Empirical projection-based basis-component decomposition method

Advances in the development of semiconductor based, photon-counting x-ray detectors stimulate research in the domain of energy-resolving pre-clinical and clinical computed tomography (CT). For counting detectors acquiring x-ray attenuation in at least three different energy windows, an extended basis component decomposition can be performed in which in addition to the conventional approach of Alvarez and Macovski a third basis component is introduced, e.g., a gadolinium based CT contrast material. After the decomposition of the measured projection data into the basis component projections, conventional filtered-backprojection reconstruction is performed to obtain the basis-component images. In recent work, this basis component decomposition was obtained by maximizing the likelihood-function of the measurements. This procedure is time consuming and often unstable for excessively noisy data or low intrinsic energy resolution of the detector. Therefore, alternative procedures are of interest. Here, we introduce a generalization of the idea of empirical dual-energy processing published by Stenner et al. to multi-energy, photon-counting CT raw data. Instead of working in the image-domain, we use prior spectral knowledge about the acquisition system (tube spectra, bin sensitivities) to parameterize the line-integrals of the basis component decomposition directly in the projection domain. We compare this empirical approach with the maximum-likelihood (ML) approach considering image noise and image bias (artifacts) and see that only moderate noise increase is to be expected for small bias in the empirical approach. Given the drastic reduction of pre-processing time, the empirical approach is considered a viable alternative to the ML approach.

[1]  Deborah Walter,et al.  Dual kVp material decomposition using flat-panel detectors , 2004, SPIE Medical Imaging.

[2]  Feng Zhang,et al.  Dual-energy x-ray image decomposition by independent component analysis , 2001, International Symposium on Multispectral Image Processing and Pattern Recognition.

[3]  Katsuyuki Taguchi,et al.  Microcomputed tomography with a photon-counting x-ray detector , 2007, SPIE Medical Imaging.

[4]  Yong Du,et al.  Investigation of the use of photon counting x-ray detectors with energy discrimination capability for material decomposition in micro-computed tomography , 2007, SPIE Medical Imaging.

[5]  J. H. Hubbell,et al.  XCOM: Photon cross sections on a personal computer , 1987 .

[6]  Bruno De Man,et al.  An outlook on x-ray CT research and development. , 2008, Medical physics.

[7]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[8]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[9]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[10]  G. Barnes,et al.  Semiempirical model for generating tungsten target x-ray spectra. , 1991, Medical physics.

[11]  W. Kalender,et al.  Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[12]  Katsuyuki Taguchi,et al.  Image-domain material decomposition using photon-counting CT , 2007, SPIE Medical Imaging.

[13]  James A. Scott Photon, Electron, Proton and Neutron Interaction Data for Body Tissues ICRU Report 46. International Commission on Radiation Units and Measurements, Bethesda, 1992, $40.00 , 1993 .

[14]  J. H. Hubbell,et al.  XCOM: Photon Cross Section Database (version 1.2) , 1999 .

[15]  Katsuyuki Taguchi,et al.  A Poisson likelihood iterative reconstruction algorithm for material decomposition in CT , 2007, SPIE Medical Imaging.

[16]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[17]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.