Finite element study of controlling factors of anterior intrusion and torque during Temporary Skeletal Anchorage Device (TSAD) dependent en masse retraction without posterior appliances: Biocreative hybrid retractor (CH-retractor).

OBJECTIVES To evaluate, using the finite element method (FEM), the factors that allow control of the anterior teeth during en masse retraction with the Biocreative hybrid retractor (CH-retractor) using different sizes of nickel-titanium (NiTi) archwires and various gable bends on the stainless-steel (SS) archwires. MATERIALS AND METHODS Using FEM, the anterior archwire section, engaged on the anterior dentition, was modeled in NiTi, and another assembly, the posterior guiding archwire, was modeled in SS. Two dimensions (0.016 × 0.022- and 0.017 × 0.025-inch NiTi) of the anterior archwires and different degrees (0°, 15°, 30°, 45°, and 60°) of the gable bends on the guiding wire were applied to the CH-retractor on the anterior segment to evaluate torque and intrusion with 100-g retraction force to TSADs. Finite element analysis permitted sophisticated analysis of anterior tooth displacement. RESULTS With a 0° gable bend all anterior teeth experienced extrusion. The canines showed a larger amount of extrusion than did the central and lateral incisors. With a gable bend of >15°, all anterior teeth exhibited intrusion. Bodily movement of the central incisor required a 30°∼45° gable bend when using anterior segments of 0.016 × 0.022-inch NiTi and 15°∼30° gable bend with the 0.017 × 0.025-inch NiTi. CONCLUSIONS With the CH-retractor, varying the size of the NiTi archwire and/or varying the amount of gable bend on the SS archwire affects control of the anterior teeth during en masse retraction without a posterior appliance.

[1]  Sunock Yun,et al.  Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element study , 2019, Korean journal of orthodontics.

[2]  Min-Ki Noh,et al.  The biocreative strategy. Part 5: Labial and lingual space closure in extraction treatment. , 2018, Journal of clinical orthodontics : JCO.

[3]  Gerald Nelson,et al.  The biocreative strategy: Part 1 foundations. , 2018, Journal of clinical orthodontics : JCO.

[4]  Seong-Hun Kim,et al.  En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding , 2014, Korean journal of orthodontics.

[5]  Seong-Hun Kim,et al.  Atypical orthodontic extraction pattern managed by differential en-masse retraction against a temporary skeletal anchorage device in the treatment of bimaxillary protrusion. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[6]  Y. Chun,et al.  Factors controlling anterior torque during C-implant-dependent en-masse retraction without posterior appliances. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[7]  Seong-Hun Kim,et al.  Analysis of temporary skeletal anchorage devices used for en-masse retraction: a preliminary study. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[8]  Seong-Hun Kim,et al.  Severe bidentoalveolar protrusion treated with orthodontic microimplant-dependent en-masse retraction. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[9]  L Keilig,et al.  Numerical simulation of the biomechanical behaviour of multi-rooted teeth. , 2005, European journal of orthodontics.

[10]  Christoph Bourauel,et al.  Determination of the Elasticity Parameters of the Human Periodontal Ligament and the Location of the Center of Resistance of Single-rooted Teeth A Study of Autopsy Specimens and Their Conversion into Finite Element Models , 2002, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.

[11]  R J Isaacson,et al.  Three biologic variables modifying faciolingual tooth angulation by straight-wire appliances. , 1989, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[12]  L. Andrews Straight wire : the concept and appliance , 1989 .

[13]  C J Burstone,et al.  Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces. , 1987, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[14]  P L Block,et al.  Restorative margins and periodontal health: a new look at an old perspective. , 1987, The Journal of prosthetic dentistry.

[15]  E. D. Coolidge The Thickness of the Human Periodontal Membrane , 1937 .

[16]  R. Kronfeld Histologic Study of the Influence of Function on the Human Periodontal Membrane , 1931 .

[17]  Seong-Hun Kim,et al.  Anterior torque control using partial-osseointegrated mini-implants: biocreative therapy type I technique. , 2008, World journal of orthodontics.

[18]  Seong-Hun Kim,et al.  Unusual extraction treatment in Class II division 1 using C-orthodontic mini-implants. , 2007, The Angle orthodontist.