Rapid determination of ETS markers with a prototype field-portable GC employing a microsensor array detector.

The adaptation of a portable gas chromatograph (GC) prototype with several unique design features to the determination of vapor-phase markers of environmental tobacco smoke (ETS) is described. This instrument employs a dual-stage adsorbent preconcentrator, two series-coupled separation columns that can be independently temperature programmed, and a detector consisting of an array of nanoparticle-coated chemiresistors, whose response patterns are used together with retention times for vapor recognition. An adsorbent pre-trap was developed to remove semi-volatile organics from the sample stream. Conditions were established to quantitatively capture two ETS markers, 2,5-dimethylfuran (2,5-DMF) and 4-ethenylpyridine (4-EP, as a surrogate for 3-EP), and to separate them from the 34 most prominent co-contaminants present in ETS using ambient air as the carrier gas. A complete analysis can be performed every 15 min. Projected detection limits are 0.58 and 0.08 ppb for 2,5-DMF and 4-EP, respectively, assuming a 1 L sample volume, which are sufficiently low to determine these markers in typical smoking-permitted environments.

[1]  E. Zellers,et al.  A dual-adsorbent preconcentrator for a portable indoor-VOC microsensor system. , 2001, Analytical chemistry.

[2]  Chia-Jung Lu,et al.  A vapor selectivity study of microsensor arrays employing various functionalized ligand protected gold nanoclusters , 2006 .

[3]  L. E. Alevantis,et al.  Use of volatile tracers to determine the contribution of environmental tobacco smoke to concentrations of volatile organic compounds in smoking environments , 2008 .

[4]  Jan Dziuban,et al.  Portable gas chromatograph with integrated components , 2004 .

[5]  Cagliyan Kurdak,et al.  Single-Phase Synthesis of Functionalized Gold Nanoparticles , 2004 .

[6]  K. Wise,et al.  First-generation hybrid MEMS gas chromatograph. , 2005, Lab on a chip.

[7]  S. Baek,et al.  Performance Evaluation of Simultaneous Monitoring of Personal Exposure to Environmental Tobacco Smoke and Volatile Organic Compounds , 2001, Indoor and Built Environment.

[8]  E. Zellers,et al.  Limits of recognition for simple vapor mixtures determined with a microsensor array. , 2004, Analytical chemistry.

[9]  Jiamo Fu,et al.  Determination of tobacco smoking influence on volatile organic compounds constituent by indoor tobacco smoking simulation experiment , 2003 .

[10]  M. P. Maskarinec,et al.  Determination of exposure to environmental tobacco smoke in restaurant and tavern workers in one US city , 2000, Journal of Exposure Analysis and Environmental Epidemiology.

[11]  Y. Saint-Jalm,et al.  An international survey of indoor air quality, ventilation, and smoking activity in restaurants: a pilot study , 2003, Journal of Exposure Analysis and Environmental Epidemiology.

[12]  M. W. Ogden,et al.  Effect of ventilation and sampling time on environmental tobacco smoke component ratios , 1992 .

[13]  Chia-Jung Lu,et al.  Portable gas chromatograph with tunable retention and sensor array detection for determination of complex vapor mixtures. , 2003, Analytical chemistry.

[14]  Product Review: GC To Go , 2002 .

[15]  E. Zellers,et al.  Vapor recognition with small arrays of polymer-coated microsensors. A comprehensive analysis. , 1999, Analytical chemistry.

[16]  Elisabeth L. Hawley,et al.  Gas-phase organics in environmental tobacco smoke. 1. Effects of smoking rate, ventilation, and furnishing level on emission factors. , 2002, Environmental science & technology.

[17]  C. N. Davies Absorption of gases in the respiratory tract. , 1985, The Annals of occupational hygiene.

[18]  E. Zellers,et al.  Optimal coating selection for the analysis of organic vapor mixtures with polymer-coated surface acoustic wave sensor arrays. , 1995, Analytical chemistry.

[19]  E. Zellers,et al.  Characterization of polymeric surface acoustic wave sensor coatings and semiempirical models of sensor responses to organic vapors. , 1993, Analytical chemistry.

[20]  P A Smith,et al.  Towards smaller and faster gas chromatography-mass spectrometry systems for field chemical detection. , 2005, Journal of chromatography. A.

[21]  Chunrong Jia,et al.  Development and comparison of methods using MS scan and selective ion monitoring modes for a wide range of airborne VOCs. , 2006, Journal of environmental monitoring : JEM.

[22]  Qingyu Song,et al.  Handheld rectilinear ion trap mass spectrometer. , 2006, Analytical chemistry.

[23]  E. Zellers,et al.  Multi-adsorbent preconcentration/focusing module for portable-GC/microsensor-array analysis of complex vapor mixtures. , 2002, The Analyst.

[24]  K Reijula,et al.  Nicotine and 3-ethenylpyridine concentrations as markers for environmental tobacco smoke in restaurants. , 2000, Indoor air.

[25]  J. Pawliszyn,et al.  On-site environmental analysis by membrane extraction with a sorbent interface combined with a portable gas chromatograph system , 2005 .

[26]  P. J. Callahan,et al.  Volatile organic compounds as breath biomarkers for active and passive smoking. , 2002, Environmental health perspectives.

[27]  E. Zellers,et al.  Dual-chemiresistor GC detector employing monolayer-protected metal nanocluster interfaces. , 2002, Analytical chemistry.

[28]  E. Zellers,et al.  Chamber evaluation of a portable GC with tunable retention and microsensor-array detection for indoor air quality monitoring. , 2006, Journal of environmental monitoring : JEM.