Hand rehabilitation device system (HRDS) for therapeutic applications

The hand rehabilitation approach for people who are affected by cerebral apoplexy has been a long-standing issue with researchers worldwide. Currently, scientific research has discovered a way to recover the motor function. Moreover, the sensory function can be recovered by neuroplasticity. Previously, the conventional hand rehabilitation approach only focused on the motor function. Therefore, there is a need to develop an effective hand rehabilitation device to recover both the motor and sensory functions. This research embarked on the configuration setup and evaluation of new hand rehabilitation devices using a mechanical stimulation system. The system has directly led to the stimulation of tactile senses, which can later be used to help patients who lack motor and sensory functions. The work was carried out in four stages comprising the development of a programming algorithm, the design and fabrication of the device and finally, an evaluation of the product and its functions. The objective to develop and fabricate a new robust tactile grasping type stimulator for a hand rehabilitation device has been achieved successfully. The preliminary evaluation on a healthy volunteer was carried out to identify the safety factor in the implementation of hardware and software before targeted patients are used.

[1]  M. Hommel,et al.  Vicarious function within the human primary motor cortex? A longitudinal fMRI stroke study. , 2005, Brain : a journal of neurology.

[2]  Taylor Cl,et al.  The anatomy and mechanics of the human hand. , 1955, Artificial limbs.

[3]  T. Murphy,et al.  Plasticity during stroke recovery: from synapse to behaviour , 2009, Nature Reviews Neuroscience.

[4]  Hiroyuki Shinoda,et al.  A method of selective stimulation to epidermal skin receptors for realistic touch feedback , 1999, Proceedings IEEE Virtual Reality (Cat. No. 99CB36316).

[5]  K. Seki,et al.  Spinal Interneurons Facilitate Coactivation of Hand Muscles during a Precision Grip Task in Monkeys , 2010, The Journal of Neuroscience.

[6]  R. Johansson,et al.  Tactile sensibility in the human hand: relative and absolute densities of four types of mechanoreceptive units in glabrous skin. , 1979, The Journal of physiology.

[7]  K. Stubblefield,et al.  Hand Rehabilitation Following Stroke: A Pilot Study of Assisted Finger Extension Training in a Virtual Environment , 2007, Topics in stroke rehabilitation.

[8]  Jamaluddin Mahmud,et al.  Efficacy and Safety Testing of a New Biologically Based Design Ankle Foot Orthosis in Healthy Volunteer , 2011 .

[9]  M. Chizari,et al.  Determining hyperelastic parameters of human skin using 2D finite element modelling and simulation , 2012, 2012 IEEE Symposium on Humanities, Science and Engineering Research.

[10]  Jamaluddin Mahmud,et al.  The Development of Finger Rehabilitation Device for Stroke Patients , 2013 .

[11]  G. Gini,et al.  An EMG-controlled exoskeleton for hand rehabilitation , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[12]  Takashi Komeda,et al.  Development of Dynamic Ankle Foot Orthosis for Therapeutic Application , 2012 .

[13]  Taylor Cl,et al.  The anatomy and mechanics of the human hand. , 1955 .

[14]  Takashi Komeda,et al.  Development of a grip aid system using air cylinders , 2009, 2009 IEEE International Conference on Robotics and Automation.

[15]  Mohd Nor Azmi Ab Patar,et al.  Force Sensor Detection and Performance Evaluation of New Active System Ankle Foot Orthosis , 2012 .