Squeezed Trajectory Design for Peak RF and Integrated RF Power Reduction in Parallel Transmission MRI

High peak RF amplitude and excessive specific absorption rate (SAR) are two critical concerns for hardware implementation and patient safety in scientific and clinical research for high field MRI using parallel transmissions (pTX). In this paper, we introduce a squeezing strategy to reduce peak RF amplitude and integrated RF power via direct reshaping of the k-space trajectory. In the existing peak RF / integrated RF power optimization methods gradient amplitude or slew rate is reduced, but the k-space trajectory remains unchanged. Unlike these traditional methods, we worked directly in the excitation k-space to reshape k-space traversal by a squeezing vector in order to achieve peak RF and total RF power optimization, using a particle swarm optimization algorithm. The squeezing strategy was applied to the conventional variable density spiral (CVDS) and the variable rate selective excitation (VERSE) trajectories, dubbed SVDS (squeezed variable density spiral) and SVERSE (squeezing trajectory with VERSE), respectively, for different excitation profiles of small or large tip angles. Pulse acceleration and off-resonance effects were evaluated for an 8-ch pTX via Bloch simulation. CVDS, VERSE, SVDS, and SVERSE pulses were implemented on a 3T scanner with a 2-ch pTX. Phantom and in vivo experiments were performed for reduced FOV (rFOV) imaging. The results show that SVDS pulses simultaneously reduce integrated RF power and peak RF by about 30% on average compared to CVDS pulses for a square pattern ( $80\times80$ mm2) with flip angles of 30°, 90°, and 180°. Compared with the VERSE method under the same peak RF constraints, the SVDS method reduces integrated RF power by an average of 20% for small tip excitations for profiles of slice, rectangular, square, and circle, and has slightly reduced excitation accuracy slightly (about 0.6%, from 6.8% to 7.4%). The SVERSE method shortens the duration of the VERSE pulse by 12.8% at large ti p angle (180°). Feasibility for rFOV imaging was demonstrated with phantom and in vivo experiments with squeezed pulses.

[1]  Seung-Jean Kim,et al.  A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories , 2008, IEEE Transactions on Medical Imaging.

[2]  Peter Andersen,et al.  Adapted RF pulse design for SAR reduction in parallel excitation with experimental verification at 9.4 T. , 2010, Journal of magnetic resonance.

[3]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[4]  Ke Feng,et al.  Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study. , 2008, Magnetic resonance imaging.

[5]  Douglas C Noll,et al.  Additive angle method for fast large‐tip‐angle RF pulse design in parallel excitation , 2008, Magnetic resonance in medicine.

[6]  J. Lagendijk,et al.  7 T body MRI: B1 shimming with simultaneous SAR reduction , 2007, Physics in medicine and biology.

[7]  Lothar R. Schad,et al.  Fast and Robust Design of Time-Optimal k-Space Trajectories in MRI , 2015, IEEE Transactions on Medical Imaging.

[8]  Abdellatif Mtibaa,et al.  Real-time synchronous hardware architecture for MRI images segmentation based on PSO , 2015, 2015 4th International Conference on Systems and Control (ICSC).

[9]  Chung-I G. Hsu,et al.  Techniques of evaluating high impedance surfaces used for SAR reduction , 2010, 2010 Asia-Pacific International Symposium on Electromagnetic Compatibility.

[10]  Lawrence L Wald,et al.  Fast three‐dimensional inner volume excitations using parallel transmission and optimized k‐space trajectories , 2016, Magnetic Resonance in Medicine.

[11]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[12]  Zhi-Pei Liang,et al.  Variable slew‐rate spiral design: Theory and application to peak B1 amplitude reduction in 2D RF pulse design , 2007, Magnetic resonance in medicine.

[13]  Y. Zhu,et al.  Sparse Parallel Transmit Excitation Trajectory Design for Rapid Inner-Volume Excitation , 2010 .

[14]  Satish Chandra,et al.  A PSO based method for detection of brain tumors from MRI , 2009, 2009 World Congress on Nature & Biologically Inspired Computing (NaBIC).

