Validation of an ingestible temperature data logging and telemetry system during exercise in the heat

ABSTRACT Aim: Intestinal temperature telemetry systems are promising monitoring and research tools in athletes. However, the additional equipment that must be carried to continuously record temperature data limits their use to training. The purpose of this study was to assess the validity and reliability of a new gastrointestinal temperature data logging and telemetry system (e-Celsius™) during water bath experimentation and exercise trials. Materials and Methods: Temperature readings of 23 pairs of e-Celsius (TeC) and VitalSense (TVS) ingestible capsules were compared to rectal thermistor responses (Trec) at 35, 38.5 and 42°C in a water bath. Devices were also assessed in vivo during steady-state cycling (n = 11) and intermittent running (n = 11) in hot conditions. Results: The water bath experiment showed TVS and TeC under-reported Trec (P<0.001). This underestimation of Trec also occurred during both cycling (mean bias vs TVS: 0.21°C, ICC: 0.84, 95% CI: 0.66–0.91; mean bias vs. TeC: 0.44°C, ICC: 0.68, 95% CI: 0.07–0.86, P<0.05) and running trials (mean bias vs. TVS: 0.15°C, ICC: 0.92, 95% CI: 0.83–0.96; mean bias vs. TeC: 0.25, ICC: 0.86, 95% CI: 0.61–0.94, P<0.05). However, calibrating the devices attenuated this difference during cycling and eliminated it during running. During recovery following cycling exercise, TeC and TVS were significantly lower than Trec despite calibration (P<0.01). Conclusion: These results indicate that both TeC and TVS under-report Trec during steady-state and intermittent exercise in the heat, with TeC predicting Trec with the least accuracy of the telemetry devices. It is therefore recommended to calibrate these devices at multiple temperatures prior to use.

[1]  T Reilly,et al.  Physiological responses to laboratory-based soccer-specific intermittent and continuous exercise , 2000, Journal of sports sciences.

[2]  B. Ruby,et al.  Core-temperature sensor ingestion timing and measurement variability. , 2010, Journal of athletic training.

[3]  S M Lee,et al.  Core temperature measurement during supine exercise: esophageal, rectal, and intestinal temperatures. , 2000, Aviation, space, and environmental medicine.

[4]  A. Gauthier,et al.  Performance testing of an innovative telemetric temperature sensor in animals , 2012 .

[5]  T. Reilly,et al.  A comparison of the suitabilities of rectal, gut, and insulated axilla temperatures for measurement of the circadian rhythm of core temperature in field studies , 2002, Chronobiology international.

[6]  G. Tew,et al.  Reliability of Intestinal Temperature Using an Ingestible Telemetry Pill System During Exercise in a Hot Environment , 2014, Journal of strength and conditioning research.

[7]  Craig G Crandall,et al.  Temporal thermometry fails to track body core temperature during heat stress. , 2007, Medicine and science in sports and exercise.

[8]  D. Maclaren,et al.  Carbohydrate ingestion and pre-cooling improves exercise capacity following soccer-specific intermittent exercise performed in the heat , 2011, European Journal of Applied Physiology.

[9]  Stuart M. C. Lee,et al.  Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures , 2000 .

[10]  G. Atkinson,et al.  The validity and reliability of intestinal temperature during intermittent running. , 2006, Medicine and science in sports and exercise.

[11]  A. Gauthier,et al.  Calibration and performance assessment of a temperature sensor prototype using a 1-point calibration procedure. , 2012, The Review of scientific instruments.

[12]  Chris Easton,et al.  Rectal, telemetry pill and tympanic membrane thermometry during exercise heat stress , 2007 .

[13]  W. L. Kenney,et al.  Blood pressure regulation III: what happens when one system must serve two masters: temperature and pressure regulation? , 2013, European Journal of Applied Physiology.

[14]  C. L. Lim,et al.  The ingestible telemetric body core temperature sensor: a review of validity and exercise applications , 2006, British Journal of Sports Medicine.

[15]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[16]  S. Racinais,et al.  Daily variation in body core temperature using radio-telemetry in aluminium industry shift-workers , 2012 .

[17]  W G Hopkins,et al.  Measures of Reliability in Sports Medicine and Science , 2000, Sports medicine.

[18]  Laurie A. Blanchard,et al.  Validation of a temperature telemetry system during moderate and strenuous exercise , 1993 .

[19]  M. Millard-Stafford,et al.  Monitoring core temperature during exercise: ingestible sensor vs. rectal thermistor. , 1992, Aviation, space, and environmental medicine.

[20]  A. Edwards,et al.  Thermoregulatory observations in soccer match play: professional and recreational level applications using an intestinal pill system to measure core temperature , 2006, British Journal of Sports Medicine.

[21]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[22]  L. Rowell,et al.  INDOCYANINE GREEN CLEARANCE AND ESTIMATED HEPATIC BLOOD FLOW DURING MILD TO MAXIMAL EXERCISE IN UPRIGHT MAN. , 1964, The Journal of clinical investigation.

[23]  A. de Haan,et al.  Telemetry pill versus rectal and esophageal temperature during extreme rates of exercise-induced core temperature change , 2012, Physiological measurement.

[24]  Douglas J Casa,et al.  Validity of devices that assess body temperature during outdoor exercise in the heat. , 2007, Journal of athletic training.

[25]  N. Secher,et al.  Pulmonary artery and intestinal temperatures during heat stress and cooling. , 2012, Medicine and science in sports and exercise.

[26]  J. E. McKenzie,et al.  Validation of a new telemetric core temperature monitor , 2004 .

[27]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[28]  M. Kolka,et al.  Use of an ingestible telemetry sensor to measure core temperature under chemical protective clothing , 1997 .