Research approaches for studying flow-induced thromboembolic complications in blood recirculating devices

The advent of implantable blood recirculating devices has provided life-saving solutions to patients with severe cardiovascular diseases. Recently it has been reported that ventricular assist devices are superior to drug therapy. The implantable total artificial heart is showing promise as a potential solution to the chronic shortage of available heart transplants. Prosthetic heart valves are routinely used for replacing diseased heart valves. However, all of these devices share a common problem – significant complications such as hemolysis and thromboembolism often arise after their implantation. Elevated flow stresses that are present in the nonphysiologic geometries of blood recirculating devices, enhance their propensity to initiate thromboembolism by chronically activating the blood platelets. This, rather than hemolysis, appears to be the salient aspect of blood trauma in devices. Limitations in characterizing and controlling relevant aspects of the flow-induced mechanical stimuli and the platelet response, hampers our ability to achieve design optimization for these devices. The main objective of this article is to describe state-of-the-art numerical, experimental, and in vivo tools, that facilitate elucidation of flow-induced mechanisms leading to thromboembolism in prosthetic devices. Such techniques are giving rise to an accountable model for flow-induced thrombogenicity, and to a methodology that has the potential to transform current device design and testing practices. It might lead to substantial time and cost savings during the research and development phase, and has the potential to reduce the risks that patients implanted with these devices face, lower the ensuing healthcare costs, and offer viable long-term solutions for these patients.

[1]  H Reul,et al.  In Vitro Thrombogenicity Testing of Artificial Organs , 1998, The International journal of artificial organs.

[2]  H Reul,et al.  Computational Fluid Dynamics and Experimental Validation of a Microaxial Blood Pump , 2001, ASAIO journal.

[3]  Gross Jm,et al.  Vortex shedding in bileaflet heart valve prostheses. , 1988 .

[4]  H. Markus,et al.  Detection of circulating cerebral emboli using Doppler ultrasound in a sheep model , 1994, Journal of the Neurological Sciences.

[5]  Hwa Liang Leo,et al.  Bileaflet Aortic Valve Prosthesis Pivot Geometry Influences Platelet Secretion and Anionic Phospholipid Exposure , 2001, Annals of Biomedical Engineering.

[6]  C Bludszuweit,et al.  Model for a general mechanical blood damage prediction. , 1995, Artificial organs.

[7]  B. Reichart,et al.  Experience with the Novacor left ventricular assist system as a bridge to cardiac transplantation, including the new wearable system. , 1995, The Journal of thoracic and cardiovascular surgery.

[8]  M. Gharib,et al.  Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. , 2000, Journal of biomechanical engineering.

[9]  Stanley E. Rittgers,et al.  Particle Motion Within In Vitro Models of Stenosed Internal Carotid and Left Anterior Descending Coronary Arteries , 1998, Annals of Biomedical Engineering.

[10]  James F. Antaki,et al.  Computational Simulation of Platelet Deposition and Activation: I. Model Development and Properties , 1999, Annals of Biomedical Engineering.

[11]  B. Griffith,et al.  A design improvement strategy for axial blood pumps using computational fluid dynamics. , 1996, ASAIO journal (1992).

[12]  K. Lees,et al.  Differentiation Between Gaseous and Formed Embolic Materials In Vivo: Application in Prosthetic Heart Valve Patients , 1994, Stroke.

[13]  L V McIntire,et al.  Mathematical analysis of mural thrombogenesis. Concentration profiles of platelet-activating agents and effects of viscous shear flow. , 1989, Biophysical journal.

[14]  S P Sutera,et al.  Deformation and fragmentation of human red blood cells in turbulent shear flow. , 1975, Biophysical journal.

[15]  W Jin,et al.  Experimental investigation of unsteady flow behaviour within a sac-type ventricular assist device (VAD). , 1993, Journal of biomechanics.

[16]  J R O'Brien,et al.  An independent haemostatic mechanism: shear induced platelet aggregation. , 1990, Advances in experimental medicine and biology.

[17]  Danny Bluestein,et al.  Vortex Shedding in Steady Flow Through a Model of an Arterial Stenosis and Its Relevance to Mural Platelet Deposition , 1999, Annals of Biomedical Engineering.

[18]  S H Chu,et al.  Turbulence characteristics downstream of bileaflet aortic valve prostheses. , 2000, Journal of biomechanical engineering.

