Double façades: comfort and ventilation aspects at an extremely complex case study

Highly glazed building envelopes are still a common feature of today's modern architecture despite the on-going raging debate on the energy and comfort performance of highly glazed buildings. It is argued by proponents of high performance and green building designs that the disadvantages of highly glazed buildings outweigh the advantages when operational. In this study, through on-site measurement and simulations, we investigated the behaviour of a recently completed naturally ventilated double-skin façade system at a building in the netherlands with a complex form and a large atrium connecting it to the core of the building. This in a way coupled with the exhaust ventilation of the offices within the building created a problematic thermal indoor environment. It was shown that the dynamic behaviour due to the large influence of the wind fluctuations and solar radiance proved to be highly complex resulting in discomfort and a higher cooling load.

[1]  A. Richards Energy and buildings , 2012 .

[2]  M. Pietrafesa,et al.  A model for managing and evaluating solar radiation for indoor thermal comfort , 2007 .

[3]  S. Tanabe,et al.  Comfort limits for asymmetric thermal radiation , 1985 .

[4]  Michele De Carli,et al.  Evaluation of various CFD modelling strategies in predicting airflow and temperature in a naturally ventilated double skin façade , 2011 .

[5]  Zhiqiang Zhai,et al.  Numerical investigation on thermal performance and correlations of double skin façade with buoyancy-driven airflow , 2008 .

[6]  Jlm Jan Hensen,et al.  Quantifying the relevance of adaptive thermal comfort models in moderate thermal climate zones , 2007 .

[7]  Ning Lin,et al.  Experimental and zonal modeling for wind pressures on double-skin facades of a tall building , 2012 .

[8]  P. Fanger Calculation of Thermal Comfort, Introduction of a Basic Comfort Equation , 1967 .

[9]  S. Corgnati,et al.  Experimental assessment of the performance of an active transparent façade during actual operating conditions , 2007 .

[10]  L Fontana Study on a mean radiant temperature measure tool based on an almost spherical array of radiometric sensors. , 2012, The Review of scientific instruments.

[11]  Per Heiselberg,et al.  Literature Review of Double Skin Facades Modelling Approaches: Report for IEA ECBCS Annex 43/SHC Task 34 Validation of Building Energy Simulation Tools , 2005 .

[12]  A. Hwang [Thermal comfort]. , 1990, Taehan kanho. The Korean nurse.

[13]  K. F. Fong,et al.  Investigation on energy performance of double skin façade in Hong Kong , 2009 .

[14]  G. Cannistraro,et al.  Algorithms for the calculation of the view factors between human body and rectangular surfaces in parallelepiped environments , 1992 .

[15]  Nathan Mendes,et al.  NUMERICAL METHOD FOR CALCULATING VIEW FACTOR BETWEEN TWO SURFACES , 2007 .

[16]  Hui Zhang,et al.  Window performance for human thermal comfort , 2006 .

[17]  Jørgen Erik Christensen,et al.  A Method for more specific Simulation of Operative Temperature in Thermal Analysis Programmes , 2008 .

[18]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[19]  F. Haghighat,et al.  Modeling ventilated double skin façade—A zonal approach , 2008 .

[20]  Guohui Gan,et al.  Analysis of mean radiant temperature and thermal comfort , 2001 .

[21]  Boris Igor Palella,et al.  On the measurement of the mean radiant temperature and its influence on the indoor thermal environment assessment , 2013 .

[22]  W. E. Stewart,et al.  Comprar Transport Phenomena, Revised 2nd Edition | Edwin N. Lightfoot | 9780470115398 | Wiley , 2007 .

[23]  Marjan Sarshar,et al.  Thermal behaviour of a ventilated double skin façade in hot arid climate , 2010 .

[24]  V. Serra,et al.  Experimental evaluation of a climate façade: Energy efficiency and thermal comfort performance , 2010 .

[25]  Fariborz Haghighat,et al.  Airflow and heat transfer in double skin facades , 2011 .

[26]  van J Joost Hoof,et al.  Forty years of Fanger’s model of thermal comfort: comfort for all? , 2008 .

[27]  André De Herde,et al.  Greenhouse effect in double-skin facade , 2007 .

[28]  Daniel R. Rousse,et al.  A comprehensive review of solar facades. Transparent and translucent solar facades , 2012 .

[29]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[30]  André De Herde,et al.  Natural cooling strategies efficiency in an office building with a double-skin facade , 2004 .

[31]  M. Glória Gomes,et al.  Gap inner pressures in multi-storey double skin facades , 2008 .

[32]  Monika Woloszyn,et al.  Three-dimensional simulation with a CFD tool of the airflow phenomena in single floor double-skin facade equipped with a venetian blind , 2005 .

[33]  Shafqat Hussain,et al.  Evaluation of various turbulence models for the prediction of the airflow and temperature distributions in atria , 2012 .

[34]  Tianzhen Hong,et al.  Building simulation: an overview of developments and information sources , 2000 .

[35]  Dirk Saelens,et al.  Strategies to improve the energy performance of multiple-skin facades , 2008 .

[36]  David Chow,et al.  Heat transfer and air movement behaviour in a double-skin façade , 2014 .

[37]  Qingyan Chen,et al.  Experimental and numerical analysis of heat transfer and airflow on an interactive building facade , 2010 .