Power-line interference cancellation in ECG signals.

The efficiency of notchfilters and a subtraction procedure for power-line interference cancellation in electrocardiogram (ECG) signals is assessed. In contrast with the subtraction procedure, widely used digital notch filters unacceptably affect QRS complexes. The procedure eliminates interferences of variable amplitude and frequency. The frequency modulations are overcome by adaptive synchronized sampling. Initially, this is accomplished by current hardware power-line frequency measurement. Because this approach is impossible in battery-supplied and some computer-aidd devices, a software measurement of the power-line interference period is developed.

[1]  K. Egiazarian,et al.  Powerline interference suppression in high-resolution ECG , 2003, Computers in Cardiology, 2003.

[2]  Y. T. Zhang,et al.  A fast recursive-least-squares adaptive notch filter and its applications to biomedical signals , 2006, Medical & Biological Engineering & Computing.

[3]  P.S. Hamilton,et al.  A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG , 1996, IEEE Transactions on Biomedical Engineering.

[4]  I I Christov Dynamic powerline interference subtraction from biosignals , 2000, Journal of medical engineering & technology.

[5]  J G Webster,et al.  60-HZ interference in electrocardiography. , 1973, IEEE transactions on bio-medical engineering.

[6]  Nitish V. Thakor,et al.  Ground-Free ECG Recording with Two Electrodes , 1980, IEEE Transactions on Biomedical Engineering.

[7]  I. K. Daskalov,et al.  Subtraction of 50 Hz interference from the electrocardiogram , 2006, Medical and Biological Engineering and Computing.

[8]  I. I. Christov,et al.  New approach to the digital elimination of 50 Hz interference from the electrocardiogram , 1988, Medical and Biological Engineering and Computing.

[9]  P. A. Lynn Online digital filters for biological signals: some fast designs for a small computer , 1977, Medical and Biological Engineering and Computing.

[10]  I.K. Duskalov,et al.  Developments in ECG acquisition, preprocessing, parameter measurement, and recording , 1998, IEEE Engineering in Medicine and Biology Magazine.

[11]  S. Pei,et al.  Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression. , 1995, IEEE transactions on bio-medical engineering.

[12]  X. G. Yan,et al.  Dynamic Levkov-Christov subtraction of mains interference , 2006, Medical and Biological Engineering and Computing.

[13]  I. Daskalov,et al.  Dynamic Levkov-Christov subtraction of mains interference , 2006, Medical and Biological Engineering and Computing.

[14]  K. M. Kim,et al.  Simple self-tuned notch filter in a bio-potential amplifier , 2006, Medical and Biological Engineering and Computing.