[19]  R L Kormos,et al.  Assessment of biventricular cardiac function in patients with a Novacor left ventricular assist device. , 1994, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[20]  J F Antaki,et al.  A mathematical model for shear-induced hemolysis. , 1995, Artificial organs.

[21]  S. Jones A relationship between reynolds stresses and viscous dissipation: Implications to red cell damage , 2006, Annals of Biomedical Engineering.

[22]  S Einav,et al.  The effect of varying degrees of stenosis on the characteristics of turbulent pulsatile flow through heart valves. , 1995, Journal of biomechanics.

[23]  C Bludszuweit,et al.  Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. , 1995, Artificial organs.

[24]  V. Jeevanandam,et al.  The effects of Carmeda Bioactive Surface on human blood components during simulated extracorporeal circulation. , 1996, The Journal of thoracic and cardiovascular surgery.

[25]  Todd D. Giorgio,et al.  Studies on the Mechanisms of Shear-Induced Platelet Activation , 1987 .

[26]  Shmuel Einav,et al.  Techniques in the Stability Analysis of Pulsatile Flow Through Heart Valves , 2000 .

[27]  C S Peskin,et al.  Computer-assisted design of pivoting disc prosthetic mitral valves. , 1983, The Journal of thoracic and cardiovascular surgery.

[28]  G. Grunkemeier,et al.  Low risk of thrombosis and serious embolic events despite low-intensity anticoagulation. Experience with 1,004 Medtronic Hall valves. , 1988, Circulation.

[29]  E. Bodnar The Medtronic Parallel valve and the lessons learned. , 1996, The Journal of heart valve disease.

[30]  H N Sabbah,et al.  Turbulent stresses in the region of aortic and pulmonary valves. , 1982, Journal of biomechanical engineering.

[31]  E. Ringelstein,et al.  Oxygen inhalation can differentiate gaseous from nongaseous microemboli detected by transcranial Doppler ultrasound. , 1997, Stroke.

[32]  A. Ebert,et al.  Neurobehavioral outcome prediction after cardiac surgery: role of neurobiochemical markers of damage to neuronal and glial brain tissue. , 2000, Stroke.

[33]  L. Hiratzka,et al.  Effect of valve orientation on flow development past aortic valve prostheses in a model human aorta. , 1983, The Journal of thoracic and cardiovascular surgery.

[34]  T. Giorgio,et al.  The effects of elongational stress exposure on the activation and aggregation of blood platelets. , 1991, Biorheology.

[35]  T. Ino,et al.  Platelet activation in the gyro C1E3 centrifugal pump: comparison with the terumo capiox and the Nikkiso HPM-15. , 2000, Artificial organs.

[36]  G. Grunkemeier,et al.  Twenty years' experience with the Medtronic Hall valve. , 2001, The Journal of thoracic and cardiovascular surgery.

[37]  D. Wilcox Simulation of Transition with a Two-Equation Turbulence Model , 1994 .

[38]  I. Krukenkamp,et al.  Free emboli formation in the wake of bi-leaflet mechanical heart valves and the effects of implantation techniques. , 2002, Journal of biomechanics.

[39]  P. Perrotta,et al.  Platelet activation in a circulating flow loop: combined effects of shear stress and exposure time , 2003, Platelets.

[40]  Wei Yin,et al.  Flow induced platelet activation in mechanical heart valves - in vitro studies , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[41]  H. Sabbah,et al.  Fluid dynamic stresses in the region of a porcine bioprosthetic valve. , 1982, Henry Ford Hospital medical journal.

[42]  G Rosenberg,et al.  Relative blood damage in the three phases of a prosthetic heart valve flow cycle. , 1993, ASAIO journal.

[43]  M Cerrolaza,et al.  Analysis of 3D transient blood flow passing through an artificial aortic valve by Lattice-Boltzmann methods. , 1998, Journal of biomechanics.

[44]  Umberto Morbiducci,et al.  The power-law mathematical model for blood damage prediction: analytical developments and physical inconsistencies. , 2004, Artificial organs.

[45]  C S Peskin,et al.  Cardiac fluid dynamics. , 1992, Critical reviews in biomedical engineering.

[46]  O H Frazier,et al.  The AbioCor implantable replacement heart. , 2003, The Annals of thoracic surgery.

