Calculated moment-arm and muscle-tendon lengths during gait differ substantially using MR based versus rescaled generic lower-limb musculoskeletal models.

Biomechanical analysis of gait relies on the use of lower-limb musculoskeletal models. Most models are based on a generic model which takes into account the subject's skeletal dimensions by isotropic or anisotropic rescaling. Alternatively, personalized models can be built based on information from magnetic resonance (MR) images. We have studied the effect of these approaches on muscle-tendon lengths (MTLs) and moment-arm lengths (MALs) for 16 major muscles of the lower limb of a normal adult during both normal and pathologic gait. For most muscles, the MTL and MAL calculated using the rescaled generic models showed high correlation values, but large offsets when compared to values calculated using personalized models. MTL and MAL differences with the personalized model are only slightly smaller for an anisotropic than for an isotropic rescaled model. Gait kinematics influenced the observed inter-model differences and correlations due to an altered range of joint angles in both gait patterns. In conclusion, both generic rescaling methods failed to accurately estimate absolute values for MTL and MAL calculated using the personalized model. However, the magnitude of MTL and MAL changes during normal and pathologic gait corresponded between all three models for most muscles. Since rescaling depends strongly on modelling assumptions and cannot fully take into account subject-specific musculoskeletal geometry, interpretation of MTL and MAL even in normal adult subjects requires extreme caution.

[1]  J. Mazziotta,et al.  Cross-sectional anatomy: An atlas for computerized tomography , 1977 .

[2]  E. Leonard,et al.  Controlled Cell Deformation Produces Defined Areas of Contact between Cells and Ligand-Coated Surfaces , 2004, Annals of Biomedical Engineering.

[3]  G L Soderberg,et al.  Electromyographic study of three parts of the gluteus medius muscle during functional activities. , 1978, Physical therapy.

[4]  J. Basmajian Muscles Alive—their functions revealed by electromyography , 1963 .

[5]  R. K. Beals,et al.  Developmental Changes in the Femur and Acetabulum in Spastic Paraplegia and Diplegia , 1969, Developmental medicine and child neurology.

[6]  James A. Sethian,et al.  Level Set Methods and Fast Marching Methods , 1999 .

[7]  E. Schneider,et al.  Variability of femoral muscle attachments. , 1996, Journal of biomechanics.

[8]  S. Delp,et al.  Accuracy of muscle moment arms estimated from MRI-based musculoskeletal models of the lower extremity. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[9]  S. Delp,et al.  Evaluation of a Deformable Musculoskeletal Model for Estimating Muscle–Tendon Lengths During Crouch Gait , 2001, Annals of Biomedical Engineering.

[10]  F.E. Zajac,et al.  An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures , 1990, IEEE Transactions on Biomedical Engineering.

[11]  S. Delp,et al.  Computer modeling of gait abnormalities in cerebral palsy: application to treatment planning , 2005 .

[12]  E. Kaplan Muscles Alive. Their Functions Revealed by Electromyography. J. V. Basmajian. Baltimore, The Williams and Wilkins Co., 1962. $8.50 , 1962 .

[13]  Sheldon R Simon,et al.  Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. , 2004, Journal of biomechanics.

[14]  A. Thorstensson,et al.  Intramuscular EMG from the hip flexor muscles during human locomotion. , 1997, Acta physiologica Scandinavica.

[15]  Paul Suetens,et al.  Image Based Musculoskeletal Modeling Allows Personalized Biomechanical Analysis of Gait , 2006, ISBMS.

[16]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[17]  R. Evens,et al.  An Atlas of Cross-Sectional Anatomy , 1980 .

[18]  May Q. Liu,et al.  Do the hamstrings operate at increased muscle-tendon lengths and velocities after surgical lengthening? , 2006, Journal of biomechanics.

[19]  M. Rooze,et al.  Theoretical Study of the Decrease in the Femoral Neck Anteversion during Growth , 2002, Cells Tissues Organs.

[20]  J. Perry,et al.  Gait Analysis , 2024 .

[21]  R. Gregor,et al.  In vivo moment arm calculations at the ankle using magnetic resonance imaging (MRI). , 1990, Journal of biomechanics.

[22]  R. Keagy,et al.  Direct electromyography of the psoas major muscle in man. , 1966, The Journal of bone and joint surgery. American volume.

[23]  Roger C. Crafts,et al.  Textbook of Human Anatomy , 1957 .

[24]  C. A. Byrne,et al.  Is rectus femoris really a part of quadriceps? Assessment of rectus femoris function during gait in able-bodied adults. , 2004, Gait & posture.

[25]  F. Zajac,et al.  A planar model of the knee joint to characterize the knee extensor mechanism. , 1989, Journal of biomechanics.