Cochlear Implant Electrode Effect on Sound Energy Transfer Within the Cochlea During Acoustic Stimulation

Hypothesis: Cochlear implants (CIs) designed for hearing preservation will not alter mechanical properties of the middle and inner ears as measured by intracochlear pressure (PIC) and stapes velocity (Vstap). Background: CIs designed to provide combined electroacoustic stimulation are now available. To maintain functional acoustic hearing, it is important to know if a CI electrode can alter middle or inner ear mechanics because any alteration could contribute to elevated low-frequency thresholds in electroacoustic stimulation patients. Methods: Seven human cadaveric temporal bones were prepared, and pure-tone stimuli from 120 Hz to 10 kHz were presented at a range of intensities up to 110 dB sound pressure level. PIC in the scala vestibuli (PSV) and tympani (PST) were measured with fiber-optic pressure sensors concurrently with VStap using laser Doppler vibrometry. Five CI electrodes from two different manufacturers with varying dimensions were inserted via a round window approach at six different depths (16–25 mm). Results: The responses of PIC and VStap to acoustic stimulation were assessed as a function of stimulus frequency, normalized to sound pressure level in the external auditory canal, at baseline and electrode-inserted conditions. Responses measured with electrodes inserted were generally within approximately 5 dB of baseline, indicating little effect of CI electrode insertion on PIC and VStap. Overall, mean differences across conditions were small for all responses, and no substantial differences were consistently visible across electrode types. Conclusion: Results suggest that the influence of a CI electrode on middle and inner ear mechanics is minimal despite variation in electrode lengths and configurations.

[1]  Stefan Stenfelt,et al.  Fluid volume displacement at the oval and round windows with air and bone conduction stimulation. , 2004, The Journal of the Acoustical Society of America.

[2]  G Jeronimidis,et al.  Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry , 2009, The Journal of Laryngology & Otology.

[3]  Fred F Telischi,et al.  Conservation of Residual Acoustic Hearing After Cochlear Implantation , 2006, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[4]  S. Merchant,et al.  Testing a Method for Quantifying the Output of Implantable Middle Ear Hearing Devices , 2007, Audiology and Neurotology.

[5]  L. Kornreich,et al.  Pattern of hearing loss following cochlear implantation , 2015, European Archives of Oto-Rhino-Laryngology.

[6]  E. Olson,et al.  Observing middle and inner ear mechanics with novel intracochlear pressure sensors. , 1998, The Journal of the Acoustical Society of America.

[7]  T. Lenarz,et al.  European multi-centre study of the Nucleus Hybrid L24 cochlear implant , 2013, International journal of audiology.

[8]  Donald K. Eddington,et al.  Quantitative Evaluation of New Bone and Fibrous Tissue in the Cochlea following Cochlear Implantation in the Human , 2007, Audiology and Neurotology.

[9]  C. Jolly,et al.  Achievement of hearing preservation in the presence of an electrode covering the residual hearing region , 2011, Acta Oto-Laryngologica.

[10]  A. Bozorg Grayeli,et al.  Hearing Preservation after Cochlear Implantation Using Deeply Inserted Flex Atraumatic Electrode Arrays , 2012, Audiology and Neurotology.

[11]  K Gyo,et al.  Measurement of the ossicular vibration ratio in human temporal bones by use of a video measuring system. , 1987, Acta oto-laryngologica.

[12]  A. Eshraghi Prevention of cochlear implant electrode damage , 2006, Current opinion in otolaryngology & head and neck surgery.

[13]  Donald K Eddington,et al.  Analysis of Intracochlear New Bone and Fibrous Tissue Formation in Human Subjects with Cochlear Implants , 2007, The Annals of otology, rhinology, and laryngology.

[14]  Daniel J Tollin,et al.  Effects of Skin Thickness on Cochlear Input Signal Using Transcutaneous Bone Conduction Implants , 2015, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[15]  John J. Rosowski,et al.  Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones , 2009, Journal of the Association for Research in Otolaryngology.

[16]  E W Abel,et al.  Effects of draining cochlear fluids on stapes displacement in human middle-ear models. , 2001, The Journal of the Acoustical Society of America.

