Spatial resolution improvement for point light source detection in scintillator cube using SPAD array with multi pinholes
暂无分享,去创建一个
[1] Chris A. Glasbey,et al. Machine Vision and Applications Manuscript No. Non-destructive Automatic Leaf Area Measurements by Combining Stereo and Time-of-flight Images , 2022 .
[2] F. Loddo,et al. Time and DOI resolution measurements of minidetectors for a PET-TOF prostate probe , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.
[3] H. Murayama,et al. Development of the X'tal Cube: A 3D Position-Sensitive Radiation Detector With All-Surface MPPC Readout , 2012, IEEE Transactions on Nuclear Science.
[4] T. Takahashi,et al. High Energy Resolution Hard X-Ray and Gamma-Ray Imagers Using CdTe Diode Devices , 2009, IEEE Transactions on Nuclear Science.
[5] Yasushi Fukazawa,et al. Study of event reconstruction algorithm for a large-scale Si/CdTe multilayer Compton camera , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).
[6] Kai Xu,et al. High Spatial Resolution Detection Method for Point Light Source in Scintillator , 2017, Computational Imaging.
[7] Hideaki Tashima,et al. The X'tal cube PET detector of isotropic (0.8 mm)3 crystal segments , 2014, 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
[8] Motohide Kokubun,et al. Estimation of energy range measurements with newly developed Si/CdTe Compton camera for nuclear medicine imaging , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.
[9] Kamel Hamrouni,et al. Noise modelling in time-of-flight sensors with application to depth noise removal and uncertainty estimation in three-dimensional measurement , 2015, IET Comput. Vis..
[10] Toru Nakura,et al. A 15 × 15 single photon avalanche diode sensor featuring breakdown pixels extraction architecture for efficient data readout , 2016 .
[11] Ezzeddine Zagrouba,et al. Non-subsampled shearlet transform based MRI and PET brain image fusion using simplified pulse coupled neural network and weight local features in YIQ colour space , 2018, IET Image Process..
[12] T. Takahashi,et al. A Si/CdTe semiconductor Compton camera , 2004, IEEE Transactions on Nuclear Science.
[13] Y. Nakamura,et al. Design and fabrication of endoscope-type Compton camera and its real time imaging system , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).
[14] Ricardo Carmona-Galán,et al. A CMOS Digital SiPM With Focal-Plane Light-Spot Statistics for DOI Computation , 2017, IEEE Sensors Journal.
[15] Hideaki Tashima,et al. Impact of Laser-Processed X'tal Cube Detectors on PET Imaging in a One-Pair Prototype System , 2013, IEEE Transactions on Nuclear Science.
[16] G. Anton,et al. 3D-position-sensitive compact scintillation detector as absorber for a Compton-camera , 2005, IEEE Transactions on Nuclear Science.
[17] S. Charlebois,et al. Modeling of single photon avalanche diode array detectors for PET applications , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.
[18] Gábor Kalinka,et al. Theoretical study of three-dimensionally position-sensitive scintillation detector based on continuous crystal , 2009 .
[19] Shin Watanabe,et al. Spatial resolution of multi-head Si/CdTe Compton camera for medical application , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).
[20] Shin Watanabe,et al. Visualization of radioactive substances with a Si/CdTe Compton Camera , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).
[21] Akiyoshi Baba,et al. Modulation transfer function analysis of silicon X-ray sensor with trench-structured photodiodes , 2018, IEICE Electron. Express.
[22] K. Doroud,et al. A new approach for improved time and position measurements for TOF-PET: Time-stamping of the photo-electrons using analogue SiPMs , 2017 .
[23] Hideaki Tashima,et al. Development of the X’tal Cube PET Detector With Segments of (0.77 mm)3 , 2018, IEEE Transactions on Radiation and Plasma Medical Sciences.
[24] Taiga Yamaya,et al. Development of a DOI PET Detector Having the Structure of the X’tal Cube Extended in One Direction , 2016, IEEE Transactions on Nuclear Science.
[25] Hideaki Tashima,et al. From (0.8 mm)3 to (0.77 mm)3: Improved X'tal cube PET detector for better crystal identification , 2015, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
[26] Toru Nakura,et al. A SPAD array sensor based on breakdown pixel extraction architecture with background readout for scintillation detector , 2017, 2017 IEEE SENSORS.
[27] R. K. Henderson,et al. A Single-Photon Avalanche Diode in 90-nm CMOS Imaging Technology With 44% Photon Detection Efficiency at 690 nm , 2012, IEEE Electron Device Letters.
[28] Motohide Kokubun,et al. An evaluation of three-dimensional imaging by use of Si/CdTe Compton cameras , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).
[29] Albert J. P. Theuwissen,et al. Single-photon imaging , 2011 .
[30] T. Takahashi,et al. Demonstration of in-vivo Multi-Probe Tracker Based on a Si/CdTe Semiconductor Compton Camera , 2012, IEEE Transactions on Nuclear Science.