Introducing Augmented Reality to Optical Coherence Tomography in Ophthalmic Microsurgery

Augmented Reality (AR) in microscopic surgery has been subject of several studies in the past two decades. Nevertheless, AR has not found its way into everyday microsurgical workflows. The introduction of new surgical microscopes equipped with Optical Coherence Tomography (OCT) enables the surgeons to perform multimodal (optical and OCT) imaging in the operating room. Taking full advantage of such elaborate source of information requires sophisticated intraoperative image fusion, information extraction, guidance and visualization methods. Medical AR is a unique approach to facilitate utilization of multimodal medical imaging devices. Here we propose a novel medical AR solution to the long-known problem of determining the distance between the surgical instrument tip and the underlying tissue in ophthalmic surgery to further pave the way of AR into the surgical theater. Our method brings augmented reality to OCT for the first time by augmenting the surgeon's view of the OCT images with an estimated instrument cross-section shape and distance to the retinal surface using only information from the shadow of the instrument in intraoperative OCT images. We demonstrate the applicability of our method in retinal surgery using a phantom eye and evaluate the accuracy of the augmented information using a micromanipulator.

[1]  Patrick S. Jensen,et al.  Surgical Forces and Tactile Perception During Retinal Microsurgery , 1999, MICCAI.

[2]  J. Berger,et al.  Computer-vision-enabled augmented reality fundus biomicroscopy. , 1999, Ophthalmology.

[3]  David J. Hawkes,et al.  Design and evaluation of a system for microscope-assisted guided interventions (MAGI) , 1999, IEEE Transactions on Medical Imaging.

[4]  Joel S. Schuman,et al.  Ophthalmic surgery, lasers & imaging: The official journal of the International Society for Imaging in the Eye , 2003 .

[5]  Maciej Wojtkowski,et al.  Retinal assessment using optical coherence tomography , 2006, Progress in Retinal and Eye Research.

[6]  U. Schmidt-Erfurth,et al.  Automatic segmentation in three-dimensional analysis of fibrovascular pigmentepithelial detachment using high-definition optical coherence tomography , 2007, British Journal of Ophthalmology.

[7]  Wolfgang Drexler,et al.  State-of-the-art retinal optical coherence tomography , 2008, Progress in Retinal and Eye Research.

[8]  N. Navab,et al.  Advanced Medical Displays: A Literature Review of Augmented Reality , 2008, Journal of Display Technology.

[9]  Russell H. Taylor,et al.  Intraoperative Visualization of Anatomical Targets in Retinal Surgery , 2008, 2008 IEEE Workshop on Applications of Computer Vision.

[10]  Ramiro S. Maldonado,et al.  The use of optical coherence tomography in intraoperative ophthalmic imaging. , 2011, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[11]  Sina Farsiu,et al.  Integration of a spectral domain optical coherence tomography system into a surgical microscope for intraoperative imaging. , 2011, Investigative ophthalmology & visual science.

[12]  Susanne Binder,et al.  FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY , 2011, Retina.

[13]  Lejing Wang,et al.  First Deployments of Augmented Reality in Operating Rooms , 2012, Computer.

[14]  Russell H. Taylor,et al.  Vision-Based Proximity Detection in Retinal Surgery , 2012, IEEE Transactions on Biomedical Engineering.

[15]  Oliver Findl,et al.  Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements. , 2013, Investigative ophthalmology & visual science.

[16]  Yuankai K. Tao,et al.  Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers. , 2014, Biomedical optics express.

[17]  William J Dupps,et al.  The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy (PIONEER) Study: 2-year results. , 2014, American journal of ophthalmology.

[18]  Justis P. Ehlers,et al.  The value of intraoperative optical coherence tomography imaging in vitreoretinal surgery , 2014, Current opinion in ophthalmology.

[19]  Peter K Kaiser,et al.  Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study , 2014, British Journal of Ophthalmology.

[20]  Oliver Findl,et al.  Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation , 2014, British Journal of Ophthalmology.

[21]  Andrew M. Rollins,et al.  Integrative Advances for OCT-Guided Ophthalmic Surgery and Intraoperative OCT: Microscope Integration, Surgical Instrumentation, and Heads-Up Display Surgeon Feedback , 2014, 2015 Conference on Lasers and Electro-Optics (CLEO).

[22]  Nassir Navab,et al.  Surgical tool detection and tracking in retinal microsurgery , 2015, Medical Imaging.