Evaluation of an Electronic Device for Real-Time Measurement of Alcohol-Based Hand Rub Use

Background. Observational surveys of hand hygiene compliance are time consuming. Measuring the use of a hand hygiene product is a less time-consuming method of monitoring the frequency of hand hygiene performance. Objective. To evaluate the usefulness of electronic devices for monitoring alcohol-based hand rub use. Design. Prospective observational trial. Setting. A university-affiliated teaching hospital. Methods. Prototypes of an electronic device designed to record each time a dispenser is used (hereafter referred to as a hand hygiene event) were placed in alcohol-based hand rub dispensers on the general medical ward and in the surgical intensive care unit. Data were downloaded wirelessly to a data logger and then uploaded to a dedicated Web site for analysis. Alcohol-based hand rub dispensers were located in patient rooms and in corridors. Results. During a 6-month trial, 105,462 hand hygiene events occurred in the surgical intensive care unit, and 44,845 events occurred on the general medical ward. The dispensers located in patient rooms accounted for 47% of the hand hygiene events performed in the surgical intensive care unit but for only 36% of events on the general medical ward (P<.001). The dispensers most often used were located in corridors. Hand hygiene events were most common on Tuesdays, Wednesdays, and Thursdays, between 7:00 AM and 11:00 AM. Conclusions. The use of these electronic devices provided an efficient and accurate method of monitoring the frequency of alcohol-based hand rub performance on the general medical ward and in the surgical intensive care unit, and yielded more detailed information on usage patterns than did expressing use as liters per 1,000 patient-days. The wireless downloading of data from dispensers required a limited amount of time, and the dedicated Web site facilitated data analysis. Such devices should prove useful in monitoring the impact of various interventions on the frequency of hand hygiene performance.

[1]  T. Eckmanns,et al.  Hand rub consumption and hand hygiene compliance are not indicators of pathogen transmission in intensive care units. , 2006, The Journal of hospital infection.

[2]  R. Salcido,et al.  Evaluation of a patient education model for increasing hand hygiene compliance in an inpatient rehabilitation unit. , 2004, American journal of infection control.

[3]  Didier Pittet,et al.  Guideline for Hand Hygiene in Health-Care Settings. Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. Society for Healthcare Epidemiology of America/Association for Professionals in Infection Control/Infectious Dis , 2002, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.

[4]  Philippe Mourouga,et al.  Compliance with Handwashing in a Teaching Hospital , 1999, Annals of Internal Medicine.

[5]  David W Bates,et al.  Safety of patients isolated for infection control. , 2003, JAMA.

[6]  Elaine L. Larson,et al.  An Organizational Climate Intervention Associated With Increased Handwashing and Decreased Nosocomial Infections , 2000, Behavioral medicine.

[7]  J. Boyce,et al.  Lack of Association Between the Increased Incidence of Clostridium difficile–Associated Disease and the Increasing Use of Alcohol-Based Hand Rubs , 2006, Infection Control &#x0026; Hospital Epidemiology.

[8]  Barrie C Mayall,et al.  Efficacy of an alcohol/chlorhexidine hand hygiene program in a hospital with high rates of nosocomial methicillin‐resistant Staphylococcus aureus (MRSA) infection , 2005, The Medical journal of Australia.

[9]  Didier Pittet,et al.  Guideline for Hand Hygiene in Health-Care Settings. Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HIPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. , 2002, American journal of infection control.

[10]  S. Hugonnet,et al.  Effectiveness of a hospital-wide programme to improve compliance with hand hygiene , 2000, The Lancet.

[11]  K. Kirkland,et al.  Adverse effects of contact isolation , 1999, The Lancet.

[12]  Didier Pittet,et al.  Guideline for Hand Hygiene in Health-Care Settings Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC / SHEA / APIC / IDSA Hand Hygiene Task Force , 2002 .

[13]  E. Larson,et al.  Hand hygiene behavior in a pediatric emergency department and a pediatric intensive care unit: comparison of use of 2 dispenser systems. , 2005, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[14]  J. Haas,et al.  Measurement of compliance with hand hygiene. , 2007, The Journal of hospital infection.

[15]  C. Marshman,et al.  An automatic monitoring system for measuring handwashing frequency in hospital wards. , 1984, The Journal of hospital infection.

[16]  Arjun K Venkatesh,et al.  Use of electronic alerts to enhance hand hygiene compliance and decrease transmission of vancomycin-resistant Enterococcus in a hematology unit. , 2008, American journal of infection control.

[17]  T. F. van de Mortel,et al.  An examination of covert observation and solution audit as tools to measure the success of hand hygiene interventions. , 2006, American journal of infection control.