A DC-Link Modulation Scheme With Phase-Shifted Current Control for Harmonic Cancellations in Multidrive Applications

This letter proposes a harmonic mitigation strategy to cancel out current harmonics induced by the front-end rectifiers in multidrive systems, which consist of diode rectifiers, silicon-controlled rectifiers (SCR), and boost converters in the dc-link. The proposed strategy is a combination of a new dc-link modulation scheme with a phase-shifted current control enabled by the SCR. The dc-link current modulation scheme is implemented by adding and subtracting specific modulation levels, which makes the total currents drawn from the grid “multilevel,” resulting in an improved current quality. Simulations and experiments have validated the effectiveness of the proposed harmonic mitigation solution for multidrive systems.

[1]  Tore Undeland,et al.  Power Electronics: Converters, Applications and Design , 1989 .

[2]  A. von Jouanne,et al.  Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier type utility interface , 1995 .

[3]  Paul Waide,et al.  Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems , 2011 .

[4]  Johann W. Kolar,et al.  The Essence of Three-Phase PFC Rectifier Systems—Part II , 2013, IEEE Transactions on Power Electronics.

[5]  Peter Steimer High power electronics innovation , 2015, ICPE 2015.

[6]  Hirofumi Akagi,et al.  Active Harmonic Filters , 2005, Proceedings of the IEEE.

[7]  Jung-Ik Ha,et al.  Single-phase active power filtering method using diode-rectifier-fed motor drive , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[8]  Firuz Zare,et al.  Harmonic Analysis of Grid Connected Power Electronic Systems in Low Voltage Distribution Networks , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[9]  T. Friedli,et al.  The Essence of Three-Phase PFC Rectifier Systems—Part I , 2013, IEEE Transactions on Power Electronics.

[10]  Xiong Du,et al.  DC Link Active Power Filter for Three-Phase Diode Rectifier , 2012, IEEE Transactions on Industrial Electronics.

[11]  Firuz Zare A novel harmonic elimination method for a three-phase diode rectifier with controlled DC link current , 2014, 2014 16th International Power Electronics and Motion Control Conference and Exposition.

[12]  F. Blaabjerg,et al.  Harmonic cancellation by mixing nonlinear single-phase and three-phase loads , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[13]  H. Akagi,et al.  A Hybrid Active Filter for a Three-Phase 12-Pulse Diode Rectifier Used as the Front End of a Medium-Voltage Motor Drive , 2012, IEEE Transactions on Power Electronics.

[14]  Frede Blaabjerg,et al.  A novel harmonic elimination approach in three-phase multi-motor drives , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[15]  Yi Zhu,et al.  Load Adaptability of Active Harmonic Reduction for 12-Pulse Diode Bridge Rectifier With Active Interphase Reactor , 2015, IEEE Transactions on Power Electronics.