Impact of plasma and whole-blood anticoagulant counter ion choice on drug stability and matrix effects during bioanalysis.

BACKGROUND Anticoagulants are used to prevent coagulation in blood samples. The plasma pH may change with a different counter ion and anticoagulant; thus, it is essential to determine effects on drug stability and the matrix effect during the bioanalytical method development. RESULTS Cross-validation of multiple compounds between different counter ions was performed and no impact from the counter ion nature was demonstrated. Moreover, plasma stabilities and matrix effects for both fluconazole and granisetron were investigated thoroughly in numerous counter ions/anticoagulants (K(3)ethylenediaminetetraacetic acid [K(3)EDTA], K(2)EDTA, NaEDTA, NaHeparin and LiHeparin). Sirolimus, a large cyclic molecule, was also tested in different whole-blood EDTA counter ions. Results showed percentage deviation less than 8.5% and percentage cross-validation less than 8.4%. CONCLUSION None of the compounds tested had an impact on the matrix stabilities and matrix effect.

[1]  S. P. Lin,et al.  Effects of anticoagulants in amino acid analysis: comparisons of heparin, EDTA, and sodium citrate in vacutainer tubes for plasma preparation. , 1998, Clinical chemistry.

[2]  B. Tomlinson,et al.  Plasma ascorbic acid: measurement, stability and clinical utility revisited. , 2001, Clinical biochemistry.

[3]  Vitamin C in plasma: a comparative study of the vitamin stabilized with trichloroacetic acid or metaphosphoric acid and the effects of storage at -70 degrees, -20 degrees, 4 degrees, and 25 degrees on the stabilized vitamin. , 1973, Clinica chimica acta; international journal of clinical chemistry.

[4]  F. Kuralay,et al.  Effect of anticoagulants on plasma homocysteine determination. , 2001, Clinica chimica acta; international journal of clinical chemistry.

[5]  D. Holt,et al.  Consensus Guidelines for Therapeutic Drug Monitoring of Rapamycin: Report of the Consensus Panel , 1995, Therapeutic drug monitoring.

[6]  D. Nierenberg Determination of serum and plasma concentrations of retinol using high-performance liquid chromatography. , 1984, Journal of chromatography.

[7]  E. Jacobson,et al.  Effects of blood processing techniques on sodium and potassium values: a comparison between Aldabra tortoises (Geochelone gigantea) and Burmese mountain tortoises (Manouria emys). , 2003, Veterinary clinical pathology.

[8]  J. Livesey,et al.  Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones. , 2001, Clinical biochemistry.

[9]  M. Tarbit,et al.  The disposition and metabolism of [14C]fluconazole in humans. , 1991, Drug metabolism and disposition: the biological fate of chemicals.

[10]  Vinod P. Shah,et al.  Workshop/conference report—Quantitative bioanalytical methods validation and implementation: Best practices for chromatographic and ligand binding assays , 2007 .

[11]  R. Haddock,et al.  Metabolism and disposition of 14C-granisetron in rat, dog and man after intravenous and oral dosing. , 1994, Xenobiotica; the fate of foreign compounds in biological systems.

[12]  D. Kromhout,et al.  Stability of blood (pro)vitamins during four years of storage at −20 °C: Consequences for epidemiologic research , 1995 .

[13]  Fabio Garofolo,et al.  The 2nd Calibration and Validation Group workshop on recent issues in good laboratory practice bioanalysis. , 2009, Bioanalysis.