Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial

BackgroundTo compare the in-the-bag stability and visual function of single-piece intraocular lenses (IOLs) and three-piece IOLs.MethodsA total of 65 patients with age-related cataracts (80 eyes) were enrolled and randomly assigned to receive in-the-bag implantation of either a single-piece IOL (40 eyes) or a three-piece IOL (40 eyes). Follow-up visits were conducted at 1 week, 1 month and 3 months postoperatively. Visual acuity, refraction and total aberration were examined. IOL position stability (including axial movement, decentration and tilt) was measured using a Scheimpflug imaging system.ResultsAt the 3-month follow-up visit, single-piece IOLs did not exhibit significant axial movement (0.07 ± 0.30 mm, p = 0.13) compared with their axial position at 1 week postoperatively, whereas three-piece IOLs displayed forward axial movement of −0.22 ± 0.23 mm (p < 0.0001). The mean manifest spherical equivalence (SE) of eyes with single-piece IOL was 0.15 ± 0.18D, whereas in eyes with three-piece IOLs, the mean manifest SE was −0.34 ± 0.15D (p < 0.001). There was no statistically significant difference in IOL decentration, tilt, uncorrected visual acuity, best-corrected visual acuity or total spherical aberration between the two groups.ConclusionsThree months after implantation, single-piece IOLs exhibit better axial stability and more stable refractive outcome than three-piece IOLs, but both IOLs perform equally well in terms of decentration, tilt, visual acuity and total aberration.Trial registrationClinicalTrial.gov, NCT02609997, 11/18/2015, retrospectively registered.

[1]  Kenneth F Schulz,et al.  For Personal Use. Only Reproduce with Permission from the Lancet Publishing Group. Trialists Rely on the Security of Unpredictability. in the Forcing Cosmetic Credibility Unequal Group Sizes in Randomised Trials: Guarding against Guessing , 2022 .

[2]  F. Mutlu,et al.  Comparison of tilt and decentration of 1‐piece and 3‐piece hydrophobic acrylic intraocular lenses , 2005, Journal of cataract and refractive surgery.

[3]  R. Olson,et al.  A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses. , 2003, American journal of ophthalmology.

[4]  Stephen S Lane,et al.  Comparison of the biomechanical behavior of foldable intraocular lenses , 2004, Journal of cataract and refractive surgery.

[5]  J. Wolffsohn,et al.  Rotational and centration stability of an aspheric intraocular lens with a simulated toric design , 2010, Journal of cataract and refractive surgery.

[6]  T. Oshika,et al.  A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses , 2004, British Journal of Ophthalmology.

[7]  C. McAlinden,et al.  Femtosecond laser cataract surgery , 2015, Eye and Vision.

[8]  Mark Dunne,et al.  Phakometric measurement of ocular surface radius of curvature and alignment: evaluation of method with physical model eyes , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[9]  Susana Marcos,et al.  Intraocular lens alignment from Purkinje and Scheimpflug imaging , 2010, Clinical & experimental optometry.

[10]  Hu Liu,et al.  Increased Difficulties in Managing Stairs in Visually Impaired Older Adults: A Community-Based Survey , 2015, PloS one.

[11]  Susana Marcos,et al.  Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Elie Dolgin,et al.  The myopia boom , 2015, Nature.

[13]  J. Korynta,et al.  Changes in refraction induced by change in intraocular lens position. , 1994, Journal of refractive and corneal surgery.

[14]  C. McGhee,et al.  The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses. , 2011, Ophthalmology.

[15]  J C Barry,et al.  Catoptric properties of eyes with misaligned surfaces studied by exact ray tracing. , 1997, Investigative ophthalmology & visual science.

[16]  Susana Marcos,et al.  Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging: Validation study , 2007, Journal of cataract and refractive surgery.

[17]  Li Wang,et al.  Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. , 2005, Archives of ophthalmology.