Assessment of existing soakaways for reuse

This paper describes a practical approach for the investigation, assessment and design of existing soakaways. This method can be utilised for measuring the performance and capacity of the systems and examining whether the systems are suitable for reuse when information about the design and installation of the systems is not available. The requirements for field observations and the procedure for a soil infiltration test for the installed system are suggested for successful assessment. The soil infiltration rate of the system is estimated from the field test data without requiring information on the design and construction details of the system. The system's working condition is measured by a performance indicator related to the time taken to empty the soakaway. This is then employed to evaluate the potential reuse of the system. The system's drain capacity is determined by the design principles of current practice and the effect of climate change on its drain capacity is considered. Contamination of soils...