dimensional segments inside each DT chamber. These segments are the input to the muon track reconstruction. This note updates and supersedes CMS NOTE 2002/043