Design and Analysis of a Novel Bionic Cardiac Simulator

Cardiac simulator can solve the difficulties of cardiac surgeon training, minimally invasive devices lack of test methods and many other problems. But the current cardiac simulator cannot accurately simulate the real heart because of the incorrect blood circulation or uneven deformation and other reasons. An artificial muscle-driven biomimetic cardiac simulator is proposed in this paper. It is composed of heart chambers, bionic valves , external circulation, drive mechanism and a control system. Heart chambers is designed basically on true cardiac 3D data and can realize a correct correspondence of ventricular pressure and systole/diastole movement. The bionic valves can achieve one-way flowing. The driving parameters are designed based on the ventricular end-diastolic pressure of healthy adults. Experiments show that in the heart rate of 40-90 rpm conditions, the stroke volume (SV) first increases and then decreases with the peak appearing at the heart rate of 60 bpm with 65ml, which is meet the adult heart beat physiological parameters. 7.6% and 1% backflows are detected for the mitral and tricuspid valves under the heart rate of 60 bpm, which illustrates the valves cannot be tightly closed and need further improvements. The phantom was also scanned with CT and all components can be clearly identified from the slice images obtained. The cardiac simulator can be used for cardiac medical imaging studies, new equipment testing and the basic training of doctors and many other aspects.

[1]  Sudha Seshadri,et al.  50 year trends in atrial fibrillation prevalence, incidence, risk factors, and mortality in the Framingham Heart Study: a cohort study , 2015, The Lancet.

[2]  Terry M. Peters,et al.  Dynamic heart phantom with functional mitral and aortic valves , 2015, Medical Imaging.

[3]  Ali Alazmani,et al.  Design and Evaluation of a Buckled Strip Compliant Actuator , 2013, IEEE/ASME Transactions on Mechatronics.

[4]  C. Wan,et al.  Morphology and mechanical properties of ethylene‐vinyl acetate rubber/polyamide thermoplastic elastomers , 2013 .

[5]  Hao Liu,et al.  A novel dynamic cardiac simulator utilizing pneumatic artificial muscle , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[6]  Neelakantan Saikrishnan,et al.  A Novel Left Heart Simulator for the Multi-modality Characterization of Native Mitral Valve Geometry and Fluid Mechanics , 2013, Annals of Biomedical Engineering.

[7]  James J. Pilla,et al.  Development of a dynamic heart phantom prototype for Magnetic Resonance Imaging , 2010, Proceedings of the 2010 IEEE 36th Annual Northeast Bioengineering Conference (NEBEC).

[8]  B.M.W. Tsui,et al.  Improved Dynamic Cardiac Phantom Based on 4D NURBS and Tagged MRI , 2009, IEEE Transactions on Nuclear Science.

[9]  Armando Manduca,et al.  Evaluation of a rapid, multiphase MRE sequence in a heart‐simulating phantom , 2009, Magnetic resonance in medicine.

[10]  Ed Gullans,et al.  Design of a dynamic heart phantom for magnetic resonance imaging , 2009, 2009 IEEE 35th Annual Northeast Bioengineering Conference.

[11]  K. Matusiak,et al.  Dynamic heart phantom for the quality control of SPECT equipment. , 2008, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[12]  J. Molnár,et al.  Gated tomographic imaging in ectomography using a dynamic heart phantom , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[13]  J. Knuuti,et al.  A moving heart phantom for dual gated cardiac PET/CT studies , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[14]  T. Fukuda,et al.  In vitro patient-specific model of cerebral artery for evaluating procedures of endovascular intervention , 2005, IEEE International Symposium on Micro-NanoMechatronics and Human Science, 2005.

[15]  I.E. Magnin,et al.  A realistic anthropomorphic dynamic heart phantom , 2005, Computers in Cardiology, 2005.

[16]  Jan B. A. Habraken,et al.  A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom , 2004, European Journal of Nuclear Medicine and Molecular Imaging.

[17]  Diana Gerhardus Robot-assisted surgery: the future is here. , 2003, Journal of healthcare management / American College of Healthcare Executives.

[18]  Shirley Khan,et al.  Design of a dynamic cardiac MR phantom for the evaluation of cardiac MR systems , 2003, CARS.

[19]  A. Katz,et al.  Regulation of Cardiac Contraction and Relaxation , 2000, Circulation.

[20]  Global Young's modulus of urethane plastic cast of left ventricular myocardium calculated from roentgen angiographic silhouettes. , 1977, Journal of biomechanics.