An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device

The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We constructed a wideband, ultra-low noise system with a 45 mm diameter superconducting pick-up coil inductively coupled to a current sensor SQUID. Thermal noise in the liquid helium dewar is minimized by using aluminized polyester fabric as superinsulation and aluminum oxide strips as heat shields. With a magnetometer pick-up coil in the center of the Berlin magnetically shielded room 2 (BMSR2), a noise level of around 150 aT Hz−1∕2 is achieved in the white noise regime between about 20 kHz and the system bandwidth of about 2.5 MHz. At lower frequencies, the resolution is limited by magnetic field noise arising from the walls of the shielded room. Modeling the BMSR2 as a closed cube with continuous μ-metal walls, we can quantitatively reproduce its measured field noise.

[1]  H. Meyer,et al.  Nearly quantum limited nanoSQUIDs based on cross-type Nb/AlOx/Nb junctions , 2017, 1705.06166.

[2]  Keiji Enpuku,et al.  SQUIDs in biomagnetism: a roadmap towards improved healthcare , 2016 .

[3]  Dietmar Drung,et al.  A modular, extendible and field-tolerant multichannel vector magnetometer based on current sensor SQUIDs , 2016, 1708.08382.

[4]  L. Trahms,et al.  Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers , 2015, Physics in medicine and biology.

[5]  G. Curio,et al.  Ultra-low-noise EEG/MEG systems enable bimodal non-invasive detection of spike-like human somatosensory evoked responses at 1 kHz , 2015, Physiological measurement.

[6]  Koos C J Zevenhoven,et al.  Current-density imaging using ultra-low-field MRI with zero-field encoding. , 2014, Magnetic resonance imaging.

[7]  A. C. Maloof,et al.  Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer , 2009, 0910.2206.

[8]  S. K. Lee,et al.  Calculation of magnetic field noise from high-permeability magnetic shields and conducting objects with simple geometry , 2007, 0709.2543.

[9]  John Clarke,et al.  SQUID-detected magnetic resonance imaging in microtesla fields. , 2007, Annual review of biomedical engineering.

[10]  D. Drung,et al.  Highly Sensitive and Easy-to-Use SQUID Sensors , 2007, IEEE Transactions on Applied Superconductivity.

[11]  John Clarke,et al.  Calculated signal-to-noise ratio of MRI detected with SQUIDs and Faraday detectors in fields from 10 microT to 1.5 T. , 2007, Journal of magnetic resonance.

[12]  V. Zotev,et al.  SQUID-based instrumentation for ultralow-field MRI , 2007, 0705.0661.

[13]  J. Hutchison,et al.  Liquid helium cryostat for SQUID-based MRI receivers , 2005 .

[14]  Alex I. Braginski,et al.  Fundamentals and technology of SQUIDs and SQUID systems , 2004 .

[15]  Jukka Nenonen,et al.  Thermal Noise in Biomagnetic Measurements , 1993 .

[16]  R. Ilmoniemi,et al.  Sampling theory for neuromagnetic detector arrays , 1993, IEEE Transactions on Biomedical Engineering.

[17]  H. Callen,et al.  Irreversibility and Generalized Noise , 1951 .