Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system

BackgroundAlthough alert fatigue is blamed for high override rates in contemporary clinical decision support systems, the concept of alert fatigue is poorly defined. We tested hypotheses arising from two possible alert fatigue mechanisms: (A) cognitive overload associated with amount of work, complexity of work, and effort distinguishing informative from uninformative alerts, and (B) desensitization from repeated exposure to the same alert over time.MethodsRetrospective cohort study using electronic health record data (both drug alerts and clinical practice reminders) from January 2010 through June 2013 from 112 ambulatory primary care clinicians. The cognitive overload hypotheses were that alert acceptance would be lower with higher workload (number of encounters, number of patients), higher work complexity (patient comorbidity, alerts per encounter), and more alerts low in informational value (repeated alerts for the same patient in the same year). The desensitization hypothesis was that, for newly deployed alerts, acceptance rates would decline after an initial peak.ResultsOn average, one-quarter of drug alerts received by a primary care clinician, and one-third of clinical reminders, were repeats for the same patient within the same year. Alert acceptance was associated with work complexity and repeated alerts, but not with the amount of work. Likelihood of reminder acceptance dropped by 30% for each additional reminder received per encounter, and by 10% for each five percentage point increase in proportion of repeated reminders. The newly deployed reminders did not show a pattern of declining response rates over time, which would have been consistent with desensitization. Interestingly, nurse practitioners were 4 times as likely to accept drug alerts as physicians.ConclusionsClinicians became less likely to accept alerts as they received more of them, particularly more repeated alerts. There was no evidence of an effect of workload per se, or of desensitization over time for a newly deployed alert. Reducing within-patient repeats may be a promising target for reducing alert overrides and alert fatigue.

[1]  Diane L. Seger,et al.  Application of Information Technology: Improving Acceptance of Computerized Prescribing Alerts in Ambulatory Care , 2006, J. Am. Medical Informatics Assoc..

[2]  Roger B. Davis,et al.  Physicians' decisions to override computerized drug alerts in primary care. , 2003, Archives of internal medicine.

[3]  Marc Berg,et al.  Understanding handling of drug safety alerts: a simulation study , 2010, Int. J. Medical Informatics.

[4]  T H Payne,et al.  Drug interaction alert override rates in the Meaningful Use era , 2014, Applied Clinical Informatics.

[5]  A. Gorgels,et al.  Adherence to a guideline on cardiovascular prevention: a comparison between general practitioners and practice nurses. , 2011, International journal of nursing studies.

[6]  Thomas H. Payne,et al.  Evaluating clinical decision support systems: monitoring CPOE order check override rates in the Department of Veterans Affairs' Computerized Patient Record System. , 2008, Journal of the American Medical Informatics Association : JAMIA.

[7]  D. Bates,et al.  Effects of computerized physician order entry and clinical decision support systems on medication safety: a systematic review. , 2003, Archives of internal medicine.

[8]  Jorge A. Gálvez,et al.  Optimization of drug-drug interaction alert rules in a pediatric hospital's electronic health record system using a visual analytics dashboard , 2015, J. Am. Medical Informatics Assoc..

[9]  D. Blumenthal,et al.  The "meaningful use" regulation for electronic health records. , 2010, The New England journal of medicine.

[10]  J. Ben Davoren,et al.  Provider and pharmacist responses to warfarin drug-drug interaction alerts: a study of healthcare downstream of CPOE alerts , 2011, J. Am. Medical Informatics Assoc..

[11]  P. J. Huber The behavior of maximum likelihood estimates under nonstandard conditions , 1967 .

[12]  Robyn Tamblyn,et al.  Reasons for Physician Non-Adherence to Electronic Drug Alerts , 2004, MedInfo.

[13]  Jessica S. Ancker,et al.  Associations between healthcare quality and use of electronic health record functions in ambulatory care , 2015, J. Am. Medical Informatics Assoc..