[47]  J. O'brien,et al.  Shear-induced platelet aggregation , 1990, The Lancet.

[48]  J F Antaki,et al.  Computational fluid dynamics as a development tool for rotary blood pumps. , 2001, Artificial organs.

[49]  J. Tarbell,et al.  Numerical simulation of unsteady laminar flow through a tilting disk heart valve: prediction of vortex shedding. , 1994, Journal of biomechanics.

[50]  A P Yoganathan,et al.  Fluid dynamic studies for the year 2000. , 1998, The Journal of heart valve disease.

[51]  S. Etoch,et al.  Current status of the AbioCor implantable replacement heart. , 2001, The Annals of thoracic surgery.

[52]  C S Peskin,et al.  A general method for the computer simulation of biological systems interacting with fluids. , 1995, Symposia of the Society for Experimental Biology.

[53]  J Jesty,et al.  Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: elimination of the feedback activation of platelets by thrombin. , 1999, Analytical biochemistry.

[54]  H. Stødkilde-Jørgensen,et al.  Three-Dimensional Visualization of Velocity Profiles in the Ascending Aorta in Humans. , 1988, The International journal of artificial organs.

[55]  N H Hwang,et al.  Estimation of the rotational undamped natural frequency of bileaflet cardiac valve prostheses. , 1990, Journal of biomechanical engineering.

[56]  L Zuckerman,et al.  Shear-induced activation of platelets. , 1979, Journal of biomechanics.

[57]  E. Eckstein,et al.  Transient lateral transport of platelet-sized particles in flowing blood suspensions. , 1994, Biophysical journal.

[58]  K B Chandran,et al.  Effect of prosthetic mitral valve geometry and orientation on flow dynamics in a model human left ventricle. , 1989, Journal of biomechanics.

[59]  O H Frazier,et al.  Surgery for Acquired Cardiovascular Disease Initial experience with the AbioCor Implantable Replacement Heart System , 2004 .

[60]  A. Gosman,et al.  Aspects of Computer Simulation of Liquid-Fueled Combustors , 1983 .

[61]  L H Edmunds,et al.  Is prosthetic valve thrombogenicity related to design or material? , 1996, Texas Heart Institute Journal.

[62]  S P Sutera,et al.  HEMOLYSIS AND SUBHEMOLYTIC ALTERATIONS OF HUMAN RBC INDUCED BY TURBULENT SHEAR FLOW , 1972, Transactions - American Society for Artificial Internal Organs.

[63]  N G Smedira,et al.  Clinical experience with long-term use of implantable left ventricular assist devices: indications, implantation, and outcomes. , 2000, Seminars in thoracic and cardiovascular surgery.

[64]  A. Gosman,et al.  Aspects of computer simulation of liquid-fuelled combustors , 1981 .

[65]  BARTLEY P. GRIFFITH,et al.  Long Term Animal Experiments With an Intraventricular Axial Flow Blood Pump , 1997, ASAIO journal.

[66]  J A Zivin,et al.  Detection of arterial emboli using Doppler ultrasound in rabbits. , 1991, Stroke.

[67]  M. Antunes Technique of Implantation of the Medtronic‐Hall Valve and Other Modern Tilting‐Disc Prostheses , 1990, Journal of cardiac surgery.

[68]  M. Kaps,et al.  Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses. , 1997, Circulation.

[69]  H Harasaki,et al.  Structural and left ventricular histologic changes after implantable LVAD insertion. , 1995, The Annals of thoracic surgery.

[70]  A. R. Twardock,et al.  A New Method for Quantitation of Platelet Microthrombi and Microemboli From Cardiopulmonary Bypass in Organs Using 111In Labeled Platelets , 1997, ASAIO journal.

[71]  Frensley,et al.  Non-Markovian open-system boundary conditions for the time-dependent Schrödinger equation. , 1994, Physical review. B, Condensed matter.

[72]  T. L. Cole,et al.  Isolation and study of an acquired inhibitor of human coagulation factor V. , 1986, The Journal of clinical investigation.

[73]  J D Hellums,et al.  Morphological, biochemical, and functional changes in human platelets subjected to shear stress. , 1975, The Journal of laboratory and clinical medicine.

[74]  J Fisher,et al.  Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve. , 1997, Medical engineering & physics.

[75]  D Kwak,et al.  Computational approach for probing the flow through artificial heart devices. , 1997, Journal of biomechanical engineering.

