Biosensor based on enzyme-catalysed degradation of thin polymer films.

A biosensor based on the enzyme-catalysed dissolution of biodegradable polymer films has been developed. Three polymer-enzyme systems were investigated for use in the sensor: a poly(ester amide), which is degraded by the proteolytic enzyme alpha-chymotrypsin; a dextran hydrogel, which is degraded by dextranase; and poly(trimethylene) succinate, which is degraded by a lipase. Dissolution of the polymer films was monitored by Surface Plasmon Resonance (SPR). The rate of degradation was directly related to enzyme concentration for each polymer/enzyme couple. The poly(ester amide)/alpha-chymotrypsin couple proved to be the most sensitive over a concentration range from 4 x 10(-11) to 4 x 10(-7) mol l(-1) of enzyme. The rate of degradation was shown to be independent of the thickness of the poly(ester amide) films. The dextran hydrogel/dextranase couple was less sensitive than the poly(ester amide)/alpha-chymotrypsin couple but showed greater degradation rates at low enzyme concentrations. Enzyme concentrations as low as 2 x 10(-11) mol l(-1) were detected in less than 20 min. Potential fields of application of such a sensor system are the detection of enzyme concentrations and the construction of disposable enzyme based immunosensors, which employ the polymer-degrading enzyme as an enzyme label.

[1]  F. Rowell,et al.  Use of substrate coated electrodes and AC impedance spectroscopy for the detection of enzyme activity , 1998 .

[2]  R. Katsarava,et al.  Heterochain polymers based on natural amino acids. Synthesis and enzymatic hydrolysis of regular poly(ester amide)s based on bis(L-phenylalanine) α,ω-alkylene diesters and adipic acid , 1994 .

[3]  Günter Gauglitz,et al.  Surface plasmon resonance sensors: review , 1999 .

[4]  H. Brøndsted,et al.  Dextran hydrogels for colon-specific drug delivery , 1995 .

[5]  R. Müller,et al.  Enzymatic degradation of a model polyester by lipase from Rhizopus delemar , 1995 .

[6]  I. M. Klotz,et al.  Structural specificities in acylation of hemoglobin and sickle hemoglobin by diaspirins. , 1981, The Journal of biological chemistry.

[7]  H. Brøndsted,et al.  Dextran hydrogels for colon-specific drug delivery. II: Synthesis and characterization , 1995 .

[8]  H. Brøndsted,et al.  Dextran hydrogels for colon-specific drug delivery. III: In vitro and in vivo degradation , 1995 .

[9]  R. Armstrong,et al.  Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation. , 1999, Analytical chemistry.

[10]  S Krause,et al.  A transducer based on enzyme-induced degradation of thin polymer films monitored by surface plasmon resonance. , 2000, Analytical chemistry.

[11]  R. D. Armstrong,et al.  Electrochemical Sensors Based on Impedance Measurement of Enzyme-Catalyzed Polymer Dissolution: Theory and Applications , 1995 .