Single-phase dynamically decoupled active power filter for system-integrated application

A novel topology for active power filters (APF) has been proposed. This filter can be used in combination with passive parallel filters effectively to reduce the power rating of the active filter. Hence, if no power-factor compensation at fundamental frequency is required, then during steady state only a small fraction of harmonic current flows through this filter which effectively reduces the size and power dissipation of the filter. A major issue in control of parallel and series active power filters is their tendency to oscillate in the presence of certain kinds of reactive load. This problem becomes even worse when control loops with one-cycle control delay using digital signal processors are implemented. The proposed topology is relatively immune from such load–source-impedance-interaction. This filter can provide a cost-effective solution for system-integrated design where the filter is supposed to be the part of the application. The proposed system has been studied analytically and tested using computer simulations and experiments.

[1]  Juan Dixon,et al.  A fault protection scheme for series active power filters , 1996 .

[2]  Kamal Al-Haddad,et al.  A new control approach to three-phase active filter for harmonics and reactive power compensation , 1998 .

[3]  Hirofumi Akagi Trends in active power line conditioners , 1994 .

[4]  Luis Morán,et al.  Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads , 1995, IEEE Trans. Ind. Electron..

[5]  P. Mehta,et al.  Active power filters: a review , 2000 .

[6]  Ned Mohan,et al.  Hybrid-active filtering of harmonic currents in power systems , 1995 .

[7]  H.-L. Jou,et al.  Simplified control method for the single-phase active power filter , 1996 .

[8]  Shyh-Jier Huang,et al.  Design and operation of cascaded active power filters for the reduction of harmonic distortions in a power system , 1999 .

[9]  S. J. Chiang,et al.  Parallel operation of capacity-limited three-phase four-wire active power filters , 2002 .

[10]  Hirofumi Akagi Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribution Systems , 1997 .

[11]  H. Akagi,et al.  A practical approach to harmonic compensation in power systems-series connection of passive and active filters , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[12]  Po-Tai Cheng,et al.  Hybrid solutions for improving passive filter performance in high power applications , 1997 .