[76]  H. Thoma,et al.  In vitro investigation of thrombogenesis in rotary blood pumps. , 2008, Artificial organs.

[77]  M. Antunes,et al.  Intermittent aortic regurgitation following aortic valve replacement with the Hall-Kaster prosthesis. , 1982, The Journal of thoracic and cardiovascular surgery.

[78]  J. Dawes,et al.  Platelet alpha granule depletion: findings in patients with prosthetic heart valves and following cardiopulmonary bypass surgery. , 1983, Thrombosis research.

[79]  J T Watson,et al.  The REMATCH trial: rationale, design, and end points. Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure. , 1999, The Annals of thoracic surgery.

[80]  A P Yoganathan,et al.  The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus. , 2001, The Journal of heart valve disease.

[81]  E. Butchart,et al.  Anticoagulation variability between centres: implications for comparative prosthetic valve assessment. , 1988, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[82]  V. Björk Optimal orientation of the 60 degrees and the 70 degrees Björk-Shiley tilting disc valves. , 1982, Scandinavian journal of thoracic and cardiovascular surgery.

[83]  J D Hellums,et al.  Response of human platelets to sheer stress. , 1975, Transactions - American Society for Artificial Internal Organs.

[84]  J M Anderson,et al.  Directions for improvement of substitute heart valves: National Heart, Lung, and Blood Institute's Working Group report on heart valves. , 1997, Journal of biomedical materials research.

[85]  K. Riemslagh,et al.  A Three-dimensional Analysis of Flow in the Pivot Regions of an ATS Bileaflet Valve , 1999, The International journal of artificial organs.

[86]  H Schmid-Schönbein,et al.  Towards a concept of thrombosis in accelerated flow: rheology, fluid dynamics, and biochemistry. , 1985, Biorheology.

[87]  D Morley,et al.  Clinical experience with nine patients supported by the continuous flow Debakey VAD. , 2001, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[88]  James F. Antaki,et al.  Computational Simulation of Platelet Deposition and Activation: II. Results for Poiseuille Flow over Collagen , 1999, Annals of Biomedical Engineering.

[89]  A bovine model for detecting high intensity transient signals originating from mechanical heart valves. , 1999 .

[90]  I. Reinvang,et al.  Association between intraoperative cerebral microembolic signals and postoperative neuropsychological deficit: comparison between patients with cardiac valve replacement and patients with coronary artery bypass grafting , 1998, Journal of neurology, neurosurgery, and psychiatry.

[91]  K. V. Hall Surgical Considerations for Avoiding Disc Interference Based on A Ten‐year Experience with the Medtronic Hall Heart Valve , 1988, Journal of cardiac surgery.

[92]  A. Goodall,et al.  Evaluation of Whole Blood Flow Cytometric Detection of Platelet Bound Fibrinogen on Normal Subjects and Patients with Activated Platelets , 1993, Thrombosis and Haemostasis.

[93]  L. Edmunds,et al.  Thrombotic and bleeding complications of prosthetic heart valves. , 1987, The Annals of thoracic surgery.

[94]  P. Despland,et al.  The matching pursuit: a new method of characterizing microembolic signals? , 2000, Ultrasound in medicine & biology.

[95]  S. Einav,et al.  A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. , 1994, Journal of biomechanics.

[96]  Tom G Mackay,et al.  On the origin of cerebrovascular microemboli associated with prosthetic heart valves. , 1995, Neurological research.

[97]  Markus J. Wilhelm,et al.  Treatment of Thrombus Formation Associated With the MicroMed DeBakey VAD Using Recombinant Tissue Plasminogen Activator , 2002, Circulation.

[98]  M. Perthel,et al.  Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes. , 2000, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[99]  M Kaps,et al.  Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves. , 1997, Stroke.

[100]  Steven M. Slack,et al.  Fluid Dynamic and Hemorheologic Considerations , 1993 .

[101]  M. Kaps,et al.  Transcranial Doppler detection of microemboli in prosthetic heart valve patients: dependency upon valve type. , 1996, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[102]  A. Beaudoin,et al.  Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis. , 1993, The American journal of physiology.

[103]  S. Wisniewski,et al.  Measurement of hemostatic indexes in conjunction with transcranial doppler sonography in patients with ventricular assist devices. , 1999, Stroke.

