Quenching of biotinylated aequorin bioluminescence by dye-labeled avidin conjugates: application to homogeneous bioluminescence resonance energy transfer assays.

[see reaction]. Avidin conjugates containing the covalently attached dyes QSY-7 and dabcyl were prepared and shown to quench the bioluminescence of biotinylated aequorin. Quenching efficiency was shown to be dependent on both the label-to-avidin ratio and the concentration of the avidin conjugate. These properties were exploited to develop a homogeneous bioluminescence resonance energy transfer (BRET) assay for biotin.

[1]  M. Adamczyk,et al.  Tracermer signal generators: an arborescent approach to the incorporation of multiple chemiluminescent labels. , 1998, Bioorganic & medicinal chemistry letters.

[2]  E. Karplus,et al.  Imaging [Ca2+]i with aequorin using a photon imaging detector. , 1994, Methods in cell biology.

[3]  R. Cummings,et al.  Absorbance- and Light-Based Solid-Phase Assays for CMPNeuAc:Galβ1-4GlcNAc-R α-2,3-Sialyltransferase , 1996 .

[4]  P. Fossier,et al.  Chimeric green fluorescent protein-aequorin as bioluminescent Ca2+ reporters at the single-cell level. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[5]  S Daunert,et al.  Detecting biomolecules in picoliter vials using aequorin bioluminescence. , 1997, Analytical chemistry.

[6]  S. Daunert,et al.  Site-specifically labeled photoprotein-thyroxine conjugates using aequorin mutants containing unique cysteine residues: applications for binding assays (Part II). , 2000, Bioconjugate chemistry.

[7]  O. Shimomura Isolation and properties of various molecular forms of aequorin. , 1986, The Biochemical journal.

[8]  C. Johnson,et al.  A bioluminescence resonance energy transfer (BRET) system: application to interacting circadian clock proteins. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[9]  S. Daunert,et al.  Bioluminescence Binding Assay for Biotin with Attomole Detection Based on Recombinant Aequorin , 1994 .

[10]  T. K. Christopoulos,et al.  Quantitative polymerase chain reaction based on a dual-analyte chemiluminescence hybridization assay for target DNA and internal standard. , 1998, Analytical chemistry.

[11]  T. Hirano,et al.  Shining the light: the mechanism of the bioluminescence reaction of calcium-binding photoproteins. , 1996, Chemistry & biology.

[12]  S. Daunert,et al.  Interaction of immobilized avidin with an aequorin-biotin conjugate: an aequorin-linked assay for biotin. , 1997, Analytical biochemistry.

[13]  S. Daunert,et al.  Heterogeneous bioluminescence binding assay for an octapeptide using recombinant aequorin , 1998 .

[14]  [2] Fluorescence excitation transfer immunoassay (FETI) , 1981 .

[15]  Osamu Shimomura,et al.  The crystal structure of the photoprotein aequorin at 2.3 Å resolution , 2000, Nature.

[16]  T. K. Christopoulos,et al.  Bioluminescence hybridization assays using recombinant aequorin. Application to the detection of prostate-specific antigen mRNA. , 1996, Analytical chemistry.

[17]  M. J. Cormier,et al.  Use of recombinant biotinylated aequorin in microtiter and membrane-based assays: purification of recombinant apoaequorin from Escherichia coli. , 1992, Biochemistry.

[18]  J. Kendall,et al.  Aequorea victoria bioluminescence moves into an exciting new era. , 1998, Trends in biotechnology.

[19]  R. Hunter,et al.  A flash-type bioluminescent immunoassay that is more sensitive than radioimaging: quantitative detection of cytokine cDNA in activated and resting human cells. , 1998, Journal of immunological methods.

[20]  J. Mcghee,et al.  Luminometry: a novel bioluminescent immunoassay enhances the quantitation of mucosal and systemic antibody responses. , 1996, Journal of immunological methods.