Patient safety incidents associated with airway devices in critical care: a review of reports to the UK National Patient Safety Agency

We used key words and letter sequences to identify airway‐associated patient safety incidents submitted to the UK National Patient Safety Agency from critical care units in England and Wales. We identified 1085 such airway incidents submitted in the two years from October 2005 to September 2007. Three hundred and twelve incidents (28.8%) involved neonates or babies. Of the total 1085 incidents, 200 (18.4%) were associated with tracheal intubation, 53 (4.9%) with tracheostomy and 893 (82.3%) were post‐procedure problems. One hundred and ten incidents (10.1%) were associated with more than temporary harm. Eighty‐eight intubation incidents were associated with equipment problems. Partial displacement of tubes resulted in more than temporary harm to the patient more frequently than complete tube displacement (15.7% vs 3.8%). Capnography was not described in any cases of displacement or blockage of tracheal or tracheostomy tubes. Recommendations concerning minimum standards for capnography, availability and checking of equipment and tracheostomy placement are made.

[1]  Melissa J. Krauss,et al.  Patient safety event reporting in critical care: A study of three intensive care units* , 2007, Critical care medicine.

[2]  S. Mackenzie,et al.  Critical incidents in the intensive therapy unit , 1991, The Lancet.

[3]  P. Kiekkas,et al.  Use of technological equipment in critical care units: nurses' perceptions in Greece. , 2006, Journal of clinical nursing.

[4]  P. Pronovost,et al.  Mechanical ventilation in Ontario, 1992–2000: Incidence, survival, and hospital bed utilization of noncardiac surgery adult patients* , 2004, Critical care medicine.

[5]  G. Bernard,et al.  Efficacy and safety of a paired sedation and ventilator weaning protocol for mechanically ventilated patients in intensive care (Awakening and Breathing Controlled trial): a randomised controlled trial , 2008, The Lancet.

[6]  S. Ito,et al.  Development of a Clipped Single-Bag with Bicarbonate Replacement Fluid to Ensure Proper Mixing , 2006, ASAIO journal.

[7]  S. Bratton,et al.  Continuous Quality Improvement: Reducing Unplanned Extubations in a Pediatric Intensive Care Unit , 2004, Pediatrics.

[8]  J. Kress,et al.  Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. , 2000, The New England journal of medicine.

[9]  W. M. Anderson,et al.  Significant tracheal obstruction causing failure to wean in patients requiring prolonged mechanical ventilation: a forgotten complication of long-term mechanical ventilation. , 1999, Chest.

[10]  S. Luria,et al.  Proposed technique for evaluation of endotracheal tube fixation and comparison of four fixation methods. , 2001, Military medicine.

[11]  T. Jones,et al.  Role of routine chest radiography after percutaneous dilatational tracheostomy. , 2008, British journal of anaesthesia.

[12]  A. Thomas,et al.  Critical incident reporting in UK intensive care units: a postal survey. , 2003, Journal of Evaluation In Clinical Practice.

[13]  E A McConnell,et al.  Australian registered nurse medical device education: a comparison of simple vs. complex devices. , 1996, Journal of advanced nursing.

[14]  C. Carvalho,et al.  Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome. , 1998, The New England journal of medicine.

[15]  D. Westenskow,et al.  Model-based detection of partially obstructed endotracheal tube* , 2005, Critical care medicine.

[16]  F. Kapadia,et al.  Changing patterns of airway accidents in intubated ICU patients , 2001, Intensive Care Medicine.

[17]  A. Ho,et al.  What to do when an endotracheal tube cuff leaks. , 1996, The Journal of trauma.

[18]  E. N. Kapadia Factors associated with blocked tracheal tubes , 2001, Intensive Care Medicine.

[19]  N. Maxvold,et al.  Medication errors and patient complications with continuous renal replacement therapy , 2006, Pediatric Nephrology.

[20]  R. K. Webb,et al.  The Australian Incident Monitoring Study. Crisis management--validation of an algorithm by analysis of 2000 incident reports. , 1993, Anaesthesia and intensive care.

[21]  A. Thomas,et al.  Patient safety incidents associated with equipment in critical care: a review of reports to the UK National Patient Safety Agency , 2008, Anaesthesia.

[22]  E. Frezza,et al.  A Quality Improvement and Risk Management Initiative for Surgical ICU Patients: A Study of the Effects of Physical Restraints and Sedation on the Incidence of Self-extubation , 2000, American journal of medical quality : the official journal of the American College of Medical Quality.

[23]  J. R. Roberts,et al.  An analysis of training activities in the use of critical care equipment within hospitals in the United Kingdom , 1998, Anaesthesia.

[24]  R Shaw,et al.  Adverse events and near miss reporting in the NHS , 2005, Quality and Safety in Health Care.

[25]  Vimla L. Patel,et al.  Heuristic evaluation of infusion pumps: implications for patient safety in Intensive Care Units , 2004, Int. J. Medical Informatics.

[26]  Albert W. Wu,et al.  Incidents relating to the intra-hospital transfer of critically ill patients , 2004, Intensive Care Medicine.

[27]  W J Russell,et al.  Equipment Failure: An Analysis of 2000 Incident Reports , 1993 .

[28]  P. Metnitz,et al.  Patient safety in intensive care: results from the multinational Sentinel Events Evaluation (SEE) study , 2006, Intensive Care Medicine.

[29]  A. N. Thomas,et al.  Medication‐related patient safety incidents in critical care: a review of reports to the UK National Patient Safety Agency * , 2008, Anaesthesia.

[30]  J. Mitchell Recommendations for standards of monitoring during anaesthesia and recovery , 2001, Anaesthesia.

[31]  J. Timsit,et al.  Impact of Unplanned Extubation and Reintubation after Weaning on Nosocomial Pneumonia Risk in the Intensive Care Unit: A Prospective Multicenter Study , 2002, Anesthesiology.

[32]  Brian H Cuthbertson,et al.  Can physiological variables and early warning scoring systems allow early recognition of the deteriorating surgical patient?* , 2007, Critical care medicine.

[33]  F. Kapadia Effect of unplanned extubation on outcome of mechanical ventilation. , 2001, American journal of respiratory and critical care medicine.

[34]  Stacy R Schultz,et al.  Patient safety event reporting in a large radiology department. , 2011, AJR. American journal of roentgenology.

[35]  Jared Cash,et al.  Standard Drug Concentrations and Smart-Pump Technology Reduce Continuous-Medication-Infusion Errors in Pediatric Patients , 2005, Pediatrics.

[36]  L Beydon,et al.  Analysis of the French health ministry's national register of incidents involving medical devices in anaesthesia and intensive care. , 2001, British journal of anaesthesia.

[37]  N. Stanhope,et al.  Reasons for not reporting adverse incidents: an empirical study. , 1999, Journal of evaluation in clinical practice.

[38]  Monica O’Kelly,et al.  Evaluation in clinical practice , 2004 .

[39]  C. Holzmueller,et al.  A system factors analysis of airway events from the Intensive Care Unit Safety Reporting System (ICUSRS)* , 2004, Critical care medicine.

[40]  M. Nirmalan,et al.  Editorial IV: physical and pharmacological restraint of critically ill patients: clinical facts and ethical considerations. , 2004, British journal of anaesthesia.