Cascaded 5-level inverter type DSTATCOM for power quality improvement

In energy transmission systems, effective equipments on power control are generally known as Flexible AC Transmission System (FACTS). In addition, the power electronics-based equipment, which are called power conditioners are use to solve power quality problems. Since the topologies of these equipments are similar to those used in FACTS equipment, power conditioners are also called Distribution FACTS (DFACTS). DSTATCOM is one such power conditioner used for improving power quality. This study proposes a cascaded multilevel inverter type DSTATCOM to compensate voltage sags in utility voltages in power distribution network. The proposed DSTATCOM is implemented using multilevel topology with isolated dc energy storage. The phase shifted PWM technique is described to generate firing pulses to cascaded inverter. The proposed controller adopts itself to the sag and provides effective means of mitigating the voltage sags with the minimum harmonics at the utility end. The proposed concept will be simulated using MATLAB simulink environment. The simulink results will be presented to verify the performance of the proposed multilevel DSTATCOM.

[1]  A. von Jouanne,et al.  Multilevel inverter modulation schemes to eliminate common-mode voltages , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[2]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[3]  R.W. Menzies,et al.  Investigation of a cascade multilevel inverter as an STATCOM , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[4]  Enrique Acha,et al.  Modelling of custom power equipment using harmonic domain techniques , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[5]  I. Wasiak,et al.  Shunt compensation for power quality improvement using a STATCOM controller: modelling and simulation , 2004 .

[6]  Prasad Enjeti,et al.  Analysis of common mode voltage-"neutral shift" in medium voltage PWM adjustable speed drive (MV-ASD) systems , 2000 .

[7]  T.A. Lipo,et al.  Reduced common mode carrier-based modulation strategies for cascaded multilevel inverters , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[8]  Simone Buso,et al.  A dead-beat adaptive hysteresis current control , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).