Flow visualization in blood aspirator and cardiotomy reservoir used in cardiopulmonary bypass.

OBJECTIVE One of the major damage caused by occlusion in roller pumps is hemolysis. Comparative studies between roller pump with adjustments non occlusive and centrifugal pumps have been made in recent decades in an attempt to develop new products and adjustments that cause fewer traumas to the figurative elements of blood. Usually the roller pumps are adjusted by the static method due to concern variables flow that can occur with non-occlusive settings. Excessive slack in the rollers provoke back flow and can provides errors in the calculation of flow by the rotation of the pump, according to the devices added to the circuit and the systemic resistance of the patient. The objective of this study is to evaluate the back flow caused by two types of roller pumps in blood aspirator and cardiotomy reservoir. METHOD Back flow visualization was performed in blood aspirator and cardiotomy reservoir. It was tested two different models of roller pumps, adjusted by drop rate and dynamic calibration. The tests were conducted with silicone tubes of 3/8 x 1/16 e 1/2 x 3/32 inches in diameter in water and solution similar to blood. RESULTS We recorded back flow visually in blood aspirator and in cardiotomy reservoir with their measure of values. The pumps had differences in refluxes measured adjusted by the dynamic calibration method. Pump#2 presents back flow adjusted fully occluded. CONCLUSION The back flow measured in two models of pump present differences (P <0.008). The results indicate differences in its characteristics caused by the process of manufacturing, design or possible wear. Non-occlusive adjustments may cause variations in flow with the increase of resistance added to the circuit, with difficulty to fix the flow by increasing the rotation.

[1]  T. Aherne,et al.  Differences in displayed pump flow compared to measured flow under varying conditions during simulated cardiopulmonary bypass , 2008, Perfusion.

[2]  L. V. von Segesser,et al.  A novel device for reducing hemolysis provoked by cardiotomy suction during open heart cardiopulmonary bypass surgery: a randomized prospective study. , 2007, Artificial organs.

[3]  Tohru Takaseya,et al.  Non-occlusive condition with the Better-Header roller pump: impacts of flow dynamics and hemolysis. , 2004, Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia.

[4]  D. Sharpe,et al.  Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, nonocclusive roller pumps and centrifugal pumps , 1999, Perfusion.

[5]  M. Oz,et al.  Clinical evaluation of setting pump occlusion by the dynamic method: effect on flow , 1998, Perfusion.

[6]  E. Leonard,et al.  A Dynamic Method for Setting Roller Pumps Nonocclusively Reduces Hemolysis and Predicts Retrograde Flow , 1997, ASAIO journal.

[7]  Clague Ct,et al.  A low-hemolysis blood aspirator conserves blood during surgery. , 1995 .

[8]  P. Blackshear,et al.  An atraumatic aspirator for use in autologous transfusion and cardiac bypass. , 1995, ASAIO journal (1992).

[9]  P. Blackshear,et al.  A low-hemolysis blood aspirator conserves blood during surgery. , 1995, Biomedical Instrumentation & Technology.

[10]  Peter Freymuth,et al.  Flow visualization in fluid mechanics , 1993 .

[11]  J. Soons,et al.  Controlled Cardiotomy Suction during Clinical Bubble Oxygenator Perfusions , 1985, The Thoracic and cardiovascular surgeon.

[12]  L. Edmunds,et al.  Relationship between platelet count and cardiotomy suction return. , 1978, The Annals of thoracic surgery.

[13]  K. Morris,et al.  HEMOLYSIS OF BLOOD IN THE PERICARDIUM: THE MAJOR SOURCE OF PLASMA HEMOGLOBIN DURING TOTAL BODY PERFUSION. , 1965, The Journal of thoracic and cardiovascular surgery.