Differences in visual quality with orientation of a rotationally asymmetric bifocal intraocular lens design

Purpose To evaluate visual and perceptual performance for different orientations of a rotationally asymmetric bifocal intraocular lens (IOL) (M‐Plus) simulated optically using a simultaneous vision simulator. Setting Instituto de Optica, Madrid, Spain. Design Prospective observational study. Methods Perceptual quality and decimal high‐contrast visual acuity (HCVA) was measured under cycloplegia for 8 orientations of the asymmetric bifocal IOL phase pattern at far, intermediate, and near distances simulated with a simultaneous vision simulator using face images and tumbling E targets. The preferred orientation at each distance was calculated as the centroid of the data for 8 orientations. The visual Strehl value was calculated using the subjects’ ocular aberrations and multifocal pattern at each orientation. Optical predictions were obtained by implementing a differential visual Strehl values–based ideal observer model. Results The study comprised 20 subjects (aged 21 to 62 years). Horizontal orientation (near segment at 0 or 180 degrees ± 45 [SD]) was preferred by 14 subjects and by 13 subjects at far and near distances, respectively; 8 subjects showed strong orientation preferences. The mean difference in preferred orientation between far and near was 27 ± 22 degrees. No significant differences in HCVA were observed. Optical predictions correlated strongly and significantly with measurements (far r = 0.71, near r = 0.62; P < .0001). The mean difference between measurement and simulation in the preferred orientation was 28 ± 29 degrees at far and 36 ± 28 degrees at near. Conclusions The perception varied for different orientations of an asymmetric bifocal IOL design tested using a simultaneous vision simulator. Optimum orientation was driven by interactions of the design with the eye’s optical aberrations. Financial Disclosure None of the authors has a financial or proprietary interest in any material or method mentioned.

[1]  D. Fitzpatrick,et al.  Orientation Selectivity and the Arrangement of Horizontal Connections in Tree Shrew Striate Cortex , 1997, The Journal of Neuroscience.

[2]  N. López-Gil,et al.  Influence on Visual Quality of Intraoperative Orientation of Asymmetric Intraocular Lenses. , 2015, Journal of refractive surgery.

[3]  C. Bala,et al.  Improvement in vision with inverted placement of an asymmetric refractive multifocal intraocular lens. , 2014, Journal of cataract and refractive surgery.

[4]  Susana Marcos,et al.  Multiple zone multifocal phase designs. , 2013, Optics letters.

[5]  Timothy D. Wilkinson,et al.  Simulations of Time Multiplexed Fraunhofer Holograms Produced by Binary Phase SLMs for Video Projection , 2012 .

[6]  K. Fujii,et al.  Visualization for the analysis of fluid motion , 2005, J. Vis..

[7]  J. Alió,et al.  Visual outcomes with a single‐optic accommodating intraocular lens and a low‐addition‐power rotational asymmetric multifocal intraocular lens , 2012, Journal of cataract and refractive surgery.

[8]  Joseph J K Ma,et al.  Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation. , 2008, Journal of cataract and refractive surgery.

[9]  D. R. Iskander,et al.  Computational Aspects of the Visual Strehl Ratio , 2006, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  Michael Belkin,et al.  Learning to adapt: Dynamics of readaptation to geometrical distortions , 2010, Vision Research.

[11]  Susana Marcos,et al.  Combining coma with astigmatism can improve retinal image over astigmatism alone , 2010, Vision Research.

[12]  W Neil Charman,et al.  Developments in the correction of presbyopia II: surgical approaches , 2014, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[13]  S. Marcos,et al.  Short-Term Neural Adaptation to Simultaneous Bifocal Images , 2014, PloS one.

[14]  David P Piñero,et al.  Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs. , 2012, Journal of refractive surgery.

[15]  Susana Marcos,et al.  Adapting to blur produced by ocular high-order aberrations. , 2011, Journal of vision.

[16]  Susana Marcos,et al.  Experimental simulation of simultaneous vision. , 2013, Investigative ophthalmology & visual science.

[17]  J. Venter,et al.  Initial experience with a new refractive rotationally asymmetric multifocal intraocular lens. , 2014, Journal of refractive surgery.

[18]  David P Piñero,et al.  Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens. , 2012, Ophthalmology.

[19]  R. Legras,et al.  Effect of monochromatic induced aberrations on visual performance measured by adaptive optics technology. , 2010, Journal of refractive surgery.

[20]  D H Brainard,et al.  The Psychophysics Toolbox. , 1997, Spatial vision.

[21]  Arne Ohlendorf,et al.  Neuronal adaptation to simulated and optically-induced astigmatic defocus , 2011, Vision Research.

[22]  Masahiro Takei,et al.  Human resource development and visualization , 2009, J. Vis..

[23]  J. Wolffsohn,et al.  Surgical correction of astigmatism during cataract surgery , 2010, Clinical & experimental optometry.

[24]  Susana Marcos,et al.  Visual testing of segmented bifocal corrections with a compact simultaneous vision simulator , 2014 .

[25]  D. Whitaker,et al.  Factors affecting light-adapted pupil size in normal human subjects. , 1994, Investigative ophthalmology & visual science.

[26]  W. Ehrenstein,et al.  Psychophysical Methods , 1999 .

[27]  Pablo Artal,et al.  Adaptive optics simulation of intraocular lenses with modified spherical aberration. , 2004, Investigative ophthalmology & visual science.

[28]  Susana Marcos,et al.  On the symmetry between eyes of wavefront aberration and cone directionality , 2000, Vision Research.

[29]  Susana Marcos,et al.  Astigmatism Impact on Visual Performance: Meridional and Adaptational Effects , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[30]  R. Juday Correlation with a spatial light modulator having phase and amplitude cross coupling. , 1989, Applied optics.

[31]  M. Webster,et al.  Dependence of subjective image focus on the magnitude and pattern of high order aberrations. , 2012, Journal of vision.

[32]  Susana Marcos,et al.  Influence of adaptive-optics ocular aberration correction on visual acuity at different luminances and contrast polarities. , 2008, Journal of vision.

[33]  Susana Marcos,et al.  Testing vision with angular and radial multifocal designs using Adaptive Optics , 2017, Vision Research.

[34]  C Blakemore,et al.  On the existence of neurones in the human visual system selectively sensitive to the orientation and size of retinal images , 1969, The Journal of physiology.

[35]  Béatrice Cochener,et al.  Clinical Ophthalmology Dovepress Comparison of Outcomes with Multifocal Intraocular Lenses: a Meta-analysis , 2022 .

[36]  Jonathan E. Moore,et al.  Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision , 2015, Journal of cataract and refractive surgery.

[37]  George C. Woo,et al.  PRIMARY CARE OPTOMETRY , 1991 .