[14]  Jeremy S. Stultz,et al.  Appropriateness of commercially available and partially customized medication dosing alerts among pediatric patients. , 2014, Journal of the American Medical Informatics Association : JAMIA.

[15]  Jonathan M. Teich,et al.  Drug-drug interactions that should be non-interruptive in order to reduce alert fatigue in electronic health records , 2012, J. Am. Medical Informatics Assoc..

[16]  D. Bates,et al.  Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. , 1998, JAMA.

[17]  Sarah C. Hopkins,et al.  Put into Practice , 2002, The Diabetes educator.

[18]  E. Lenz,et al.  Diabetes Care Processes and Outcomes in Patients Treated by Nurse Practitioners or Physicians , 2002, The Diabetes educator.

[19]  Thomas H. Payne,et al.  Review Paper: Medication-related Clinical Decision Support in Computerized Provider Order Entry Systems: A Review , 2007, J. Am. Medical Informatics Assoc..

[20]  Peter J. Embi,et al.  Evaluating alert fatigue over time to EHR-based clinical trial alerts: findings from a randomized controlled study , 2012, J. Am. Medical Informatics Assoc..

[21]  Roger B. Davis,et al.  Overrides of medication alerts in ambulatory care. , 2009, Archives of internal medicine.

[22]  Jonathan M. Teich,et al.  Improving allergy alerting in a computerized physician order entry system , 2000, AMIA.

[23]  Marc Berg,et al.  Overriding of drug safety alerts in computerized physician order entry. , 2006, Journal of the American Medical Informatics Association : JAMIA.

[24]  Margaret McDonald,et al.  Exploring the Utility of Automated Drug Alerts in Home Healthcare , 2006, Journal for healthcare quality : official publication of the National Association for Healthcare Quality.

[25]  Mary Cooper,et al.  Impact of a computerized alert during physician order entry on medication dosing in patients with renal impairment , 2002, AMIA.

[26]  Brian R. Jacobs,et al.  Case Report: Computerized Reminders Reduce the Use of Medications during Shortages , 2004, J. Am. Medical Informatics Assoc..

[27]  Nir Vulkan An Economist's Perspective on Probability Matching , 2000 .

[28]  et al.,et al.  How is the electronic health record being used? Use of EHR data to assess physician-level variability in technology use , 2014, J. Am. Medical Informatics Assoc..

[29]  Stephen T Lawless,et al.  Time for Alert-ology or RE-sensitization? , 2013, Pediatrics.

[30]  Natalie M. Pageler,et al.  A Clinical Case of Electronic Health Record Drug Alert Fatigue: Consequences for Patient Outcome , 2013, Pediatrics.

[31]  Christopher D. Wickens,et al.  How Do Automation False Alarms and Misses Affect Operator Compliance and Reliance? , 2006 .

[32]  Diane L. Seger,et al.  Overrides of medication-related clinical decision support alerts in outpatients , 2014, J. Am. Medical Informatics Assoc..

[33]  Debra Revere,et al.  Public health communications and alert fatigue , 2013, BMC Health Services Research.

[34]  D M Steinwachs,et al.  Development and Application of a Population-Oriented Measure of Ambulatory Care Case-Mix , 1991, Medical care.

[35]  W. Rogers Regression standard errors in clustered samples , 1994 .

[36]  Marc Berg,et al.  Viewpoint Paper: Some Unintended Consequences of Information Technology in Health Care: The Nature of Patient Care Information System-related Errors , 2003, J. Am. Medical Informatics Assoc..

[37]  Michael F. Rayo,et al.  Alarm system management: evidence-based guidance encouraging direct measurement of informativeness to improve alarm response , 2015, BMJ Quality & Safety.

[38]  Mica R. Endsley,et al.  Designing for Situation Awareness : An Approach to User-Centered Design , 2003 .

[39]  C. McDonald,et al.  A computerized reminder system to increase the use of preventive care for hospitalized patients. , 2001, The New England journal of medicine.