New high-power low-distortion synchronous-link-converter VAr compensator

A novel high-power low-distortion static VAr compensator is proposed. The harmonics are eliminated by combining low-frequency high-power devices and high-frequency low-power devices. The effectiveness of the proposed scheme is investigated for a case where it is specifically used for load compensation and also for the case where it is used as a general-purpose VAr generator. A mathematical model of the VAr compensator is presented. Detailed simulation studies of the scheme are provided. Steady-state experimental results obtained from a scaled-down laboratory prototype are provided to demonstrate the viability of the proposed method.

[1]  Fujio Ishiguro,et al.  Development of a large static VAr generator using self-commutated inverters for improving power system stability , 1991 .

[2]  E. J. Stacey,et al.  Advanced state VAr generator employing GTO thyristors , 1988 .

[3]  Laszlo Gyugyi Reactive Power Generation and Control by Thyristor Circuits , 1979 .

[4]  Hirofumi Akagi,et al.  A study of active power filters using quad-series voltage-source PWM converters for harmonic compensation , 1990 .

[5]  Phoivos D. Ziogas,et al.  Analysis and design of a three-phase synchronous solid-state VAr compensator , 1989 .

[6]  Fang Zheng Peng,et al.  Multilevel converters-a new breed of power converters , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[7]  Fang Zheng Peng,et al.  A multilevel voltage-source inverter with separate DC sources for static VAr generation , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[8]  T. S. Lee,et al.  Phenomenon of skipping-sparks in discharges on a dielectric surface , 1994 .

[9]  Y. Sumi,et al.  New Static Var Control Using Force-Commutated Inverters , 1981, IEEE Transactions on Power Apparatus and Systems.

[10]  Geza Joos,et al.  Performance analysis of a PWM inverter VAr compensator , 1991 .

[11]  Hirofumi Akagi,et al.  Analysis and design of a DC voltage-controlled static VAr compensator using quad-series voltage-source inverters , 1996 .

[12]  Hirofumi Akagi,et al.  Control Strategy of Active Power Filters Using Multiple Voltage-Source PWM Converters , 1986, IEEE Transactions on Industry Applications.

[13]  N. S. Choi,et al.  Analysis and controller design of static VAr compensator using three-level GTO inverter , 1996 .

[14]  S.B. Dewan,et al.  A large scale PWM solid state synchronous condenser , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[15]  R. W. Menzies,et al.  Advanced static compensation using a multilevel GTO thyristor inverter , 1995 .

[16]  S. S. Venkata,et al.  The use of decoupled converters to optimize the power electronics of shunt and series AC system controllers , 1997 .