Advanced PLL structures for grid synchronization in distributed generation

[1]  A. Sannino,et al.  Improving Voltage Disturbance Rejection for Variable-Speed Wind Turbines , 2002, IEEE Power Engineering Review.

[2]  Poul Ejnar Sørensen,et al.  Mapping of grid faults and grid codes , 2007 .

[3]  B Tomislav Sekara,et al.  Application of the α-approximation for discretization of analogue systems , 2005 .

[4]  Luis Marroyo,et al.  Individual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM , 2008, IEEE Transactions on Industrial Electronics.

[5]  D. Boroyevich,et al.  Double Synchronous Reference Frame PLL for Power Converters Control , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[6]  Marian P. Kazmierkowski,et al.  Control of Three-Level PWM Converter Applied to Variable-Speed-Type Turbines , 2009, IEEE Transactions on Industrial Electronics.

[7]  H. Stemmler,et al.  Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[8]  F. Blaabjerg,et al.  Doubly-Fed Induction Generator Control Under Voltage Sags , 2008, 2008 IEEE Energy 2030 Conference.

[9]  M. Tsili,et al.  CODE REQUIREMENTS FOR LARGE WIND FARMS : A REVIEW OF TECHNICAL REGULATIONS AND AVAILABLE WIND TURBINE TECHNOLOGIES , 2011 .

[10]  Leonardo A. B. Tôrres,et al.  Comparison of Three Single-Phase PLL Algorithms for UPS Applications , 2008, IEEE Transactions on Industrial Electronics.

[11]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[12]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[13]  M. Liserre,et al.  Synchronization methods for three phase distributed power generation systems - An overview and evaluation , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[14]  Roberto Cárdenas,et al.  Sensorless Control of Doubly-Fed Induction Generators Using a Rotor-Current-Based MRAS Observer , 2008, IEEE Transactions on Industrial Electronics.

[15]  Math Bollen,et al.  Mitigation of unbalanced voltage dips using static series compensator , 2003, IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468).

[16]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[17]  Gene F. Franklin,et al.  Digital control of dynamic systems , 1980 .

[18]  M. R. Iravani,et al.  A Nonlinear Adaptive Filter for Online Signal Analysis in Power Systems: Applications , 2002, IEEE Power Engineering Review.

[19]  Sergio Busquets-Monge,et al.  Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[20]  Math Bollen,et al.  Characteristic of voltage dips (sags) in power systems , 2000 .

[21]  S.M. Silva,et al.  PLL structures for utility connected systems , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[22]  Leopoldo García Franquelo,et al.  A Flexible Selective Harmonic Mitigation Technique to Meet Grid Codes in Three-Level PWM Converters , 2007, IEEE Transactions on Industrial Electronics.

[23]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .