Experimental Assessment of a Variable Orifice Flowmeter for Respiratory Monitoring
暂无分享,去创建一个
Emiliano Schena | Paola Saccomandi | Carlo Massaroni | Giuseppe Tardi | E. Schena | P. Saccomandi | C. Massaroni | Giuseppe Tardi
[1] Gerald L. Morrison,et al. Response of a slotted orifice flow meter to an air/water mixture , 2001 .
[2] D. Hess,et al. Approaches to Conventional Mechanical Ventilation of the Patient With Acute Respiratory Distress Syndrome , 2011, Respiratory Care.
[3] Peter D. Sly,et al. Measurement of flow and volume , 1996 .
[4] Huibert Burger,et al. Correction factors for oxygen and flow-rate effects on neonatal Fleisch and Lilly pneumotachometers , 2003, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.
[5] Ralph W. Gerard,et al. Methods in medical research , 1967 .
[6] E Schena,et al. A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilation. , 2012, Physiological measurement.
[7] Sergio Silvestri,et al. Non-invasive Estimation of Cardiac Output in Mechanically Ventilated Patients: A Prolonged Expiration Method , 2012, Annals of Biomedical Engineering.
[8] M. Miller,et al. Prevention of thermal and condensation errors in pneumotachographic recordings of the maximal forced expiratory manoeuvre. , 1994, The European respiratory journal.
[9] E. Iso,et al. Measurement Uncertainty and Probability: Guide to the Expression of Uncertainty in Measurement , 1995 .
[10] Stephen B. M. Beck,et al. Experimental study of the pressure drop after fractal-shaped orifices in turbulent pipe flows , 2010 .
[11] D. Thompson,et al. Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick method , 2008, Journal of clinical monitoring and computing.
[12] M. Heulitt,et al. Accuracy of small tidal volume measurement comparing two ventilator airway sensors , 2013, Journal of Pediatric Intensive Care.
[13] Sergio Silvestri,et al. An orifice meter for bidirectional air flow measurements: Influence of gas thermo-hygrometric content on static response and bidirectionality , 2013 .
[14] Richard Plavka,et al. Expired tidal volumes measured by hot‐wire anemometer during high‐frequency oscillation in preterm infants , 2006, Pediatric pulmonology.
[15] D. Baldwin,et al. Optimized temperature and deadspace correction improve analysis of multiple breath washout measurements by ultrasonic flowmeter in infants , 2007, Pediatric pulmonology.
[16] C. K. Yao,et al. Human intestinal gas measurement systems: in vitro fermentation and gas capsules. , 2015, Trends in biotechnology.
[17] Sergio Silvestri,et al. Linearity dependence on oxygen fraction and gas temperature of a novel Fleisch pneumotachograph for neonatal ventilation at low flow rates , 2012 .
[18] Emiliano Schena,et al. Flow measurement in mechanical ventilation: a review. , 2015, Medical engineering & physics.
[19] A. Fleisch. Der Pneumotachograph; ein Apparat zur Geschwindigkeitsregistrierung der Atemluft , 1925, Pflüger's Archiv für die gesamte Physiologie des Menschen und der Tiere.
[20] J. Nunn,et al. Evaluation of metabolic measuring instruments for use in critically ill patients. , 1990, Critical care medicine.
[21] Emiliano Schena,et al. Design and Characterization of a Bidirectional, Low Cost Flowmeter for Neonatal Ventilation , 2014, IEEE Sensors Journal.
[22] Nigel Rankin,et al. Energy balance in the intubated human airway is an indicator of optimal gas conditioning , 2002, Critical care medicine.