[104]  Danny Bluestein,et al.  Flow-Induced Platelet Activation in Bileaflet and Monoleaflet Mechanical Heart Valves , 2004, Annals of Biomedical Engineering.

[105]  R. Baumgartner,et al.  Venous Microemboli in Patients with Artificial Heart Valves , 1999, Cerebrovascular Diseases.

[106]  U Losert,et al.  Minimization of Hemolysis in Centrifugal Blood Pumps: Influence of Different Geometries , 1993, The International journal of artificial organs.

[107]  A. Fraser,et al.  A New Scoring System to Determine Thromboembolic Risk After Heart Valve Replacement , 2003, Circulation.

[108]  H. Reul,et al.  In Vitro Blood Damage by High Shear Flow: Human versus Porcine Blood , 2002, The International journal of artificial organs.

[109]  C S Peskin,et al.  Fluid dynamics of the mitral valve: physiological aspects of a mathematical model. , 1982, The American journal of physiology.

[110]  H Reul,et al.  Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. , 2001, Artificial organs.

[111]  M Grigioni,et al.  The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves. , 2001, Journal of biomechanics.

[112]  Ajit P Yoganathan,et al.  An analysis of turbulent shear stresses in leakage flow through a bileaflet mechanical prostheses. , 2002, Journal of biomechanical engineering.

[113]  D. Slaaf,et al.  Real-Time Detection of Activation Patterns in Individual Platelets during Thromboembolism in vivo: Differences between Thrombus Growth and Embolus Formation , 2002, Journal of Vascular Research.

[114]  C S Peskin,et al.  Computer-assisted design of butterfly bileaflet valves for the mitral position. , 1985, Scandinavian journal of thoracic and cardiovascular surgery.

[115]  A. Fogelson,et al.  Surface-mediated control of blood coagulation: the role of binding site densities and platelet deposition. , 2001, Biophysical journal.

[116]  R M Hochmuth,et al.  Shear-induced aggregation and lysis of platelets. , 1976, Transactions - American Society for Artificial Internal Organs.

[117]  M. Spencer,et al.  Detection of microemboli in patients with artificial heart valves using transcranial Doppler: preliminary observations. , 1993, The Journal of heart valve disease.

[118]  R. Dewall,et al.  Implantation techniques: a primary consideration in valve surgery. , 1989, The Annals of thoracic surgery.

[119]  J. D. Hellums,et al.  A New Role for P-Selectin in Shear-Induced Platelet Aggregation , 2000, Circulation.

[120]  G Wieselthaler,et al.  Mechanically induced blood trauma: are the relevant questions already solved, or is it still an important field to be investigated? , 1995, Artificial organs.

[121]  P. Comfurius,et al.  Mechanisms involved in platelet procoagulant response. , 1993, Advances in experimental medicine and biology.

[122]  Larry V. McIntire,et al.  Real-time analysis of shear-dependent thrombus formation and its blockade by inhibitors of von Willebrand factor binding to platelets. , 1993 .

[123]  Samer A. Kseibi,et al.  Impact of high intensity transient signals on the choice of mechanical aortic valve substitutes. , 2003, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[124]  K. Mann,et al.  Human prothrombinase complex assembly and function on isolated peripheral blood cell populations. , 1985, The Journal of biological chemistry.

[125]  D J Wheatley,et al.  Detection of microemboli by transcranial Doppler ultrasound. , 1996, Texas Heart Institute journal.

[126]  A P Yoganathan,et al.  Turbulent shear stress measurements in the vicinity of aortic heart valve prostheses. , 1986, Journal of biomechanics.

[127]  S. Sutera,et al.  A programmable, computer-controlled cone-plate viscometer for the application of pulsatile shear stress to platelet suspensions. , 1988, Biorheology.

[128]  E. Eckstein,et al.  An estimated shape function for drift in a platelet-transport model. , 1994, Biophysical journal.

[129]  G. Tuszynski,et al.  Thrombospondin promotes platelet aggregation. , 1988, Blood.

[130]  H Nygaard,et al.  Orientation of tilting disc and bileaflet aortic valve substitutes for optimal hemodynamics. , 1999, The Annals of thoracic surgery.

[131]  J. Moake,et al.  Platelets and shear stress. , 1996, Blood.

[132]  Edmunds Lh,et al.  Is prosthetic valve thrombogenicity related to design or material , 1996 .