Combined circuit/device modeling and simulation of integrated microfluidic systems

A combined circuit/device model for the analysis of integrated microfluidic systems is presented. The complete model of an integrated microfluidic device incorporates modeling of fluidic transport, chemical reaction, reagent mixing, and separation. The fluidic flow is generated by an applied electrical field or by a combined electrical field and pressure gradient. In the proposed circuit/device model, the fluidic network has been represented by a circuit model and the functional units of the /spl mu/-TAS (micro Total Analysis System) have been represented by appropriate device models. We demonstrate the integration of the circuit and the device models by using an example, where the output from the fluidic transport module serves as the input for the other modules such as mixing, chemical reaction and separation. The combined circuit/device model can be used for analysis and design of entire microfluidic systems with very little computational expense, while maintaining the desired level of accuracy.

[1]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[2]  B. Weigl,et al.  Lab-on-a-chip for drug development. , 2003, Advanced drug delivery reviews.

[3]  I-Ming Hsing,et al.  Microfabricated PCR-electrochemical device for simultaneous DNA amplification and detection. , 2003, Lab on a chip.

[4]  Armand Ajdari,et al.  Transverse electrokinetic and microfluidic effects in micropatterned channels: lubrication analysis for slab geometries. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[5]  J. Santiago,et al.  Electrokinetic instability micromixing. , 2001, Analytical chemistry.

[6]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[7]  Louisa Alfazema Capillary Electrophoresis: Theory and Practice. P. Camilleri, editor , 2000 .

[8]  A. J. Pfeiffer,et al.  Design and Optimization of Compact Microscale Electrophoretic Separation Systems , 2004 .

[9]  L. Richard Carley,et al.  Table-Based Numerical Macromodeling for MEMS Devices , 2001 .

[10]  Gillian M. Greenway,et al.  Sample manipulation in micro total analytical systems , 2002 .

[11]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[12]  Joel C. Colburn,et al.  Capillary electrophoresis : theory & practice , 1992 .

[13]  J. M. MacInnes,et al.  Computation of reacting electrokinetic flow in microchannel geometries , 2002 .

[14]  H. Becker,et al.  Polymer microfluidic devices. , 2002, Talanta.

[15]  K. Mogensen,et al.  Performance of an in‐plane detection cell with integrated waveguides for UV/Vis absorbance measurements on microfluidic separation devices , 2002, Electrophoresis.

[16]  N. Aubry,et al.  Electroosmotic mixing in microchannels. , 2004, Lab on a chip.

[17]  Gerhard Wachutka,et al.  Microfluidic system modeling using VHDL-AMS and circuit simulation , 1998 .

[18]  T. Kenny,et al.  Electroosmotic capillary flow with nonuniform zeta potential , 2000, Analytical Chemistry.

[19]  Vesselin N. Paunov,et al.  Theoretical considerations of chemical reactions in micro-reactors operating under electroosmotic and electrophoretic control , 1999 .

[20]  G. Whitesides,et al.  Components for integrated poly(dimethylsiloxane) microfluidic systems , 2002, Electrophoresis.

[21]  J. Nutting,et al.  Interfacial Phenomena , 1959, Nature.

[22]  D. J. Harrison,et al.  Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip , 1993, Science.

[23]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[24]  Ring-Ling Chien,et al.  Multiport flow-control system for lab-on-a-chip microfluidic devices , 2001, Fresenius' journal of analytical chemistry.

[25]  Bruce K. Gale,et al.  Electrical conductivity particle detector for use in biological and chemical micro-analysis systems , 1998, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.

[26]  Nickolaj J. Petersen,et al.  Effect of Joule heating on efficiency and performance for microchip‐based and capillary‐based electrophoretic separation systems: A closer look , 2004, Electrophoresis.

[27]  K. Breuer,et al.  Performance and scaling of an electro-osmotic mixer , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[28]  S. Jacobson,et al.  Microfluidic devices for electrokinetically driven parallel and serial mixing , 1999 .

[29]  A. Ewing,et al.  Electroosmotic flow control and monitoring with an applied radial voltage for capillary zone electrophoresis. , 1992, Analytical chemistry.

[30]  W. Ehrfeld Electrochemistry and microsystems , 2003 .

[31]  Xunli Zhang,et al.  Electrokinetic control of a chemical reaction in a lab-on-a-chip micro-reactor: measurement and quantitative modelling. , 2002, Lab on a chip.

[32]  Jörg Peter Kutter,et al.  Current developments in electrophoretic and chromatographic separation methods on microfabricated devices , 2000 .

[33]  R. Mathies,et al.  Radial capillary array electrophoresis microplate and scanner for high-performance nucleic acid analysis. , 1999, Analytical chemistry.

[34]  Rui Qiao,et al.  A compact model for electroosmotic flows in microfluidic devices , 2002 .

[35]  N. Aluru,et al.  Meshless analysis of steady-state electro-osmotic transport , 2000, Journal of Microelectromechanical Systems.

[36]  K. B. Oldham,et al.  Fundamentals of electrochemical science , 1993 .

[37]  E. Norman Lurch Fundamentals of electronics , 1971 .

[38]  Jan Ogrodzki,et al.  Circuit Simulation Methods and Algorithms , 1994 .

[39]  S. Timoshenko,et al.  THEORY OF PLATES AND SHELLS , 1959 .