[15]  T. Ibrahim,et al.  Analysis of B1 field profiles and SAR values for multi-strut transverse electromagnetic RF coils in high field MRI applications. , 2001, Physics in medicine and biology.

[16]  Ling Xia,et al.  A New Particle Swarm Optimization-Based Method for Phase Unwrapping of MRI Data , 2012, Comput. Math. Methods Medicine.

[17]  B. Hargreaves,et al.  Variable‐rate selective excitation for rapid MRI sequences , 2004, Magnetic resonance in medicine.

[18]  Peter Börnert,et al.  Parallel RF transmission in MRI , 2006, NMR in biomedicine.

[19]  Russell C. Eberhart,et al.  Solving Constrained Nonlinear Optimization Problems with Particle Swarm Optimization , 2002 .

[20]  Dwight G Nishimura,et al.  Introduction to: A k-space analysis of small-tip-angle excitation. , 2011, Journal of magnetic resonance.

[21]  Liansheng Zhang,et al.  A filled function method for global optimization , 2007 .

[22]  A. V. Levy,et al.  The Tunneling Algorithm for the Global Minimization of Functions , 1985 .

[23]  Douglas C Noll,et al.  Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off‐resonance , 2012, Magnetic resonance in medicine.

[24]  Ling Xia,et al.  Design of Shimming Rings for Small Permanent MRI Magnet Using Sensitivity-Analysis-Based Particle Swarm Optimization Algorithm , 2015 .

[25]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[26]  Douglas C Noll,et al.  Spatial domain method for the design of RF pulses in multicoil parallel excitation , 2006, Magnetic resonance in medicine.

[27]  Maurice Clerc,et al.  The particle swarm - explosion, stability, and convergence in a multidimensional complex space , 2002, IEEE Trans. Evol. Comput..

[28]  Zhi-Pei Liang,et al.  Joint design of spoke trajectories and RF pulses for parallel excitation , 2011, Magnetic resonance in medicine.

[29]  J. Hajnal,et al.  Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy , 2006, Magnetic resonance in medicine.

[30]  Adam B Kerr,et al.  VERSE‐guided numerical RF pulse design: A fast method for peak RF power control , 2012, Magnetic resonance in medicine.

[31]  O Speck,et al.  SAR simulations for high‐field MRI: How much detail, effort, and accuracy is needed? , 2013, Magnetic resonance in medicine.

[32]  Michael B. Smith,et al.  Reducing SAR and enhancing cerebral signal‐to‐noise ratio with high permittivity padding at 3 T , 2011, Magnetic resonance in medicine.

[33]  Kawin Setsompop,et al.  Parallel RF transmission with eight channels at 3 Tesla , 2006, Magnetic resonance in medicine.

[34]  Michael Lustig,et al.  Time‐optimal design for multidimensional and parallel transmit variable‐rate selective excitation , 2009, Magnetic resonance in medicine.

[35]  Klaas P. Pruessmann,et al.  VERSE‐guided parallel RF excitations using dynamic field correction , 2017, NMR in biomedicine.

[36]  D Le Bihan,et al.  kT‐points: Short three‐dimensional tailored RF pulses for flip‐angle homogenization over an extended volume , 2012, Magnetic resonance in medicine.

[37]  Ashok Panigrahy,et al.  MRI evaluation and safety in the developing brain. , 2015, Seminars in perinatology.

[38]  I. Introduction,et al.  An Overview of PSO- Based Approaches in Image Segmentation , 2012 .

[39]  Koetsu Yamazaki,et al.  Penalty function approach for the mixed discrete nonlinear problems by particle swarm optimization , 2006 .

[40]  Douglas C Noll,et al.  Joint design of trajectory and RF pulses for parallel excitation , 2007, Magnetic resonance in medicine.

[41]  Vivek K. Goyal,et al.  Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design , 2008, IEEE Transactions on Medical Imaging.

[42]  Jeffrey A. Fessler,et al.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI , 2016, IEEE Transactions on Medical Imaging.

[43]  Elfar Adalsteinsson,et al.  Local SAR in parallel transmission pulse design , 2011, Magnetic resonance in medicine.