Novel mixed fluid cascade natural gas liquefaction process configuration using absorption refrigeration system

Abstract In this study, a novel process configuration for large scale natural gas liquefaction process is introduced and analyzed. This configuration is based on replacement of vapor compression refrigeration cycle by absorption refrigeration system. The required heat duty in the absorption refrigeration system is obtained by available waste heat in the plant. Process simulation is done by Aspen HYSYS software which is a conventional chemical process simulator. Coefficient of performance of the ammonia- water cycle is 0.48. Specific power consumption of the introduced process is 0.172 kWh/kgLNG which shows 30% reduction in the power consumption. The required heat transfer area of the modified process can be decreased up to 31%.

[1]  Mehdi Mehrpooya,et al.  Optimum design of integrated liquid recovery plants by variable population size genetic algorithm , 2010 .

[2]  Mehdi Mehrpooya,et al.  Advanced exergetic analysis of five natural gas liquefaction processes , 2014 .

[3]  Xiongwen Xu,et al.  The correlation between mixed refrigerant composition and ambient conditions in the PRICO LNG process , 2013 .

[4]  M. Mehrpooya,et al.  Energy and exergy analyses of five conventional liquefied natural gas processes , 2014 .

[5]  Chris Underwood,et al.  Thermodynamic analysis of alternative refrigeration cycles driven from waste heat in a food processing application , 2012 .

[6]  Mehdi Mehrpooya,et al.  Introducing a novel integrated NGL recovery process configuration (with a self-refrigeration system (open–closed cycle)) with minimum energy requirement , 2010 .

[7]  Iftekhar A. Karimi,et al.  Optimizing Compressor Operations in an LNG Plant , 2009 .

[8]  Reinhard Radermacher,et al.  Enhancement of APCI cycle efficiency with absorption chillers , 2010 .

[9]  Reinhard Radermacher,et al.  Application of waste heat powered absorption refrigeration system to the LNG recovery process , 2009 .

[10]  S. Chungpaibulpatana,et al.  A review of absorption refrigeration technologies , 2001 .

[11]  Mehdi Mehrpooya,et al.  Exergy analysis of C2+ recovery plants refrigeration cycles , 2008 .

[12]  Mehmet Kanoglu,et al.  Cryogenic turbine efficiencies , 2001 .

[13]  Reinhard Radermacher,et al.  Performance enhancement of propane pre-cooled mixed refrigerant LNG plant , 2012 .

[14]  Iftekhar A. Karimi,et al.  Optimization of Compressor Networks in LNG Operations , 2009 .

[15]  Jianhua Liu,et al.  Thermodynamic and Experimental Analysis of an Ammonia-Water Absorption Chiller , 2010 .

[16]  Ruzhu Wang,et al.  Adsorption refrigeration- : An efficient way to make good use of waste heat and solar energy , 2006 .

[17]  Reinhard Radermacher,et al.  Optimization of propane pre-cooled mixed refrigerant LNG plant , 2011 .

[18]  Judith Gurney BP Statistical Review of World Energy , 1985 .

[19]  Kyu-Yeul Lee,et al.  Determination of the optimal operating conditions of the dual mixed refrigerant cycle for the LNG FPSO topside liquefaction process , 2013, Comput. Chem. Eng..

[20]  Mohammad Hassan Saidi,et al.  Integration of an absorption chiller in a total CHP site for utilizing its cooling production potential based on R-curve concept , 2012 .

[21]  Mehdi Mehrpooya,et al.  Thermoeconomic analysis of a large industrial propane refrigeration cycle used in NGL recovery plant , 2009 .

[22]  G. Venkatarathnam Cryogenic mixed refrigerant processes , 2008 .

[23]  Peter Rodgers,et al.  Gas turbine efficiency enhancement using waste heat powered absorption chillers in the oil and gas industry , 2013 .

[24]  Guangming Chen,et al.  A novel absorption refrigeration cycle for heat sources with large temperature change , 2013 .

[25]  Mehdi Mehrpooya,et al.  A novel process configuration for co-production of NGL and LNG with low energy requirement , 2013 .

[26]  Mahmoud Bourouis,et al.  Analysis of ammonia/water and ammonia/salt mixture absorption cycles for refrigeration purposes in fishing ships , 2014 .

[27]  L. E. Gearhart New glycol-unit design achieves VOC, BTEX reductions , 1998 .

[28]  Mahmoud Reza Pishvaie,et al.  Simulation and exergy‐method analysis of an industrial refrigeration cycle used in NGL recovery units , 2006 .

[29]  Hongguang Jin,et al.  New hybrid absorption–compression refrigeration system based on cascade use of mid-temperature waste heat , 2013 .

[30]  Mehdi Mehrpooya,et al.  Introducing a new parameter for evaluating the degree of integration in cryogenic liquid recovery processes , 2011 .

[31]  Christopher Michael Somers,et al.  Modeling absorption chillers in ASPEN , 2009 .

[32]  B. Brant,et al.  NEW WASTE-HEAT REFRIGERATION UNIT CUTS FLARING, REDUCES POLLUTION , 1998 .

[33]  P. J. Lienau,et al.  Geothermal direct use engineering and design guidebook , 1991 .

[34]  J. C. Bruno,et al.  Improvement of the raw gas drying process in olefin plants using an absorption cooling system driven by quench oil waste heat , 2006 .