Photoprocessible Hydrogel Microsensor for Local Environment Measurement on a Microfluidic Chip

On-chip environment measurement is an important technique for control ambient conditions of cells and monitoring cell activities. However, integration of many sensors in the chip has difficulties such as position and interconnection of sensors. We developed hydrogel microsensors made of photocrosslinkable resin impregnating with indicators for on-chip measurement. This sensor can be used for both area measurement and 3-D sensing by shaping the hydrogel by UV ray patterning. This sensor requires no interconnections since environmental information is detected as optical information such as brightness and color. The YCrCb color space was suitable than the HSV color space in terms of the linearity of the color calibration (H: hue, S: saturation, V: values (brightness). Y : brightness, Cr: color difference of red, Cb: color difference of blue). In this paper, we demonstrated measurement of pH distribution in the microchannel using a color indicator and measurement of oxygen consumption of brown fat cell (BFC) using a fluorescent oxygen indicator. On pH measurement, we used YCrCb color space because Cr and Cb represented monotone variation and robust against brightness fluctuation. The hydrogel was patterned by photolithography into the stripe shape and modified with the indicator. Color change was detected by a color charge-coupled device (CCD). On oxygen measurement, we formed the hydrogel impregnating with the fluorescent indicator into microsphere. Fluorescence change was detected by the spectrophotometer. We succeeded in measuring local pH distribution and oxygen consumption of BFC inside the microfluidic chip.

[1]  O. Wolfbeis,et al.  Optical multiple chemical sensing: status and current challenges. , 2007, The Analyst.

[2]  S. Achilefu,et al.  Design, synthesis and evaluation of near-infrared fluorescent pH indicators in a physiologically relevant range. , 2005, Chemical communications.

[3]  T. Fukuda,et al.  On chip single-cell separation and immobilization using optical tweezers and thermosensitive hydrogel. , 2005, Lab on a chip.

[4]  Fumihito Arai,et al.  Active size controlled on-chip droplet dispensing by magnetically driven microtool , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  Fumihito Arai,et al.  Biocompatible polymeric magnetically driven microtool for particle sorting , 2008 .

[6]  Barry W. Ninham,et al.  ‘Zur Lehre von der Wirkung der Salze’ (about the science of the effect of salts): Franz Hofmeister's historical papers , 2004 .

[7]  Mei Zhang,et al.  Mechanoelectrical Force Sensors Using Twisted Yarns of Carbon Nanotubes , 2011, IEEE/ASME Transactions on Mechatronics.

[8]  Kenji Yasuda,et al.  Single-cell growth and division dynamics showing epigenetic correlations. , 2005, The Analyst.

[9]  F. Arai,et al.  Powerful actuation of magnetized microtools by focused magnetic field for particle sorting in a chip , 2010, Biomedical microdevices.

[10]  Fumihito Arai,et al.  Pinpoint injection of microtools for minimally invasive micromanipulation of microbe by laser trap , 2003 .

[11]  Christian Krause,et al.  Composite Material for Simultaneous and Contactless Luminescent Sensing and Imaging of Oxygen and Carbon Dioxide , 2006 .

[12]  Mark Bradley,et al.  pH indicating resins. , 2004, Chemical communications.

[13]  Hiroshi Masuhara,et al.  Three-Dimensional pH Microprobing with an Optically-Manipulated Fluorescent Particle , 1996 .

[14]  B. Cannon,et al.  Thermogenic Responses in Brown Fat Cells Are Fully UCP1-dependent , 2000, The Journal of Biological Chemistry.

[15]  Helman Stern,et al.  Adaptive color space switching for tracking under varying illumination , 2005, Image Vis. Comput..

[16]  Hiroshi Iwasaki,et al.  Observation of microorganism colonies using a scanning-laser-beam pH-sensing microscope , 1995 .

[17]  Fumihito Arai,et al.  On-chip pH measurement using functionalized gel-microbeads positioned by optical tweezers. , 2008, Lab on a chip.

[18]  Hideaki Hisamoto,et al.  Healthcare Chip Based on Integrated Electrochemical Sensors Used for Clinical Diagnostics of Bun , 2006 .

[19]  Fumihito Arai,et al.  Immobilization of individual cells by local photo-polymerization on a chip. , 2005, The Analyst.

[20]  Gavin Sinclair,et al.  Characterisation of spatial and temporal changes in pH gradients in microfluidic channels using optically trapped fluorescent sensors. , 2006, Lab on a chip.

[21]  T. Fukuda,et al.  Functionalized hydrogel surface patterned in a chip for local pH sensing , 2008, 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems.

[22]  Kotaro Oyama,et al.  Microscopic detection of thermogenesis in a single HeLa cell. , 2007, Biophysical journal.

[23]  Hiroyuki Moriguchi,et al.  Observation of Individual Cell Using on-Chip Culture System , 2001 .

[24]  G R Bright,et al.  Fluorescence ratio imaging microscopy: temporal and spatial measurements of cytoplasmic pH , 1987, The Journal of cell biology.

[25]  K. Subramani,et al.  Micropatterning of Poly (Ethylene Glycol)-Diacrylate (PEG-DA) Hydrogel by Soft-Photolithography for Analysis of Cell-Biomaterial Interactions , 2009 .