Assessment of Circumferential Angle Closure with Swept-Source Optical Coherence Tomography: a Community Based Study.

PURPOSE To evaluate the diagnostic performance of swept-source optical coherence tomography (SS-OCT, CASIA SS-1000; Tomey Corporation, Nagoya, Japan) for angle closure detection, in comparison with gonioscopy, in a community setting. DESIGN Reliability analysis. METHODS A total of 2027 phakic subjects aged ≥50 years, with no previous history of glaucoma, laser (including peripheral iridotomy), intraocular surgery, or ocular trauma, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy was performed by a single trained ophthalmologist. SS-OCT angle scans, which obtain radial scans for the entire circumference of the angle, were analyzed by a single examiner, masked to the subject's clinical details. On SS-OCT images, angle closure was defined as contact between the iris and any part of the angle wall anterior to the scleral spur. Different cutoff values of the degree of circumferential angle closure (≥35%, ≥50%, and ≥75%) were taken for analysis to assess SS-OCT performance in detecting angle closure. RESULTS A total of 1857 subjects (91.6%) were included in the final analysis after excluding poor-quality SS-OCT scans. Almost 90% of the subjects were Chinese, with a mean age of 61.8 ± 6.7 years, and more than half were women (63.5%). The overall AUC of SS-OCT manual grading against gonioscopy was 0.84 (95% confidence interval, 0.81-0.88). The prevalence of angle closure on SS-OCT was 26.1% for the ≥35% definition, with an area under the curve of 0.80 (0.77-0.84), sensitivity of 82.5% (75.3%-88.4%), and specificity of 78.5% (76.5%-80.4%). The first-order agreement coefficient statistics for the 2-quadrant gonioscopic definition of angle-closure with corresponding ≥35%, ≥50%, and ≥75% angle closure definitions for SS-OCT were good at 0.89 (0.83-0.93), 0.88 (0.842-0.93), and 0.88 (0.831-0.99), respectively. CONCLUSIONS In this large community-based study, SS-OCT exhibited moderate performance for angle closure detection compared to gonioscopy as the reference standard.

[1]  Mingguang He,et al.  Anterior chamber angle assessment techniques. , 2008, Survey of ophthalmology.

[2]  S. K. Seah,et al.  Screening for narrow angles in the singapore population: evaluation of new noncontact screening methods. , 2008, Ophthalmology.

[3]  Alice Z. Chuang,et al.  Trabecular-Iris Circumference Volume in Open Angle Eyes Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography , 2014, Journal of ophthalmology.

[4]  Tin Aung,et al.  Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure. , 2015, Ophthalmology.

[5]  J. Sommerhalder,et al.  Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure , 2010, Eye.

[6]  Tin Aung,et al.  Swept-source optical coherence tomography assessment of iris–trabecular contact after phacoemulsification with or without goniosynechialysis in eyes with primary angle closure glaucoma , 2015, British Journal of Ophthalmology.

[7]  Tin Aung,et al.  Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography. , 2013, Ophthalmology.

[8]  C. Gatsonis,et al.  Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative , 2003, Clinical chemistry and laboratory medicine.

[9]  D. Friedman,et al.  Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. , 2008, Ophthalmology.

[10]  Shan C. Lin,et al.  Anterior segment optical coherence tomography as a screening tool for the assessment of the anterior segment angle. , 2009, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[11]  J. Reitsma,et al.  Diagnostic methods I: sensitivity, specificity, and other measures of accuracy. , 2009, Kidney international.

[12]  Shu Liu,et al.  Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement. , 2011, Investigative ophthalmology & visual science.

[13]  Lauren S Blieden,et al.  Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography. , 2016, American journal of ophthalmology.

[14]  D. Friedman,et al.  Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. , 2007, Ophthalmology.

[15]  Tin Aung,et al.  Assessment of the scleral spur in anterior segment optical coherence tomography images. , 2008, Archives of ophthalmology.

[16]  Tin Aung,et al.  Swept source optical coherence tomography measurement of the iris–trabecular contact (ITC) index: a new parameter for angle closure , 2013, Graefe's Archive for Clinical and Experimental Ophthalmology.