Exploring the best predictors of fluid responsiveness in patients with septic shock
暂无分享,去创建一个
Kai Yin | Li Jiang | Degang Yang | Nian-fang Lu | X. Xi
[1] G. Wang,et al. [Measurement of brachial artery velocity variation and inferior vena cava variability to estimate fluid responsiveness]. , 2016, Zhonghua wei zhong bing ji jiu yi xue.
[2] M. Malbrain,et al. Initial resuscitation from severe sepsis: one size does not fit all. , 2015, Anaesthesiology intensive therapy.
[3] S. Magder. Understanding central venous pressure: not a preload index? , 2015, Current opinion in critical care.
[4] Bennett P deBoisblanc,et al. Response to fluid boluses in the fluid and catheter treatment trial. , 2015, Chest.
[5] D. Thévenin,et al. Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†. , 2015, British journal of anaesthesia.
[6] A. Badhe,et al. The comparison of stroke volume variation with central venous pressure in predicting fluid responsiveness in septic patients with acute circulatory failure , 2015, Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine.
[7] J. Diaz-Gomez,et al. Respiratory variation in carotid peak systolic velocity predicts volume responsiveness in mechanically ventilated patients with septic shock: a prospective cohort study , 2015, Critical Ultrasound Journal.
[8] J. Shim,et al. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. , 2014, British journal of anaesthesia.
[9] A. Groeneveld,et al. Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. , 2014, British journal of anaesthesia.
[10] Jami S Smith,et al. Current recommendations for diagnosis and management of sepsis and septic shock , 2013, JAAPA : official journal of the American Academy of Physician Assistants.
[11] Bo Hu,et al. Assessment effect of central venous pressure in fluid resuscitation in the patients with shock: a multi‐center retrospective research , 2013, Chinese medical journal.
[12] C. Sprung,et al. Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock 2012 , 2013, Critical care medicine.
[13] X. Bobbia,et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use , 2012, Critical Care.
[14] M. Wujtewicz. Fluid use in adult intensive care. , 2012, Anaesthesiology intensive therapy.
[15] Qin Gu,et al. [The influence of positive end-expiratory pressure on stroke volume variation for the accuracy of evaluating volume]. , 2012, Zhongguo wei zhong bing ji jiu yi xue = Chinese critical care medicine = Zhongguo weizhongbing jijiuyixue.
[16] Claudio Sandroni,et al. Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis , 2012, Intensive Care Medicine.
[17] S. Tibby,et al. Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children , 2011, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.
[18] M. Cannesson,et al. Monitoring fluid responsiveness. , 2011, Acta anaesthesiologica Taiwanica : official journal of the Taiwan Society of Anesthesiologists.
[19] J. Schefold,et al. Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. , 2010, The Journal of emergency medicine.
[20] F. Saulnier,et al. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis* , 2010, Critical care medicine.
[21] A. Groeneveld. Fluids in septic shock: too much of a good thing? , 2010, Critical care.
[22] A. G. Cano,et al. Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients , 2009 .
[23] M. Kollef,et al. Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study , 2009, Critical care.
[24] Michael Baram,et al. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. , 2008, Chest.
[25] M. Levy,et al. Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock: 2008 , 2007, Intensive Care Medicine.
[26] P. Ray,et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge* , 2007, Critical care medicine.
[27] J. Teboul,et al. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. , 2001, Chest.
[28] Jan de Koning,et al. Relationships between volume and pressure measurements and stroke volume in critically ill patients , 2000, Critical care.
[29] M. Pinsky. Functional haemodynamic monitoring. , 2014, Current opinion in critical care.
[30] R. Dellinger,et al. The Surviving Sepsis Campaign: 2013 and beyond. , 2013, Chinese Medical Journal.
[31] Dellinger Rp. The Surviving Sepsis Campaign: 2013 and beyond. , 2013 .
[32] S. Zanotti-Cavazzoni. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis , 2011 .
[33] D. Fisman,et al. Surviving sepsis? , 2011, The Canadian journal of infectious diseases & medical microbiology = Journal canadien des maladies infectieuses et de la microbiologie medicale.