Clinical trials in zirconia: a systematic review.

Zirconia is unique in its polymorphic crystalline makeup, reported to be sensitive to manufacturing and handling processes, and there is debate about which processing method is least harmful to the final product. Currently, zirconia restorations are manufactured by either soft or hard-milling processes, with the manufacturer of each claiming advantages over the other. Chipping of the veneering porcelain is reported as a common problem and has been labelled as its main clinical setback. The objective of this systematic review is to report on the clinical success of zirconia-based restorations fabricated by both milling processes, in regard to framework fractures and veneering porcelain chipping. A comprehensive review of the literature was completed for in vivo trials on zirconia restorations in MEDLINE and PubMed between 1950 and 2009. A manual hand search of relevant dental journals was also completed. Seventeen clinical trials involving zirconia-based restorations were found, 13 were conducted on fixed partial dentures, two on single crowns and two on zirconia implant abutments, of which 11 were based on soft-milled zirconia and six on hard-milled zirconia. Chipping of the veneering porcelain was a common occurrence, and framework fracture was only observed in soft-milled zirconia. Based on the limited number of short-term in vivo studies, zirconia appears to be suitable for the fabrication of single crowns, and fixed partial dentures and implant abutments providing strict protocols during the manufacturing and delivery process are adhered to. Further long-term prospective studies are necessary to establish the best manufacturing process for zirconia-based restorations.

[1]  Krister Nilner,et al.  All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial. , 2006, Swedish dental journal.

[2]  C. Marchack,et al.  Customization of milled zirconia copings for all-ceramic crowns: a clinical report. , 2008, The Journal of prosthetic dentistry.

[3]  R. Giordano Materials for chairside CAD/CAM-produced restorations. , 2006, Journal of the American Dental Association.

[4]  Moustafa N. Aboushelib,et al.  Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[5]  P. Rammelsberg,et al.  Fracture-load values of all-ceramic cantilevered FPDs with different framework designs. , 2009, The International journal of prosthodontics.

[6]  L. Lang,et al.  Maxillary zirconia implant fixed partial dentures opposing an acrylic resin implant fixed complete denture: a two-year clinical report. , 2007, The Journal of prosthetic dentistry.

[7]  Anders Ortorp,et al.  A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice. , 2009, Journal of dentistry.

[8]  Ariel J Raigrodski,et al.  Contemporary all-ceramic fixed partial dentures: a review. , 2004, Dental clinics of North America.

[9]  H Fischer,et al.  Lifetime Prediction of All-ceramic Bridges by Computational Methods , 2003, Journal of dental research.

[10]  Jonathan C Knowles,et al.  Fatigue and fracture properties of yttria partially stabilized zirconia crown systems. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[11]  Irena Sailer,et al.  Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function. , 2009, Clinical oral implants research.

[12]  J. J. Mecholsky,et al.  Fracture Surface Analysis of Clinically Failed Fixed Partial Dentures , 2006, Journal of dental research.

[13]  Irena Sailer,et al.  Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. , 2009, Clinical oral implants research.

[14]  Jens Fischer,et al.  Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[15]  J A Tesk,et al.  Failure of All-ceramic Fixed Partial Dentures in vitro and in vivo: Analysis and Modeling , 1995, Journal of dental research.

[16]  A. Čelebić,et al.  Mandibular bone mineral density changes in removable partial denture wearers dependent on the different denture support , 2003 .

[17]  L. Gauckler,et al.  In vitro lifetime of dental ceramics under cyclic loading in water. , 2007, Biomaterials.

[18]  M. Kern,et al.  Osseointegration and clinical success of zirconia dental implants: a systematic review. , 2008, The International journal of prosthodontics.

[19]  J. Schmitt,et al.  Clinical fit of four-unit zirconia posterior fixed dental prostheses. , 2008, European journal of oral sciences.

[20]  D. Edelhoff,et al.  HIP zirconia fixed partial dentures--clinical results after 3 years of clinical service. , 2008, Quintessence international.

[21]  Jens Fischer,et al.  Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[22]  F. Spear Masters of Esthetic Dentistry , 2001 .

[23]  N. Heussen,et al.  Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. , 2008, The International journal of prosthodontics.

