Optimum Subcutaneous Glucose Sampling and Fourier Analysis of Continuous Glucose Monitors

Background: The objective of this article was to focus on the application of harmonic decomposition to continuous glucose monitor (CGM) measurements. We show evidence of an attenuation of fast variations of interstitial glucose when compared to blood in type 1 diabetes mellitus (T1DM) and, using information theory, propose optimal sampling schedules associated with the use and study of CGMs. Method: Using a cohort of 26 T1DM subjects, wearing two Navigator™ sensors for 1 to 3 days, we analyzed the frequency content of each glucose signal and derived across subject frequency cutoffs using discrete Fourier transform and common signal processing techniques. Results: We observed a significant difference in the frequency content of blood glucose compared to interstitial glucose in T1DM, providing evidence toward the existence of a diffusion process between blood and interstitial glucose, acting as a low-pass filter. Furthermore, we obtained a 15-minutes sampling schedule for optimal comparison of CGM values to blood reference. Conclusion: Blood glucose and interstitial glucose have different dynamics, as shown by harmonic analysis, and these differences have consequences on advisable schedules for accuracy studies of CGMS.

[1]  V. Brodan,et al.  Analysis of rapid oscillations of glucose and free fatty acids in plasma , 1979, European Journal of Applied Physiology and Occupational Physiology.

[2]  William L Clarke,et al.  Modeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp , 2007, Journal of diabetes science and technology.

[3]  Tatyana P. Denisova,et al.  Spectral analysis of time functions of plasma glucose and immunoreactive insulin during intravenous glucose tolerance testing on atherosclerosis and noninsulin-dependent diabetes mellitus , 2000, Saratov Fall Meeting.

[4]  B. Ionescu,et al.  FFT analysis and periodic function regression of glycemia time fluctuations in diabetes , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  J. Mastrototaro,et al.  The MiniMed continuous glucose monitoring system. , 2000, Diabetes technology & therapeutics.

[6]  Daniel J Cox,et al.  Methods for quantifying self-monitoring blood glucose profiles exemplified by an examination of blood glucose patterns in patients with type 1 and type 2 diabetes. , 2002, Diabetes technology & therapeutics.

[7]  G. Steil,et al.  Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. , 1999, The American journal of physiology.

[8]  Joost B L Hoekstra,et al.  Relationship between interstitial and blood glucose in type 1 diabetes patients: delay and the push-pull phenomenon revisited. , 2007, Diabetes technology & therapeutics.

[9]  J. Mastrototaro,et al.  The MiniMed Continuous Glucose Monitoring System (CGMS). , 1999, Journal of pediatric endocrinology & metabolism : JPEM.

[10]  C. Shannon,et al.  Communication In The Presence Of Noise , 1998, Proceedings of the IEEE.

[11]  I. Hirsch,et al.  Should minimal blood glucose variability become the gold standard of glycemic control? , 2005, Journal of diabetes and its complications.

[12]  David A. Gough,et al.  Frequency Characterization of Blood Glucose Dynamics , 2004, Annals of Biomedical Engineering.

[13]  R. Potts,et al.  Physiological differences between interstitial glucose and blood glucose measured in human subjects. , 2003, Diabetes care.

[14]  D. Klonoff Continuous glucose monitoring: roadmap for 21st century diabetes therapy. , 2005, Diabetes care.

[15]  Boris Kovatchev,et al.  Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors , 2008, Journal of diabetes science and technology.

[16]  Boris P Kovatchev,et al.  Is glycemic variability important to assessing antidiabetes therapies? , 2006, Current diabetes reports.

[17]  S. O’Rahilly,et al.  Impaired pulsatile secretion of insulin in relatives of patients with non-insulin-dependent diabetes. , 1988, The New England journal of medicine.

[18]  C.E. Shannon,et al.  Communication in the Presence of Noise , 1949, Proceedings of the IRE.

[19]  R. Bertram,et al.  Metabolic and electrical oscillations: partners in controlling pulsatile insulin secretion. , 2007, American journal of physiology. Endocrinology and metabolism.

[20]  Michael Miller,et al.  Use of Fourier Models for Analysis and Interpretation of Continuous Glucose Monitoring Glucose Profiles , 2007, Journal of diabetes science and technology.

[21]  P. Jansson,et al.  Characterization by microdialysis of intracellular glucose level in subcutaneous tissue in humans. , 1988, The American journal of physiology.