Magnetic shape anisotropy effect on sensing performance and directional sensitivity in magnetostrictive nickel patch transducer

This article presents the magnetic shape anisotropy effect on sensing performance and directional sensitivity in a directional magnetostrictive patch transducer using a uniaxial comb-shaped nickel patch, for the use of ultrasonic guided Lamb wave technology in metallic planar structure. The uniaxial comb patch was modified from a disc-shaped patch made of polycrystalline nickel, so that its comb fingers were aligned to a specific radial direction to promote the magnetic shape anisotropy in the nickel patch. Previously, it was found that a magnetostrictive patch transducer using a nickel disc patch appeared to have omnidirectional sensitivity for sensing guided Lamb waves in an aluminum plate due to the isotropic magnetostrictive nature of polycrystalline nickel. In this work, we initially investigated a theoretical approach to determine demagnetization factor change caused by the geometrical shape modification of a nickel patch, which strongly correlated with a specific magnetization characteristic of the patch. Then, experimental guided Lamb wave analysis was followed to demonstrate the directional guided Lamb wave sensitivity of magnetostrictive patch transducers using nickel patches with three different geometrical configurations. We verified from the experimental guided Lamb wave testing that the proposed magnetostrictive patch transducer using the uniaxial comb-shaped nickel patch exhibited excellent directional sensitivity along the comb fingers’ orientation in the aluminum plate.

[1]  Alison B. Flatau,et al.  Directional magnetostrictive patch transducer based on Galfenol’s anisotropic magnetostriction feature , 2014 .

[2]  Alison B. Flatau,et al.  Galfenol-based directional magnetostrictive patch transducer for guided Lamb wave techniques , 2014, Smart Structures.

[3]  S. Na,et al.  Global Goss grain growth and grain boundary characteristics in magnetostrictive Galfenol sheets , 2013 .

[4]  Y. Kim,et al.  Omnidirectional lamb waves by axisymmetrically-configured magnetostrictive patch transducer , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[5]  Hoon Sohn,et al.  Complete noncontact laser ultrasonic imaging for automated crack visualization in a plate , 2013 .

[6]  M. Yan,et al.  Domain rotation simulation of anisotropic magnetostrictions in giant magnetostrictive materials , 2011 .

[7]  Joseph L. Rose,et al.  The upcoming revolution in ultrasonic guided waves , 2011, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[8]  Lingyu Yu,et al.  Shear lag solution for tuning ultrasonic piezoelectric wafer active sensors with applications to Lamb wave array imaging , 2010 .

[9]  P. Wilcox,et al.  Evaluation of the damage detection capability of a sparse-array guided-wave SHM system applied to a complex structure under varying thermal conditions , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Seung Hyun Cho,et al.  Beam-focused shear-horizontal wave generation in a plate by a circular magnetostrictive patch transducer employing a planar solenoid array , 2008 .

[11]  K. Balasubramaniam,et al.  SHM of pipes using torsional waves generated by in situ magnetostrictive tapes , 2007 .

[12]  T. Michaels,et al.  Guided wave signal processing and image fusion for in situ damage localization in plates , 2007 .

[13]  Carlos E. S. Cesnik,et al.  Review of guided-wave structural health monitoring , 2007 .

[14]  Seung-Hyun Cho,et al.  Guided wave transduction experiment using a circular magnetostrictive patch and a figure-of-eight coil in nonferromagnetic plates , 2006 .

[15]  Hegeon Kwun,et al.  Magnetostrictive Sensor for Generating and Detecting Plate Guided Waves , 2005 .

[16]  Seung Hyun Cho,et al.  Torsional wave experiments with a new magnetostrictive transducer configuration. , 2005, The Journal of the Acoustical Society of America.

[17]  Chun H. Wang,et al.  A synthetic time-reversal imaging method for structural health monitoring , 2004 .

[18]  Sridhar Krishnaswamy,et al.  Interaction of a scanning laser-generated ultrasonic line source with a surface-breaking flaw. , 2004, The Journal of the Acoustical Society of America.

[19]  Jan Drewes Achenbach,et al.  Laser excitation of surface wave motion , 2003 .

[20]  Victor Giurgiutiu,et al.  Lamb wave generation with piezoelectric wafer active sensors for structural health monitoring , 2003, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[21]  Amikam Aharoni,et al.  Demagnetizing factors for rectangular ferromagnetic prisms , 1998 .

[22]  P. Wilcox,et al.  Flexible interdigital PVDF transducers for the generation of Lamb waves in structures , 1997 .

[23]  S. Krishnaswamy,et al.  EMAT Generation and Laser Detection of Single Lamb Wave Modes , 1997 .

[24]  P. Cawley,et al.  The use of Lamb waves for the long range inspection of large structures , 1996 .

[25]  S. Egusa,et al.  Piezoelectric paints: preparation and application as built-in vibration sensors of structural materials , 1993, Journal of Materials Science.

[26]  R. B. Thompson Physical Principles of Measurements with EMAT Transducers , 1990 .

[27]  E. Schlömann,et al.  Demagnetizing Field in Nonellipsoidal Bodies , 1965 .