[24]  E. D. Rekow,et al.  Fatigue testing of two porcelain-zirconia all-ceramic crown systems. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[25]  L. Gauckler,et al.  Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[26]  M Heller,et al.  Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. , 1989, Journal of biomedical materials research.

[27]  Irena Sailer,et al.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. , 2007, The International journal of prosthodontics.

[28]  I. Denry,et al.  Stabilized zirconia as a structural ceramic: an overview. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[29]  J. Mclean,et al.  The estimation of cement film thickness by an in vivo technique , 1971, British Dental Journal.

[30]  M. Kern,et al.  A new design for all-ceramic inlay-retained fixed partial dentures: a report of 2 cases. , 2006, Quintessence international.

[31]  K. Kobayashi,et al.  Phase change and mechanical properties of ZrO2-Y2O3 solid electrolyte after ageing , 1981 .

[32]  K. Akca,et al.  CAD/CAM ZIRCONIA VS. SLIP-CAST GLASS-INFILTRATED ALUMINA/ZIRCONIA ALL-CERAMIC CROWNS: 2-YEAR RESULTS OF A RANDOMIZED CONTROLLED CLINICAL TRIAL , 2009, Journal of applied oral science : revista FOB.

[33]  N. Götzen,et al.  Influence of Connector Design on Fracture Probability of Ceramic Fixed-partial Dentures , 2002, Journal of dental research.

[34]  R. Crisp,et al.  A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results , 2008, BDJ.

[35]  M V Swain,et al.  Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. , 2009, Acta biomaterialia.

[36]  McLean Jw,et al.  The reinforcement of dental porcelain with ceramic oxides. , 1965 .

[37]  Ariel J Raigrodski,et al.  The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. , 2006, The Journal of prosthetic dentistry.

[38]  M. Schmitter,et al.  Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. , 2009, Journal of oral rehabilitation.

[39]  Ariel J Raigrodski,et al.  Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. , 2004, The Journal of prosthetic dentistry.

[40]  J. J. Mecholsky,et al.  Fractographic analyses of zirconia-based fixed partial dentures. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[41]  M. Schmitter,et al.  All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study. , 2008, Journal of dentistry.

[42]  I. Denry,et al.  State of the art of zirconia for dental applications. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[43]  Michael V Swain,et al.  Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[44]  L. Mancl,et al.  Flexural and shear strengths of ZrO2 and a high-noble alloy bonded to their corresponding porcelains. , 2008, The Journal of prosthetic dentistry.

[45]  D. Edelhoff,et al.  Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) , 2009, Clinical Oral Investigations.

[46]  J. Chevalier,et al.  What future for zirconia as a biomaterial? , 2006, Biomaterials.

[47]  B. Lang,et al.  Shear strength of core-veneer interface in bi-layered ceramics. , 2004, The Journal of prosthetic dentistry.

[48]  M. Norton,et al.  An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. , 1997, Clinical oral implants research.

[49]  L. Gauckler,et al.  Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. , 2006, Quintessence international.

[50]  Josef Schweiger,et al.  High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings--a new fabrication mode for all-ceramic restorations. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[51]  G. Sjögren,et al.  Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[52]  Moustafa N. Aboushelib,et al.  Microtensile bond strength of different components of core veneered all-ceramic restorations. Part 3: double veneer technique. , 2007, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[53]  P Carlson,et al.  All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. , 2005, Journal of oral rehabilitation.

[54]  D. Dunn The use of a zirconia custom implant-supported fixed partial denture prosthesis to treat implant failure in the anterior maxilla: a clinical report. , 2008, The Journal of prosthetic dentistry.

[55]  A. Raigrodski,et al.  Utilization of multiple restorative materials in full-mouth rehabilitation: a clinical report. , 2008, Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.].

[56]  P Schärer,et al.  Zirconia posts: a new all-ceramic concept for nonvital abutment teeth. , 1995, Journal of esthetic dentistry.

[57]  Irena Sailer,et al.  Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. , 2004, The International journal of prosthodontics.

[58]  C. Piconi,et al.  Zirconia as a ceramic biomaterial. , 1999, Biomaterials.

[59]  M. Molin,et al.  Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. , 2008, The International journal of prosthodontics.

[60]  M. Schmitter,et al.  Fracture resistance of the veneering on inlay-retained zirconia ceramic fixed partial dentures , 2005, Acta odontologica Scandinavica.