Stereotactic Brain Biopsy With a Low-Field Intraoperative Magnetic Resonance Imager

BACKGROUND: Techniques for stereotactic brain biopsy have evolved in parallel with the imaging modalities used to visualize the brain. OBJECTIVE: To describe our technique for performing stereotactic brain biopsy using a compact, low-field, intraoperative magnetic resonance imager (iMRI). METHODS: Thirty-three patients underwent stereotactic brain biopsies with the PoleStar N-20 iMRI system (Medtronic Navigation, Louisville, Colorado). Preoperative iMRI scans were obtained for biopsy target identification and trajectory planning. A skull-mounted device (Navigus, Medtronic Navigation) was used to guide an MRI-compatible cannula to the target. An intraoperative image was acquired to confirm accurate cannula placement within the lesion. Serial images were obtained to track cannula movement and to rule out hemorrhage. Frozen sections were obtained in all but 1 patient with a brain abscess. RESULTS: Diagnostic tissue was obtained in 32 of 33 patients. In all cases, imaging demonstrated cannula placement within the lesion. Histological diagnoses included 22 primary brain tumors and 10 nonneoplastic lesions. In 61% of the cases, initial trajectory was corrected on the basis of the intraoperative scans. In 1 patient, biopsy was nondiagnostic despite accurate cannula placement. No patient suffered a clinically or radiographically significant hemorrhage during or after surgery. There were no intraoperative complications. CONCLUSION: Stereotactic biopsy with a low-field iMRI is an accurate way to obtain specimens with a high diagnostic yield. This accuracy, combined with the acceptable additional procedural time, may obviate the need for frozen section. The ability to correct biopsy cannula placement during surgery eliminates the chance of misdiagnosis because of faulty targeting, as well as the risks associated with inconclusive frozen sections and “blind” replacement of the cannula.

[1]  W. Hall,et al.  Targeted brain biopsy: a comparison of freehand computed tomography-guided and stereotactic techniques. , 1993, Neurosurgery.

[2]  W. Hall,et al.  Brain biopsy sampling by using prospective stereotaxis and a trajectory guide. , 2001, Journal of neurosurgery.

[3]  Michael A Vogelbaum,et al.  Intracranial navigation by using low-field intraoperative magnetic resonance imaging: preliminary experience. , 2002, Journal of neurosurgery.

[4]  S. Salas,et al.  Stereotactic Accuracy of a Compact Intraoperative MRI System , 2006, Stereotactic and Functional Neurosurgery.

[5]  R. Kikinis,et al.  Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. , 1997, Neurosurgery.

[6]  Alessandro Olivi,et al.  Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. , 2006, Journal of neurosurgery.

[7]  N. Dorward,et al.  Clinical Validation of True Frameless Stereotactic Biopsy: Analysis of the First 125 Consecutive Cases , 2001, Neurosurgery.

[8]  W. Hall The safety and efficacy of stereotactic biopsy for intracranial lesions , 1998, Cancer.

[9]  W. Hall,et al.  Intraoperative Magnetic Resonance Imaging-Guided Neurosurgery , 2003 .

[10]  W. Hall,et al.  Improving diagnostic yield in brain biopsy: Coupling spectroscopic targeting with real‐time needle placement , 2001, Journal of magnetic resonance imaging : JMRI.

[11]  S. Kollias,et al.  Histological yield, complications, and technological considerations in 114 consecutive frameless stereotactic biopsy procedures aided by open intraoperative magnetic resonance imaging. , 2002, Journal of neurosurgery.

[12]  Walter A. Hall,et al.  3-Tesla intraoperative MR imaging for neurosurgery , 2006, Journal of Neuro-Oncology.

[13]  J. Torner,et al.  Computed imaging-assisted stereotactic brain biopsy: a risk analysis of 225 consecutive cases. , 1998, Surgical neurology.

[14]  R. Bernays,et al.  Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery. , 1997, Neurosurgery.

[15]  C. Nimsky,et al.  Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report. , 1998, Neurosurgery.

[16]  F A Jolesz,et al.  Frameless Stereotactic Neurosurgery Using Intraoperative Magnetic Resonance Imaging: Stereotactic Brain Biopsy , 2000, Neurosurgery.

[17]  Michael Schulder,et al.  Cranial surgery with an expanded compact intraoperative magnetic resonance imager. Technical note. , 2006, Journal of neurosurgery.

[18]  Walter A Hall,et al.  Intraoperative Magnetic Resonance Imaging-guided neurosurgery at 3-T , 2006, Neurosurgery.

[19]  W. Hall,et al.  Navigus trajectory guide. , 2000, Neurosurgery.

[20]  W. Hall,et al.  Brain biopsy using high-field strength interventional magnetic resonance imaging. , 1999, Neurosurgery.

[21]  W Kucharczyk,et al.  Brain tumor surgery with the Toronto open magnetic resonance imaging system: preliminary results for 36 patients and analysis of advantages, disadvantages, and future prospects. , 2000, Neurosurgery.