공동주택 세대 간벽-발코니 외벽 접합부의 적정 평면 단열상세에 관한 연구 ( A Study on the Optimal Plane Insulation Detail of the Household Partition Wall-Balcony Exterior Wall Joint of Apartment Building )

The regions of joints in an apartment building envelope are apt to be thermal bridges. To improve the insulation performance of these regions, optimal insulation details should be applied. In this study, optimal plane insulation detail of the household partition wall-balcony exterior wall joint is suggested after the evaluation of surface condensation and its life cycle cost. As a result, the effects of thermal bridging are reduced and its life cycle cost is minimized.