Smart grids : general review of synchronization techniques

This paper deals with crucial aspect of synchronization in modern power grids. It presents the concept of intelligent networks (“smart grids”), as the future of today’s grid infrastructure. The diversity of different grid codes in regards to the synchronization requirements for different Transmission System Operators (TSO) is discussed. This paper shows the applications of synchronizing algorithms, their role in power grid system.. The methods are classified according to application, the reference frame used and the possibility of using them in single and three phase systems. Proper selection of synchronization algorithms to meet the requirements of TSO’s calls for creation of appropriate evaluation methods. For this reason, at the end of the article quality criteria for the evaluation of synchronizing algorithms were proposed and explained in detail. Finally, the last section states what are the most commonly used methods for grid synchronization.

[1]  Xu Dianguo,et al.  A novel PLL design method applied to grid fault condition , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[2]  E.A.A. Coelho,et al.  PLL Structures for Utility Connected Systems under Distorted Utility Conditions , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[3]  Wojciech Jarzyna,et al.  The comparison of Polish grid codes to certain European standards and resultant differences for WPP requirements , 2013, 2013 15th European Conference on Power Electronics and Applications (EPE).

[4]  S.A. Mussa,et al.  Digital control based on DPLL of an AC line conditioner , 2008, 2008 IEEE Power Electronics Specialists Conference.

[5]  F. Blaabjerg,et al.  Spectral analysis of instantaneous powers in single-phase and three-phase systems with use of p-q-r theory , 2002 .

[6]  Birgitte Bak-Jensen,et al.  Instantaneous power compensation in three-phase systems by using p-q-r theory , 2002 .

[7]  Marian P. Kazmierkowski,et al.  Grid synchronization and symmetrical components extraction with PLL algorithm for grid connected power electronic converters - a review , 2011 .

[8]  Grzegorz Benysek,et al.  Power electronic systems as a crucial part of Smart Grid infrastructure - a survey , 2011 .

[9]  Yang Han On Using ADALINE Algorithm for Harmonic Estimation and Phase-Synchronization for the Grid-Connected Converters in Smart Grid Applications , 2013 .

[10]  Jon Are Suul,et al.  Control of Grid Integrated Voltage Source Converters under Unbalanced Conditions : Development of an On-line Frequency-adaptive Virtual Flux-based Approach , 2012 .

[11]  S.M. Silva,et al.  Wide bandwidth single and three-phase PLL structures for grid-tied PV systems , 2000, Conference Record of the Twenty-Eighth IEEE Photovoltaic Specialists Conference - 2000 (Cat. No.00CH37036).

[12]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[13]  S.M. Silva,et al.  PLL structures for utility connected systems , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[14]  Marco Liserre,et al.  PLL Algorithm for Power Generation Systems Robust to Grid Voltage Faults , 2006 .

[15]  Seung-Ki Sul,et al.  Reference wave generation in dynamic voltage restorers by use of PQR power theory , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[16]  F. Blaabjerg,et al.  Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[17]  F. Profumo,et al.  Analysis and Comparison of Phase Locked Loop Techniques for Grid Utility Applications , 2007, 2007 Power Conversion Conference - Nagoya.

[18]  M.P. Kazmierkowski,et al.  New direct power control of three-phase PWM boost rectifiers under distorted and imbalanced line voltage conditions , 2003, 2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692).

[19]  Xiaoqiang Guo,et al.  Phase locked loop and synchronization methods for grid- interfaced converters: a review , 2011 .

[20]  R.A. Modesto,et al.  Single-phase PLL structure using modified p-q theory for utility connected systems , 2008, 2008 IEEE Power Electronics Specialists Conference.

[21]  J. Svensson Synchronisation methods for grid-connected voltage source converters , 2001 .

[22]  Masoud Karimi-Ghartemani,et al.  A novel three-phase magnitude-phase-locked loop system , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[23]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[24]  F.P. Marafao,et al.  Comparative analysis of Synchronization Algorithms based on PLL, RDFT and Kalman Filter , 2007, 2007 IEEE International Symposium on Industrial Electronics.

[25]  A. Rahmati,et al.  Direct Power Control of an VHDC system based on VSCs , 2006, 2006 IEEE International Conference on Industrial Technology.

[26]  Remus Teodorescu,et al.  Improved PLL structures for single-phase grid inverters , 2005 .

[27]  Dragan Jovcic,et al.  Phase locked loop system for FACTS , 2003 .

[28]  J. Malko „Smart” w energetyce – moda czy konieczność? , 2011 .

[29]  Ebrahim Abiri,et al.  A sensorless and simple controller for VSC based HVDC systems , 2009 .

[30]  G. Saccomando,et al.  Transient operation of grid-connected voltage source converter under unbalanced voltage conditions , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[31]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[32]  F. Blaabjerg,et al.  Spectral analysis of instantaneous powers in single-phase and three-phase systems with use of p-q-r theory , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[33]  Guan-Chyun Hsieh,et al.  Phase-locked loop techniques. A survey , 1996, IEEE Trans. Ind. Electron..

[34]  M. Liserre,et al.  Synchronization methods for three phase distributed power generation systems - An overview and evaluation , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[35]  Stephen J. Finney,et al.  Three-phase phase-lock loop for distorted utilities , 2007 .

[36]  Josep M. Guerrero,et al.  Design and Tuning of a Modified Power-Based PLL for Single-Phase Grid-Connected Power Conditioning Systems , 2012, IEEE Transactions on Power Electronics.

[37]  F. Blaabjerg,et al.  A Simple Sensorless Scheme for Induction Motor Drives Fed by a Matrix Converter Using Constant Air-Gap Flux and PQR Transformation , 2007 .

[38]  S.M. Silva,et al.  Performance evaluation of PLL algorithms for single-phase grid-connected systems , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[39]  Bimal K. Bose,et al.  Power Electronics and Motor Drives: Advances and Trends , 2006 .