The Impact of Roller Pump vs. Centrifugal Pump on Homologous Blood Transfusion in Pediatric Cardiac Surgery.

Centrifugal pumps are considered to be less destructive to blood elements (1) when compared to roller pumps. However, their large prime volumes render them unsuitable as arterial pumps in heart lung machine (HLM) circuitry for children. In November of 2014, the circuit at Arnold Palmer Hospital, a Biomedicus BP-50 with kinetic assist venous drainage (KAVD) and 1/4″ tubing was converted to a roller pump in the arterial position with gravity drainage. Vacuum-assisted venous drainage (VAVD) was mounted on the HLM as a backup, but not used. Tubing was changed to 3/16″ in the arterial line in patients <13 kg. A retrospective study with a total of 140 patients compared patients placed on cardiopulmonary bypass (CPB) with Biomedicus centrifugal pumps and KAVD (Centrifugal Group, n = 40) to those placed on CPB with roller pumps and gravity drainage (Roller Group, n = 100). Patients requiring extra-corporeal membrane oxygenation (ECMO)/cardio-pulmonary support (CPS) or undergoing a hybrid procedure were excluded. Re-operation or circulatory arrest patients were not excluded. Prime volumes decreased by 57% from 456 ± 34 mL in the Centrifugal Group to 197 ± 34 mL in the Roller Group (p < .001). There was a corresponding increase in hematocrit (HCT) of blood primes and also on CPB. Intraoperative homologous blood transfusions also decreased 55% from 422 mL in the Centrifugal Group to 231 mL in the Roller Group (p < .001). The Society of Thoracic Surgeons--European Association for Cardio-Thoracic Surgery (STAT) categorized intubation times and hospital length of stay (LOS) for all infants showed a trend toward reduction, but was not statistically significant. Overall mortality was 5% utilizing the centrifugal configuration and 0% in the roller pump cohort. We demonstrated that the transition to roller pumps in the arterial position of the HLM considerably reduced our priming volume and formed a basis for a comprehensive blood conservation program. By maintaining higher HCTs on CPB, we were able to reduce intraoperative homologous blood transfusions.

[1]  J. Tobias,et al.  A single‐center strategy to minimize blood transfusion in neonates and children undergoing cardiac surgery , 2015, Paediatric anaesthesia.

[2]  D. Faraoni,et al.  Predictive factors for red blood cell transfusion in children undergoing noncomplex cardiac surgery. , 2014, The Annals of thoracic surgery.

[3]  M. Galantowicz,et al.  Bloodless pediatric cardiopulmonary bypass for a 3.2-kg patient whose parents are of Jehovah's Witness faith. , 2014, The journal of extra-corporeal technology.

[4]  M. Redlin,et al.  Blood transfusion determines postoperative morbidity in pediatric cardiac surgery applying a comprehensive blood-sparing approach. , 2013, The Journal of thoracic and cardiovascular surgery.

[5]  J. Forbess,et al.  Use of del Nido cardioplegia solution and a low-prime recirculating cardioplegia circuit in pediatrics. , 2013, The journal of extra-corporeal technology.

[6]  R. Hetzer,et al.  Transfusion-free complex cardiac surgery: with use of deep hypothermic circulatory arrest in a preterm 2.96-kg Jehovah's witness neonate. , 2011, Texas Heart Institute journal.

[7]  R. Thiagarajan,et al.  Blood transfusion is associated with prolonged duration of mechanical ventilation in infants undergoing reparative cardiac surgery , 2011, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[8]  D. Holt,et al.  Are there benefits to a fresh whole blood vs. packed red blood cell cardiopulmonary bypass prime on outcomes in neonatal and pediatric cardiac surgery? , 2007, The journal of extra-corporeal technology.

[9]  R. Hetzer,et al.  Transfusion-free cardiac reoperation in an 11-kg Jehovah's Witness child by use of a minimized cardiopulmonary bypass circuit. , 2007, Texas Heart Institute journal.

[10]  R. Hetzer,et al.  Transfusion-free complex cardiac surgery with cardiopulmonary bypass in a 3.55-kg Jehovah's Witness neonate. , 2005, The Annals of thoracic surgery.

[11]  S. Brister,et al.  Coagulation disorders of cardiopulmonary bypass: a review , 2004, Intensive Care Medicine.

[12]  Frank Merkle,et al.  Perfusion technique for nonhaemic cardiopulmonary bypass prime in neonates and infants under 6 kg body weight , 2004, Perfusion.

[13]  Masahiro Yoshida,et al.  Efficacy of a criterion-driven transfusion protocol in patients having pediatric cardiac surgery. , 2004, The Journal of thoracic and cardiovascular surgery.

[14]  J. Jacobs,et al.  Assisted venous drainage cardiopulmonary bypass in congenital heart surgery. , 2001, The Annals of thoracic surgery.

[15]  K. Sanger,et al.  Superiority of centrifugal pump over roller pump in paediatric cardiac surgery: prospective randomised trial. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[16]  J. Mathew,et al.  Cardiopulmonary bypass induces leukocyte-platelet adhesion. , 1992, Blood.