[17]  K. Gyo,et al.  Effect of Increased Inner Ear Pressure on Middle Ear Mechanics , 1998, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[18]  H. Eastwood,et al.  Relations between cochlear histopathology and hearing loss in experimental cochlear implantation , 2013, Hearing Research.

[19]  John S. Oghalai,et al.  Predicting the effect of post-implant cochlear fibrosis on residual hearing , 2005, Hearing Research.

[20]  A. Huber,et al.  The Influence of a Cochlear Implant Electrode on the Mechanical Function of the Inner Ear , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[21]  Jan Kiefer,et al.  Development and Evaluation of an Improved Cochlear Implant Electrode Design for Electric Acoustic Stimulation , 2004, The Laryngoscope.

[22]  K. Høgmoen,et al.  Holographic vibration analysis of the ossicular chain. , 1976, Acta oto-laryngologica.

[23]  Thomas Lenarz,et al.  Preservation of residual hearing with cochlear implantation: How and why , 2005, Acta oto-laryngologica.

[24]  K. Koka,et al.  Active Middle Ear Implant Application in Case of Stapes Fixation: A Temporal Bone Study , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[25]  Graeme M Clark,et al.  The multi-channel cochlear implant: Multi-disciplinary development of electrical stimulation of the cochlea and the resulting clinical benefit , 2015, Hearing Research.

[26]  Bruce J Gantz,et al.  Combining acoustic and electrical hearing. , 2003, The Laryngoscope.

[27]  Thomas Lenarz,et al.  Temporal Bone Results and Hearing Preservation with a New Straight Electrode , 2006, Audiology and Neurotology.

[28]  J. Nadol,et al.  Histologic Evaluation of the Tissue Seal and Biologic Response Around Cochlear Implant Electrodes in the Human , 2004, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[29]  Bruce J Gantz,et al.  Speech recognition in noise for cochlear implant listeners: benefits of residual acoustic hearing. , 2004, The Journal of the Acoustical Society of America.

[30]  Elizabeth S. Olson,et al.  Direct measurement of intra-cochlear pressure waves , 1999, Nature.

[31]  Frank Böhnke,et al.  Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrode , 2006, Hearing Research.

[32]  T. Hullar,et al.  Residual Hearing Preservation After Pediatric Cochlear Implantation , 2010, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[33]  J. Nadol,et al.  Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans , 2014, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[34]  K. Koka,et al.  Techniques to Improve the Efficiency of a Middle Ear Implant: Effect of Different Methods of Coupling to the Ossicular Chain , 2013, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[35]  F. Telischi,et al.  Pattern Of Hearing Loss In A Rat Model Of Cochlear Implantation Trauma , 2005, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[36]  Lisa G Potts,et al.  Conductive component after cochlear implantation in patients with residual hearing conservation. , 2014, American journal of audiology.

[37]  Daniel J. Tollin,et al.  Round Window Membrane Implantation with an Active Middle Ear Implant: A Study of the Effects on the Performance of Round Window Exposure and Transducer Tip Diameter in Human Cadaveric Temporal Bones , 2010, Audiology and Neurotology.

[38]  D. Friedland,et al.  Soft Cochlear Implantation: Rationale for the Surgical Approach , 2009, Trends in amplification.

[39]  Stefan Stenfelt,et al.  Round window membrane motion with air conduction and bone conduction stimulation , 2004, Hearing Research.

[40]  C von Ilberg,et al.  Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. , 1999, ORL; journal for oto-rhino-laryngology and its related specialties.

[41]  Kanthaiah Koka,et al.  Vibromechanical Assessment of Active Middle Ear Implant Stimulation in Simulated Middle Ear Effusion: A Temporal Bone Study , 2014, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[42]  Jan Kiefer,et al.  Impact of electrode insertion depth on intracochlear trauma , 2006, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[43]  Kuang-Hua Chang,et al.  Three-dimensional Modeling of Middle Ear Biomechanics and Its Applications , 2002, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[44]  K. Koka,et al.  Sound Location Modulation of Electrocochleographic Responses in Chinchilla With Single-Sided Deafness and Fitted With an Osseointegrated Bone-Conducting Hearing Prosthesis , 2015, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.