Optimal DG Allocation and Thyristor-FCL Controlled Impedance Sizing for Smart Distribution Systems Using Genetic Algorithm

Recently, smart grids have been considered as one of the vital elements in upgrading current power systems to a system with more reliability and efficiency. Distributed generation is necessary for most of these new networks. Indeed, in all cases that DGs are used in distribution systems, protection coordination failures may occur in multiple configurations of smart grids using DGs. In different configurations, there are various fault currents that can lead to protection failure. In this study, an optimal DG locating and Thyristor-Controlled Impedance (TCI) sizing of resistive, inductive, and capacitive type is proposed for distribution systems to prevent considerable changes in fault currents due to different modes of the smart grid. This problem is nonlinear constrained programming (NLP) and the genetic algorithm is utilized for the optimization. This optimization is applied to the IEEE 33-bus and IEEE 69-bus standard distribution systems. Optimum DG location and TCI sizing has carried out in steady fault currents in the grid-connected mode of these practical networks. Simulation results verify that the proposed method is effective for minimizing the protection coordination failure in such distribution networks.

[1]  Hossein Heydari,et al.  An Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques , 2011 .

[2]  H. Nikkhajoei,et al.  Microgrid Protection , 2007, 2007 IEEE Power Engineering Society General Meeting.

[3]  B. Bhattacharyya,et al.  GA based optimal planning of VAR sources using Fast Voltage Stability Index method , 2016 .

[4]  G.T. Heydt,et al.  Fault Current Contribution From Synchronous Machine and Inverter Based Distributed Generators , 2007, IEEE Transactions on Power Delivery.

[5]  Joydeep Mitra,et al.  Microgrid protection using communication-assisted digital relays , 2010, IEEE PES General Meeting.

[6]  A. Y. Chikhani,et al.  Fault-current limiter with thyristor-controlled impedance , 1993 .

[7]  Muhammad Ahsan Zamee,et al.  A new approach for pattern recognition with Neuro-Genetic system using Microbial Genetic Algorithm , 2014, 2014 International Conference on Electrical Engineering and Information & Communication Technology.

[8]  L.A. Kojovic,et al.  Summary of Distributed Resources Impact on Power Delivery Systems , 2008, IEEE Transactions on Power Delivery.

[9]  Javad Sadeh,et al.  Fault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests , 2013 .

[10]  Seyed Abbas Taher,et al.  Optimal location and sizing of DSTATCOM in distribution systems by immune algorithm , 2014 .

[11]  H J Laaksonen,et al.  Protection Principles for Future Microgrids , 2010, IEEE Transactions on Power Electronics.

[12]  A. Yazdian,et al.  Fault current limiter allocation and sizing in distribution system in presence of distributed generation , 2009, 2009 IEEE Power & Energy Society General Meeting.

[13]  T. Kulworawanichpong,et al.  Comparative study on a fault current limiter with thyristor-controlled impedances , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[14]  Dirk Pauschert Study of equipment prices in the power sector , 2009 .

[15]  Steven E. Widergren,et al.  An Orderly Transition to a Transformed Electricity System , 2010, IEEE Transactions on Smart Grid.

[16]  Reza Mohammadi Chabanloo,et al.  Reducing the impact of DG in distribution networks protection using fault current limiters , 2010, 2010 4th International Power Engineering and Optimization Conference (PEOCO).

[17]  A. Yokoyama,et al.  Prevention of Reliability Degradation from Recloser–Fuse Miscoordination Due To Distributed Generation , 2008, IEEE Transactions on Power Delivery.

[18]  Gerard J. M. Smit,et al.  Management and Control of Domestic Smart Grid Technology , 2010, IEEE Transactions on Smart Grid.

[19]  Lidija Petkovska,et al.  Genetic algorithm as a tool for multi-objective optimization of permanent magnet disc motor , 2016 .

[20]  Farshid Keynia,et al.  Short-Term Load Forecast of Microgrids by a New Bilevel Prediction Strategy , 2010, IEEE Transactions on Smart Grid.

[21]  Yi Han,et al.  Study of adaptive fault current algorithm for microgrid dominated by inverter based distributed generators , 2010, The 2nd International Symposium on Power Electronics for Distributed Generation Systems.

[22]  M. Steurer,et al.  Progress on the R&D of fault current limiters for utility applications , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[23]  Dragan S. Popovic,et al.  Advanced fault management as a part of Smart Grid solution , 2008 .

[24]  Arindam Ghosh,et al.  Control and protection of a microgrid with converter interfaced micro sources , 2009, 2009 International Conference on Power Systems.

[25]  Bala Venkatesh,et al.  Optimal Location and Sizing of Fault Current Limiters in Mesh Networks Using Iterative Mixed Integer Nonlinear Programming , 2016, IEEE Transactions on Power Systems.

[26]  T. Jayabarathi,et al.  Multi objective Flower Pollination Algorithm for solving capacitor placement in radial distribution system using data structure load flow analysis , 2016 .

[27]  Ehab F. El-Saadany,et al.  Optimal Sizing of Thyristor-Controlled Impedance for Smart Grids With Multiple Configurations , 2011, IEEE Transactions on Smart Grid.

[28]  T.S. Sidhu,et al.  Restoration of Directional Overcurrent Relay Coordination in Distributed Generation Systems Utilizing Fault Current Limiter , 2008, IEEE Transactions on Power Delivery.

[29]  A.A. Girgis,et al.  Development of adaptive protection scheme for distribution systems with high penetration of distributed generation , 2003, IEEE Transactions on Power Delivery.