Differentiation of faults from power swings and detection of high impedance faults by distance relays

For maintaining security and reliable operation of distance relays power swing blocking is necessary to prevent maloperation during power swings and high impedance faults detection is necessary for operation of distance relays, since distance relays may treat high impedance faults as load since the fault will be out of reach of the relay. This paper proposes an algorithm for differentiation of faults from power swing and high impedance fault detection by distance relay simultaneously by a single algorithm, based on extracting current waveform components using Prony method. The merit of this method is demonstrated by simulating different high impedance faults and also during power swing conditions using the ATP version of the EMTP.

[1]  Yoshinori Ichikawa,et al.  A new method for detecting loss of synchronism using power and current measured on a line , 1999 .

[2]  Tadeusz Lobos,et al.  Analysis of power system transients using wavelets and Prony method , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[3]  Michel Meunier,et al.  Prony's method: an efficient tool for the analysis of earth fault currents in Petersen-coil-protected networks , 1995 .

[4]  Lou van der Sluis,et al.  Transients in Power Systems: van der Sluis/Transients , 2001 .

[5]  Lou van der Sluis,et al.  Transients in Power Systems , 2001 .

[6]  M.M. Morcos,et al.  On the use of Prony method to locate faults in loop systems by utilizing modal parameters of fault current , 2005, IEEE Transactions on Power Delivery.

[7]  Mladen Kezunovic,et al.  Fast Distance Relay Scheme for Detecting Symmetrical Fault During Power Swing , 2010, IEEE Transactions on Power Delivery.

[8]  T.S. Sidhu,et al.  A new filtering technique to eliminate decaying DC and harmonics for power system phasor estimation , 2006, 2006 IEEE Power India Conference.

[9]  J. Suonan,et al.  Real-time measurement of mean frequency in two-Machine system during power swings , 2004, IEEE Transactions on Power Delivery.

[10]  M. Kezunovic,et al.  Detection of Symmetrical Faults by Distance Relays During Power Swings , 2010, IEEE Transactions on Power Delivery.

[11]  K. Uemura,et al.  A New Alogorithm of an Accurate Fault Location for EHV/UHV Transmission Lines: Part I - Fourier Transformation Method , 1981, IEEE Transactions on Power Apparatus and Systems.

[12]  S.M. Brahma,et al.  Distance Relay With Out-of-Step Blocking Function Using Wavelet Transform , 2007, IEEE Transactions on Power Delivery.

[13]  J. Rezmer,et al.  Real-time determination of power system frequency , 1996, Quality Measurement: The Indispensable Bridge between Theory and Reality (No Measurements? No Science! Joint Conference - 1996: IEEE Instrumentation and Measurement Technology Conference and IMEKO Tec.

[14]  Bi Tianshu,et al.  Ground distance relaying algorithm for high resistance fault , 2010 .

[15]  S.E. Zocholl,et al.  Effect of waveform distortion on protective relays , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.