A hybrid algorithm for fast detection and classification of voltage disturbances in electric power systems

To minimize the adverse impacts of power quality disturbances on the electric power supply as well as on the customer equipment, there is clearly a need for detection and classification of such problems. In this paper, a fast detection algorithm for power quality disturbances is presented. The proposed method is a hybrid of two algorithms, abc–0dq transformation and 908 phase shift algorithms. The proposed algorithm is fast and reliable in detecting most voltage disturbances in power systems such as voltage sags, voltage swells, interrupts, flicker, harmonics, etc. In the proposed approach, the three-phase utility voltages are sensed separately by each of the algorithms. These algorithms are combined to explore their individual strengths for a better performance. When a disturbance occurs, both algorithms work together to recognize this distortion and send trip signals to static transfer switches. This control method can be used for critical loads protection in case of utility voltage distortion. Simulation and analysis results obtained in this study illustrate high performance of the strategy in different single-phase and three-phase voltage distortions.

[1]  Fang Zheng Peng,et al.  Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems , 1996 .

[2]  M. Barnes,et al.  Voltage sag detection technique for a dynamic voltage restorer , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[3]  Michel Meunier,et al.  Detection and measurement of power quality disturbances using wavelet transform , 2000 .

[4]  P.N. Enjeti,et al.  A fast detection algorithm suitable for mitigation of numerous power quality disturbances , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[5]  Salvatore Nuccio,et al.  A self-synchronizing instrument for harmonic sources detection in power systems , 2003, Proceedings of the 20th IEEE Instrumentation Technology Conference (Cat. No.03CH37412).

[6]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[7]  J. Svensson Synchronisation methods for grid-connected voltage source converters , 2001 .

[8]  G. T. Heydt A New Method for the Calculation of Subtransmission and Distribution System Transients Based on the FFT , 1989, IEEE Power Engineering Review.

[9]  D. J. Adams,et al.  Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems , 1998 .

[10]  M. R. Iravani,et al.  Experimental Performance Evaluation of a Wavelet-Based on-Line Voltage Detection Method for Power Quality Applications , 2001, IEEE Power Engineering Review.

[11]  A. Y. Chikhani,et al.  Genetic Algorithms Based Economic Dispatch for Cogeneration Units Considering Multiplant , 2022 .

[12]  Y.-J. Shin,et al.  Power quality indices for transient disturbances , 2006, IEEE Transactions on Power Delivery.

[13]  H. P. Stern,et al.  Efficient dynamic synchronous machine simulation with harmonics , 1996 .

[14]  Mudathir Funsho Akorede,et al.  Wavelet Transforms: Practical Applications in Power Systems , 2009 .

[15]  M.R. Iravani,et al.  A signal Processing system for extraction of harmonics and reactive current of single-phase systems , 2004, IEEE Transactions on Power Delivery.